HID Global 6055BC Users manual

Page 1
REV APPROVED DATE DESCRIPTION
A
INITIAL RELEASE PER ECO ITG10324
.
REVISIONS
REV SHEET
REV STATUS
OF SHEETS
EXCEPT AS NOTED DIM ARE IN INCHES
PER ANSI Y14.5
.XX .XXX ANGLES +/-.01 +/-.005 +/-1
MATERIAL:
FINISH:
24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 47 48 49 50 51 52
REV SHEET
A A A A A 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
DO NOT SCALE DRAWING
APPROVALS DATE
DRW: ANDRESKY CHK: C. SHEA APVD: R. OKUDA APVD: R. GREEN
11/29/00 062501 071401 071301
DWG DESCRIPTION
IRVINE, CALIFORNIA
MANUAL, INSTALL,
READER
SHEET: 0 of 4 SCALE: N/A
SIZE
A
HID MIFARE
CAGE CODE DWG NUMBER
REV
A.0
Page 2
Install Manual – 6055-914 Rev A 6055C HID MIFARE
Reader
_________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949)598-1600 (800)237-7769 FAX (949)598-1690 Internet - www.hidcorp.com - HID Mifare Reader Installation Manual 6055-914 Rev A.0 Page 1 of 4
Page 3
1 Parts List
PARTS LIST (Included) Quantity
- HID MIFARE Reader with snap-on cover and 18in.
- #6-32 x 1” self-tapping panhead screw
- Installation manual 1
PARTS LIST (Not-Included) Quantity
- Wire splice 9
- DC Power supply 12 VDC 1
1 2
2 Mounting Instructions
Determine an appropriate mounting location. The
reader may be mounted to any surface, including metal.
Drill two (2) 3/32-inch (2.5mm) holes
approximately 1 inch deep for mounting the reader.
Drill a 5/8-inch (16mm) hole for the cable. A single-gang (2S) electrical junction box may
also be used; reader fits US hole pattern, and the 6-32 screws work with the J-box.
Remove the snap-on cover from the reader and
secure the reader to the mounting surface.
Route the cable from the reader and/or power
supply to the host. A linear type power supply is recommended. Check all electrical codes for proper cable installation.
For the cable connection to the panel - use Alpha
#1299C or equivalent.
Test the operation of the reader (Section 4). After
completion of the test, replace the snap-on cover.
See Figure 1 for product and mounting
dimensions.
For proper regulatory compliance, the drain wire
should be disconnected at the power supply end of the cable.
Changes or modifications not expressly approved
by the party responsible for compliance could void the user’s authority to operate the equipment.
The Reader is intended to be powered from a
limited power source output of a previously certified power supply.
3 Connecting the Reader
Connect the reader to the host according to the
wiring table below and the host installation guide.
Signal Color DB9F DB25F
9-14 VDC Red - ­GND Black Pin 5 Pin 7 D0 Green - ­D1 White - ­GRN LED Orange - ­RED LED Brown - ­Beeper HOLD DSR RX DTR TX SHLD GND
Yellow Blue Violet Pink Gray Tan Drain
­Pin 1
­Pin 2 Pin 4 Pin 3
-
­Pin 8
­Pin 3 Pin 20 Pin 2
-
4 Testing and Operation
When power is applied to the reader the beeper
will beep and flash the LED green three times.
Present an ID card to the reader. The LED will
momentarily turn green while the beeper beeps once, indicating that the card was read successfully.
Please note that typical read range for MIFARE
cards is .75 to 1.5” (20 – 37 mm).
Important Product Specifications
Power supply Absolute Maximum Voltage Maximum Current at 12V Operating Voltage Range
Maximum cable distance To host
Operating temperature range
FCC Compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Linear type 16 VDC 94mA
9.0 – 14.0 VDC 50 ft RS-232
500 ft Wiegand
-30 to 65C
_________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949)598-1600 (800)237-7769 FAX (949)598-1690 Internet - www.hidcorp.com - HID Mifare Reader Installation Manual 6055-914 Rev A.0 Page 2 of 4
Page 4
5 Card Compatibility
In the default configuration, the HID MIFARE
Reader reads HID-encoded OEM Card Data (Wiegand data) from these cards:
HID MIFARE Card, Model 1430 HID MIFARE/Prox, Model 1431 (dual
technology)
Any Philips compatible MIFARE Standard
contactless smart card.
The HID MIFARE reader will not read 125 kHz
HID Proximity cards.
The reader will only output HID-encoded OEM
Wiegand data from cards encoded with matching proprietary HID keys. Cards can either be encoded at the factory, or by using an available HID MIFARE Field Programmer.
The reader will read the MIFARE Card Serial
Number only from MIFARE Lite and MIFARE Pro cards. These cards are not available with Factory-encoded HID Card Data.
6 Reader Operation
There are two basic modes of reader operation:
Security Mode (the default mode) and Transaction Mode.
Security Mode
Security Mode is for use in Access Control and
parking applications. In security mode, the reader looks for two types of data on the card:
HID Factory encoded OEM format card data  Mifare Card Serial Number (CSN)
The reader may be configured in one of the
following Card Read Modes:
HID Card Data Only (default mode)  Mifare CSN Only  HID Card Data first, then look for CSN
In HID-Only Mode, when a card is presented, the
HID MIFARE Reader will look for HID-Encoded OEM card data in Sector 1 as well as the MIFARE Application Directory. Data is output in standard Wiegand format, exactly as it is encoded on the Mifare card, and it is also output on the serial port. The reader can also be field-
configured to look for HID-encoded OEM card data in a specific sector other than Sector 1.
In CSN Only mode, the reader reads the 32-bit
MIFARE random card serial number (CSN or UID) from any MIFARE card, including MIFARE Lite, MIFARE Standard and MIFARE Pro, outputting that data in a Wiegand format. MIFARE CSN Data is output via the Wiegand port per the reader’s configuration to one of the following CSN Output Modes:
32-bit Philips standard, MSB first (default) 32-bit Reverse Order (6055A compatible)  26-bit format (32-bit, truncated to 16 LSB, 8-
bit FC defaulted to 1, B/E parity) - FC may be user-configured)
34-bit, Philips Standard + B/E parity  40-bit format - 32-bit CSN + 8 bit checksum
In HID+CSN mode, the reader first checks all
possible locations for HID OEM data, and if no HID data is found, it outputs the CSN.
Card Read Mode and CSN Output Mode can be
ordered pre-configured at the factory, or may be field-configured with Command Cards.
Consult HID Technical Support for information on
obtaining Command cards or for additional details on configuration options.
Transaction Mode
The reader can also communicate via the serial
port for non-access control applications, including read-write capability. When in transaction mode, the reader asserts the DTR line to alert the Host that a card ID is outputting, and it will continue to output repeatedly until acknowledged by the host controller. Configuration to Transaction Mode is accomplished by a command from the Host via the serial port. No command card is required, and no special factory configuration is required.
A Software Development Kit is available – please
contact your dealer for details.
_________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949)598-1600 (800)237-7769 FAX (949)598-1690 Internet - www.hidcorp.com - HID Mifare Reader Installation Manual 6055-914 Rev A.0 Page 3 of 4
Page 5
4
0
3.000
.68
.02
4.700
7
.125
3.280