HID Global 609XA User Manual

Installation Guide
iCLASS Reader Models R10, R30, R40, RW300, RW400
PARTS INCLUDE D SPECIFI CATIONS
1 -
iCLASS
1 - Installation Manual
2 - 3.5mm x .6 pitch x 12mm Phillips machine screws
3 - #6-32 x .375” Phillips self-tapping machine screws
2 - #6 x 1.5” Phillips sheet metal screws RS-232 - 50 ft (15m)
1 - #6 x .375” Spanner security screw, anti-tamper
Recomm ended:
Up to 9 wire splices
Cable, 5-9 conductor (Wieg. or RS232), 22awg shielded
Linear DC Power supply
Metal or plastic junction box
Magnetic switch - Ademco 945T, Sentrol 1038T, GRI 100T
or 110T or Aleph DC-2531
Security Tool (for anti-tamper screw) HID 04-0001-03 and other 3
INSTALLATION 1- Disassemble
Reader
R10 (Mullion)……………..10 - 16VDC / 65-225mA
R30/RW300 (Euro)………10 - 16VDC / 80-260mA
R40/RW400 (US)………...10 - 16VDC / 80-260mA
Cable distance to Host…..Wiegand - 500 feet (152m) max
Temperature………………-35° C to 65°C
Open collector output…….sink - 40mA, source - 1mA
Standards:
Read/Write* capability in ISO 15693-2 mode with HID
credentials
iCLASS
Read/Write* capability in ISO 14443-B2 mode with HID
16Ks and other 3
iCLASS
CSN read capability for ISO 14443-A1 with HID Mifare
rd
party Mifare credentials
rd
party credentials
* R10, R30, R40 are read-only
1- Remove Screw
2 - Lift Bottom of Bezel 4 - Lift top o f Reader Assembly 3 - Slide Bezel up and remove 5 - Slide down and remove
2- Install Tamper Switch
An internal magnet provides tamper indication when used with a magnetic reed switch connected to an external alarm system. (Except R10). Locate Switch behind the left side of the mounting plate, centered between the mounting holes.
Electrical Back Box
An ASSA ABLOY Group company
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com
™ Reader Installation Manual 6090-900 Rev 8 Page 1 of
Wall Su rfa c e
ASSA ABLOY
3
Installation Guide
iCLASS Reader Models R10, R30, R40, RW300, RW400
3- Prepari ng/Mounting
Install Mounting Plate to wall surface or back box, t hen reassemble reader (reverse Step 1 proc edure).
Dimensions are in inches (centimeters).
R10 Mounting Plate R30/RW300 Mounting Plate R40/RW400 Mounting Plate
4- Connecting 5- Testing
Turn Power On
Yellow *Speaker Blue *Hold Violet ***Open Collector Whit e Data 1 Green Data 0 Orange *Green LED Brown *Red LED Red +DC (10-16 VDC) Black Ground
Gray ***RX (Serial Receive) Red/Green ***DSR (Not Used)
Pink ***TX (Serial Transmit)
An ASSA ABLOY Group company
_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page - www.hidcorp.com e-mail – tech@hidcorp.com
speaker tones sequence.
Use a Test Card
Speaker tone for each card read.
6- Optional Features
RS232 interface/Host Mode -
serial link. See Protocol Document 6090-902 for information
Open Collector Output –
(13.8VDC Max) operating in Host Mode only. See Application Note for details
Configuration Options -
features. See How To Order Guide or Note for details
™ Reader Installation Manual 6090-900 Rev 8 Page 2 of
- watch the sign-on LED and hear the
- watch for the LED flash and hear the
for applications requiring a
controls an external device
iCLASS
Configure LED, Speaker, and other
Application
iCLASS
ASSA ABLOY
3
Loading...
+ 1 hidden pages