CAGE CODE DWG NUMBER
REV
B
Install Manual – 6055-910 Rev B 6055B HID MIFARE
Reader
_________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949)598-1600 (800)237-7769 FAX (949)598-1690 Internet - www.hidcorp.com - HID Mifare Reader Installation Manual 6055-910 Rev B Page 1 of 5
1 Parts List
PARTS LIST (Included) Quantity
- HID MIFARE Reader with snap-on cover and 18in.
- #6-32 x 1” self-tapping panhead screw
- Installation manual 1
PARTS LIST (Not-Included) Quantity
- Wire splice 9
- DC Power supply 12 VDC 1
1
2
2 Mounting Instructions
Determine an appropriate mounting location. The reader may be mounted to any surface, including metal.
Drill two (2) 3/32-inch (2.5mm) holes approximately 1 inch deep for mounting the reader.
Drill a 5/8-inch (16mm) hole for the cable.
A single-gang (2S) electrical junction box may
also be used; reader fits US hole pattern, and the 6-32 screws work with the J-box.
Remove the snap-on cover from the reader and secure the reader to the mounting surface.
Route the cable from the reader and/or power supply to the host. A linear type power supply is recommended. Check all electrical codes for proper cable installation.
For the cable connection to the panel - use Alpha #1299C or equivalent.
Test the operation of the reader (Section 4). After completion of the test, replace the snap-on cover.
See Figure 1 for product and mounting dimensions.
For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
The Reader is intended to be powered from a limited power source output of a previously certified power supply.
3 Connecting the Reader
Connect the reader to the host according to the wiring table below and the host installation guide.
Signal Color DB9F DB25F
9-14 VDC Red - ­GND Black Pin 5 Pin 7 D0 Green - ­D1 White - ­GRN LED Orange - ­RED LED Brown - ­Beeper HOLD Not Used RX DTR TX SHLD GND
Yellow Blue Violet Pink Gray Tan Drain
­Pin 1
­Pin 2 Pin 4 Pin 3
-
­Pin 8
­Pin 3 Pin 20 Pin 2
-
4 Testing and Operation
When power is applied to the reader the beeper will beep and flash the LED green three times.
Present an ID card to the reader. The LED will momentarily turn green while the beeper beeps once, indicating that the card was read successfully.
Please note that typical read range for MIFARE cards is .75 to 1.5” (20 – 37 mm).
Important Product Specifications
Power supply Absolute Maximum Voltage Maximum Current at 12V Operating Voltage Range
Maximum cable distance To host
Operating temperature range
FCC Compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Linear type 16 VDC 50mA
9.0 – 14.0 VDC
50 ft RS-232 500 ft Wiegand
-30 to 65°C
5 Card Compatibility
_________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949)598-1600 (800)237-7769 FAX (949)598-1690 Internet - www.hidcorp.com - HID Mifare Reader Installation Manual 6055-910 Rev B Page 2 of 5
In the default configuration, the HID MIFARE Reader reads HID-encoded OEM Card Data (Wiegand data) from these cards:
HID MIFARE Card, Model 1430
HID MIFARE/Prox, Model 1431 (dual
technology)
Any Philips compatible MIFARE Standard contactless smart card.
The HID MIFARE reader will not read 125 kHz HID Proximity cards.
The reader will only output HID-encoded OEM Wiegand data from cards encoded with matching proprietary HID keys. Cards can either be encoded at the factory, or by using an available HID MIFARE Field Programmer.
The reader will read the MIFARE Card Serial Number only from MIFARE Lite and MIFARE Pro cards. These cards are not available with Factory-encoded HID Card Data.
6 Reader Operation
There are two basic modes of reader operation: Security Mode (the default mode) and Transaction Mode.
Security Mode
Security Mode is for use in Access Control and parking applications. In security mode, the reader looks for two types of data on the card:
HID Factory encoded OEM format card data
Mifare Card Serial Number (CSN)
The reader may be configured in one of the
following Card Read Modes:
HID Card Data Only (default mode)
Mifare CSN Only
HID Card Data first, then look for CSN
In HID-Only Mode, when a card is presented, the
HID MIFARE Reader will look for HID-Encoded OEM card data in Sector 1 as well as the MIFARE Application Directory. Data is output in standard Wiegand format, exactly as it is encoded on the Mifare card, and it is also output on the serial port. The reader can also be field­configured to look for HID-encoded OEM card data in a specific sector other than Sector 1.
In CSN Only mode, the reader reads the 32-bit MIFARE random card serial number (CSN or UID) from any MIFARE card, including MIFARE Lite, MIFARE Standard and MIFARE Pro, outputting that data in a Wiegand format. MIFARE CSN Data is output via the Wiegand port per the reader’s configuration to one of the following CSN Output Modes:
32-bit Philips standard, MSB first (default)
32-bit Reverse Order (6055A compatible)
26-bit format (32-bit, truncated to 16 LSB, 8-
bit FC defaulted to 1, B/E parity) - FC may be user-configured)
34-bit, Philips Standard + B/E parity
40-bit format - 32-bit CSN + 8 bit checksum
In HID+CSN mode, the reader first checks all
possible locations for HID OEM data, and if no HID data is found, it outputs the CSN.
Card Read Mode and CSN Output Mode can be ordered pre-configured at the factory, or may be field-configured with Command Cards.
Consult HID Technical Support for information on obtaining Command cards or for additional details on configuration options.
Transaction Mode
The reader can also communicate via the serial port for non-access control applications, including read-write capability. When in transaction mode, the reader asserts the DTR line to alert the Host that a card ID is outputting, and it will continue to output repeatedly until acknowledged by the host controller. Configuration to Transaction Mode is accomplished by a command from the Host via the serial port. No command card is required, and no special factory configuration is required.
A Software Development Kit is available – please contact your dealer for details.
7 Additional Requirements for
European Installation
To comply with EU RF emission standards, it is necessary to install two components as shown in Figures 2 and 3: one in the line between the power supply and the unit, and another on the line between the AC mains and the power supply.
Parts Required (not supplied)
Fairrite Toroid - P/N #2643802702 * Fairrite Clamp-on Ferrite - P/N #0443164151 *
_________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949)598-1600 (800)237-7769 FAX (949)598-1690 Internet - www.hidcorp.com - HID Mifare Reader Installation Manual 6055-910 Rev B Page 3 of 5
0
24 AWG Enamel Wire White/Red 22AWG lead wire, 12” White/Black 22AWG lead wire, 12”
*Fair-Rite Prod.Corp. www.fair-rite.com
Instructions:
Form a coil by wrapping 39 turns of a pair of enamel wires around the toroid (see Figure 3).
Attach Red and Black wires to one end of the coil.
Attach White/Red wire to the opposite end of the
coil wire connected to the Red wire.
Attach the White/Black wire to the opposite end of
Connect the black lead to the – side of the power
supply output.
Connect the White/Red lead to the Red wire from the reader.
Connect the White/Black lead to the Black wire from the reader.
Install the ferrite clamp on the cable, which supplies AC line voltage to the power supply. When installing the clamp-on ferrite part, three loops should be formed in the power cable between the 220 VAC source and the power supply so that the ferrite clamp is clamped over 4 wires.
the coil wire connected to the Black wire.
Connect the red lead to the + side of the power supply output.
3.000
.68
4.02
4.700
7
.125
3.280
.15 X .16 SLOT
Figure 1 Front, Side and Back Views
_________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949)598-1600 (800)237-7769 FAX (949)598-1690 Internet - www.hidcorp.com - HID Mifare Reader Installation Manual 6055-910 Rev B Page 4 of 5
Three Loops
Three Loops
Red/White Wire
Red/White Wire
Toroid
Black/White Wire
Black/White Wire
Toroid
Red Wire
Red Wire
+ +
-
-
Black Wire
Black Wire
Figure 2. Installation of reader with ferrite clamp and toroid
Red
Red
Black
Black
Red/White
Red/White
Black/White
Black/White
Figure 3. Details of toroid required for CE compliance.
_________________________________________________________________________________________________ HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949)598-1600 (800)237-7769 FAX (949)598-1690 Internet - www.hidcorp.com - HID Mifare Reader Installation Manual 6055-910 Rev B Page 5 of 5