HID V2000 Installation Guide

NOTES, UNLESS OTHERWISE SPECIFIED:
1. THIS VERTX INSTALLATION WIRING DIAGRAM IS INTENDED AS AN EXAMPLE ONLY, AND SHOULD NOT BE INTERPRETED AS AN HID CORPORATION RECOMMENDATION.
2. THE DEFAULT SETTINGS FOR ALL VERTX INPUT DEVICES ARE NORMALLY OPEN (N/O), EXCEPT DOOR MONITOR INPUT WHICH IS NORMALLY CLOSED (N/C).
CAUTION: Some magnetic locks exhibit both high inrush current when activated and a high instantaneous break voltage when de-energized due to magnetic field collapse. It is recommended you use of a snubber circuit across the controlling relay terminals to protect the controlling relay contacts. Go to support.hidglobal.com, see Solution 891 - How do I wire a High In-Rush Current locking device to VertX/Edge/Edge Solo?.
HID
READER
- +
STANDARD MAG LOCK
CRASH
BAR
DOOR MONITOR
SWITCH N/C
MAG LOCK
SWITCH
REX SWITCH
IN CRASH BAR
DOOR #1
- +
12 OR 24
VDC POWER
SUPPLY
- +
­+ +
-
HORN OR
V2000 - DOOR/READER INTERFACE
CARD IN / FREE OUT
(MOST COMMON OPTION)
TO 12-24 VDC POWER SUPPLY
+ -
+ ­ AC Fail
(Input 6)
VertX EVO
RESET
J1
TCP/IP Ethernet
P7
- +
BAT
+12-24
Fail
VDC IN
(Input 7)
READER #2
COMM
Green - Comm OK Red - Comm Fail
P4
P5
P6
+ -
STROBE
RED
BLACK
GREEN
WHITE
ORANGE
BROWN
YELLOW
BLUE
SHIELD
- +
12 OR 24
VDC POWER
SUPPLY
READER PWR GROUND DATA0/DATA DATA1/CLOCK DATA RETURN GREEN LED RED LED BEEPER HOLD/CD PRESS SHIELD
+(IN1)
DOOR MONITOR
-(IN1) +(IN2)
REX
-(IN2)
NO
STRIKE RELAY
C
(OUT 1)
NC NO
AUX RELAY
C
(OUT 2)
NC
READER #1
P1
P2
P3
P10 Batt
Off On
+ ­Tamper
(Input 5)
V2000
POWER
LAN / WAN / INTERNET
READER PWR
GROUND
DATA0/DATA
DATA1/CLOCK
DATA RETURN
GREEN LED
RED LED
BEEPER
HOLD/CD PRES
SHIELD
DOOR
(IN3)+
MONITOR
(IN3)­(IN4)+
REX
(IN4)-
STRIKE RELAY
(OUT 3)
AUX RELAY (OUT 4)
NO NC
NO NC
V2000 - DOOR/READER INTERFACE
CARD IN / CARD OUT
(LESS COMMON OPTION)
TO 12-24 VDC POWER SUPPLY
+ -
+ -
+ -
RED BLACK GREEN WHITE
ORANGE
BROWN YELLOW BLUE SHIELD
C
PIR OR
+
REX
-
DOOR MONITOR
SWITCH N/C
-
ELECTRIC DOOR
STRIKE (LOCK)
+
HID
READER
+ -
C
DOOR #2
HID
READER
- +
STANDARD MAG LOCK
CRASH
BAR
- +
DOOR MONITOR
SWITCH N/C
ELEC LOCK
SWITCH
REX SWITCH
IN CRASH BAR
DOOR
RED
BLACK GREEN WHITE
ORANGE BROWN YELLOW BLUE SHIELD
­+ +
-
READER PWR GROUND DATA0/DATA DATA1/CLOCK DATA RETURN GREEN LED RED LED BEEPER HOLD/CD PRESS SHIELD
DOOR
+(IN1)
MONITOR
-(IN1) +(IN2)
REX
-(IN2)
NO
STRIKE RELAY
C
(OUT 1)
NC NO
AUX RELAY
C
(OUT 2)
NC
READER #1
P1
POWER
P2
P3
P10
Batt
Off On
Tamper
(Input 5)
V2000
LAN / WAN /
+ -
12 OR 24
VDC POWER
SUPPLY
- +
HORN OR
STROBE
+ -
12 OR 24
VDC POWER
SUPPLY
- +
12 OR 24
VDC POWER
SUPPLY
+ -
HORN OR
STROBE
- +
12 OR 24
VDC POWER
SUPPLY
INTERNET
AC Fail
(Input 6)
P7
VertX EVO
RESET
J1
TCP/IP Ethernet
- +
BAT
12-24
Fail
VDC IN
(Input 7)
READER #2
COMM
Green - Comm OK Red - Comm Fail
DATA RETURN
P4
HOLD/CD PRES
DOOR MONITOR
P5
STRIKE RELAY
(OUT 3)
P6
AUX RELAY (OUT 4)
READER PWR
GROUND
DATA0/DATA
DATA1/CLOCK
GREEN LED
RED LED
BEEPER
SHIELD
(IN3)+ (IN3)­(IN4)+
REX
(IN4)-
NO NC
NO NC
RED BLACK GREEN WHITE
ORANGE BROWN YELLOW BLUE SHIELD
HID
READER
C
C
REVISION HISTORY
REV ECO # DESCRIPTION
A.1 P/N INCORRECT
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION. IT MAY NOT BE DISCLOSED TO OTHERS OR USED FOR MANUFACTURING PURPOSES WITHOUT PERMISSION FROM HID CORPORATION.
CAGENOQTY
FIND
NO
EXCEPT AS NOTED
DIMENSIONS ARE IN INCHES
PER ANSI Y14.5M
.XX
.XXX
.01
+/-
MATERIAL
+/-
.005
REQD
ANGLES
1
+/-
FINISH
PART OR
IDENTIFYING NO
DO NOT SCALE DRAWING
APPROVALS
DWN
LDixon
DATE
DSGN CHK
APVD
APVD
100311
NOMENCLATURE OR
DESCRIPTION
IRVINE, CALIFORNIA
DWG TITLE
V2000 INSTALL WIRING
DIAGRAM EXAMPLE
SIZE CAGE CODE
B
N/A
SCALE:
DWG NO
72000-902
SHEET: 1 of
REV
A.1
1
Loading...