HID Global 6015 User Manual

TM
This devi ce complies with part 15 of the FCC
may cause u ndesired o peration.
interferenc e recieved , includi ng interferen ce that
condition s: (1) This device may not cause harmful
rules. Operati on is sub ject to the following t wo
1998 HID CORPORATION
U.S. PATENT NO. 4,730,18 8 5,041,62 5
C
FCC ID: JQ66015
ELECTRICAL RATING: 10.8-13. 2VDC/250mA
REFER TO OPERATORS MANUAL 6015-900.
ACCESS CONTROL SYSTEM UNIT ACCESSORY.
8T29
R
LISTED
HID CORPORATION
4
.
0
0
4
.
0
0
AMR100 Property Pass Reader Installation Manual (6015-900) Installation Requirements
The following instructions will explain the installation and operation procedure for the AMR100 Property Pass Reader. The instructions include these sections:
Installation Instructions
Mounting Preparation Cabling Preparation Mounting O-Ring Switch Settings Jumper Settings Power Supply Cover Installation
AMR100 Property Pass Reader
Parts List (Included) Quantity
1) AMR100 Property Pass Reader 1
2) O-ring - 12"diameter x .25" thick 1
3) #6-32x.625 Flathead Screw 1
4) Installation Manual 1
5) Front Cover Label 1
6) Strain Relief Nut 2
Parts List (NOT Included)
1) External 12V power supply 1
2) #6 Mounting Screws A/R
3) Cable (See requirements below) A/R
Cabling Requirements Shielded
Power & Ground - 18AWG- 22AWG All other signals - 24 AWG minimum Strain Relief Nut cable range: .19 to .390
11.80 1.00
Place screw to secure top cover here.
HID ProxTrak
11.80
Figure 1
Installation Instructions
Mounting Preparation
1. Determine an appropriate mounting position for the AMR100 Reader.
2. Install an electrical box or drill mounting holes for #6 fasteners. Starter holes for mounting are indicated on Figure 2.
3. The Reader should be mounted at least 6" away from any metallic surface 12"x12" or larger. Incidental metal such as aluminum studs and conduit can be compen­sated.
.156 X .04 DEEP
12 PLACES
4.00
2.625
1.64
0.00
1.64
2.625
4.00
Important Product Specifications
Environmental Characteristics
Operating Temperature Range -0oC to 70oC (32oF to 150oF) Storage Temperature Range -40oC to 85oC (-40oF to 185oF)
Power Requirements
Operating Voltage Range 12.0VDC ± 1.2VDC Peak Current 12VDC 1.5A Average Current 1.0A Excitation Frequency 125KHz ± 1 KHz
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A 1 of 6
P
1
9
S
W
5
P
1
8
1
T
B
4
T
B
4
-
1
D
0
T
B
4
-
2
D
1
T
B
4
-
3
D
2
T
B
4
-
4
D
3
T
B
4
-
5
D
4
T
B
4
-
6
D
5
T
B
4
-
7
D
6
T
B
4
-
8
D
7
T
B
4
-
9
+
V
T
B
2
T
B
2
-
1
T
D
T
B
2
-
2
R
D
T
B
2
-
3
S
I
G
N
A
L
R
T
N
T
B
2
-
4
4
8
5
+
T
B
2
-
5
4
8
5
-
T
B
2
-
6
S
I
G
N
A
L
R
T
N
T
B
2
-
7
R
E
L
A
Y
1
N
/
C
T
B
2
-
8
R
E
L
A
Y
2
N
/
O
T
B
2
-
9
R
E
L
A
Y
1
C
O
M
M
T
B
2
-
1
0
R
E
L
A
Y
2
N
/
C
T
B
2
-
1
1
R
E
L
A
Y
2
N
/
O
T
B
2
-
1
2
R
E
L
A
Y
2
C
O
M
M
T
B
3
T
B
3
-
1
R
T
N
1
T
B
3
-
2
+
5
V
T
B
3
-
3
I
N
T
T
B
3
-
4
R
S
T
B
3
-
5
R
/
W
T
B
3
-
6
E
N
T
B
3
-
7
G
R
E
E
N
O
U
T
T
B
3
-
8
R
E
D
O
U
T
T
B
3
-
9
B
E
E
P
O
U
T
T
B
3
-
1
0
R
T
N
2
T
B
1
T
B
1
-
1
D
A
T
A
0
T
B
1
-
2
D
A
T
A
1
T
B
1
-
3
C
A
R
D
P
R
E
S
E
N
T
T
B
1
-
4
D
A
T
A
R
T
N
T
B
1
-
5
G
R
E
E
N
I
N
T
B
1
-
6
R
E
D
I
N
T
B
1
-
7
B
E
E
P
I
N
T
B
1
-
8
H
O
L
D
T
B
1
-
9
T
A
M
P
E
R
T
B
1
-
1
0
C
O
M
M
O
N
T
B
5
T
B
5
-
1
+
D
C
T
B
5
-
2
S
H
I
E
L
D
T
B
5
-
3
G
R
O
U
N
D
T
B
4
-
1
0
R
T
N
3
P
7
P
1
0
P
1
1
P
1
5
P
1
3
P
2
0
Cable Preparation
1. Route the cable from the AMR100 Reader and/or power supply to the Host.
2. Prepare the cable by cutting the jacket back 2" and strip the wires 1/4". Tinning the wires is not required.
3. Install the cable strain relief nut #1 on the rear of the AMR100 Reader as indicated in Figure 2 . (Strain relief nut #2 is for use with the LCD display unit that is purchased separately. If no LCD unit is being used and a water tight seal is necessary, place a cable segment into the strain relief nut #2 and tighten it)
4. Connect the Reader to the Host according to the terminal description in Figure 4. Do not leave extra loops of wire inside the Reader housing.
5. Tighten the strain relief nut to secure the cable.
6. Connect the drain line of the shield to TB5-2. (See Figure 3 ) If it is bare, sleeve it to avoid short circuits to the other wires.
7. The opposite end of the drain line should be connected to the negative terminal and the frame connections of the power supply.
8. Connect the power supply ground to TB5-3. (See Figure 3 )
Figure 3
TB3
1
1
TB4
1
1
TB1
TB2
Figure 2
8.00
5.25
3.28
A
2
12 PLCS, .156 STARTER HOLES FOR WALL MOUNT
1
TB3
TB4
1
SW1R5SW2 SW3 SW4
1 1
1 1
1
1
1
P12 P14
TB1
11
TB2
1
1 1
111
SW6
P8P5
1
1
P24
1
COVER
BASE
2
CABLE STRAIN RELIEF NUT
TB5
E5
1
P17
11
1
3
P9P6
P2
1
P41
P3
11
P16
P11
1
E4
SCREW
O-RING
1
A
8.00
Figure 4
TB5
1
This label is located on the inside base of the AMR100 Reader. It shows all the terminal connections for interfacing the AMR100 Property Pass Reader with the Host. TB3 and TB4 are for use with the LCD add-on unit.
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690 Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A 2 of 6
Loading...
+ 4 hidden pages