3110-2305 Model 230 Prox/Magstripe
Reader, Black
3110-2405 Model 240 Prox/Magstripe
Reader, with keypad, Black
Installation Guide
© 2007 HID Global Corporation. All rights reserved.
P/N 2280-4587, Rev C.3 June 27, 2007
9292 Jeronimo Road
Irvine, CA 92618-1905
Voice: (800) 237-7769
Fax: (949) 598-1619
email:
tech@HIDcorp.com
internet: www.HIDcorp.com
Parts List
Card Reader kit consists of:
1-Reader assemly
1-Installation Kit 2270-0580
• Two 6-32 x 3/5" Phillips pan head screws
• Cord, Buna 70, .103 diameter
• Cover removal tool
• Six Wire Cable Connector assembly
1-Instructions 2280-4587
General
The Model 230/240 Wall Mount Combination Proximity &
Magnetic Stripe Card Readers read the following format cards:
• Magnetic Stripe: ABA/ANSI/ISO and EMPI
• Proximity: HID 26-36 bit, EMPI and Proxi 10
The readers are normally wall mounted and designed for indoor
or outdoor use.
Proximity cards are placed in front of the reader and normally
read at a distance of six inches (15.2 cm) at +5 VDC and seven
inches (17.7 cm) at 12.0 VDC. Mounting the readers on metal
will typically reduce the distance. The data is transmitted to any
host controller that can supply +5 to +24 VDC operating voltage
to the reader, and that can accept the standard Wiegand 26-bit
or 34-bit format.
3. For outdoor applications, use a suitable weather-proof
back box, or handy box, and install the weather seal
(provided) on the back of the readers' base by pushing it
securely and evenly into the "U" shaped recess. See
Figure 2.
Figure 1
Pre-Installation
1. The host controller must supply +5 to +24 VDC operating
voltage to the reader. The voltage drop as measured
across the reader must be within 5 to 24.0 VDC.
2. The maximum recommended reader distance from the
host is:
200 feet with #22 AWG 5 or 6-wire cable
500 feet with #18 AWG 5 or 6-wire cable
Unshielded wire is acceptable. Some host controllers
may require tighter standards.
Mounting
1. The reader is designed to be mounted with the slot
facing the floor. The user inserts the card upward into the
card insertion slot.
2. The reader can be mounted on a standard single-gang
handy box, (the preferred method) or on any firm flat
surface. The mounting screws should be firmly tightened,
but not excessively. Note that the read head assembly
screws are purposely loose to allow the head to "float";
no adjustments are necessary. See Figure 1.
Grasp the lower edge of the reader cover. While applying
gentle pressure pull the cover away from the base.
4. Recommended reader mounting height from the floor is
"shoulder height" or about 60 inches. A lower height
causes significant user inconvenience. Reader height
may be lowered to accommodate ADA requirements.
Figure 2
Installation Instructions
WARNING: To prevent damage to equipment,
make all connections with power off.
1. If the reader is to be mounted on a mullion or firm flat
surface, pull an appropriate length and gauge of cable
between the host and mullion.
2. If the reader is to be mounted on a flat surface rather
than a handy box, use the reader base both as a
template to establish drill locations for suitable molly
fasteners, etc. (not provided), and as a guide to remove
sufficient material for wire clearance. Then pull the
appropriate wire between the host and reader location.
3. Connect the wires of the pigtail assembly to the cable
end at the reader location. Connections can be crimped
or made with twist on wire nuts.
FUNCTION WIRE COLOR
+5 to 24 VDC RED
Green LED BROWN
Data "1" /Data Output WHITE
Data "0" /Clock Output GREEN
COMMON BLACK
Buzzer YELLOW
Format Selection Switch (16 position rotary)
1 ABA mag stripe to All Bits Wiegand & HID prox*
2 ABA mag stripe to Wiegand 26 bit & HID prox*
3 ABA mag stripe to Wiegand 34 bit & HID prox
4 EMPI mag stripe & EMPI prox to Wiegand 26 bit
5 EMPI mag stripe & EMPI prox to Wiegand 34 bit
6 EMPI mag stripe to Wiegand 26 bit & HID prox*
7 EMPI mag stripe to Wiegand 34 bit & HID prox*
Following ABA only ANSI 10 or 12 (5/5 or 6/6)
8 ABA mag stripe & Proxi 10 prox to Wiegand 26 bit
9 ABA mag stripe & Proxi 10 prox to Wiegand 34 bit
A ABA mag stripe to Wiegand 26 bit & HID prox
B ABA mag stripe to Wiegand 34 bit & HID prox
* HID Prox data output is determined by card encoding, up to 36
bits max. This reader will not read HID 37 bit or formats which
require additional processing by the reader.
4. Connect the other end of the cable to the host controller
being sure to follow the appropriate color code and wire
lead functions.
5. Verify that the cards to be read are encoded with the
selected data format.
6. Observe the reader LED; it should flash green four times
as a self-test when first powered on. If this is not the
case, or it continues with short double flashes, a problem
exists, refer to the Diagnostic Tests section.
Keypad Data
The model 240 keypad sends data keystroke-by-keystroke to
the host controller in an 8-bit (per keystroke) data format.
Diagnostic Tests
The Model 230 and 240 Proximity Card Readers are factory
calibrated and are not field serviceable.
1. A card with the expected card format will cause the
reader LED to "wink" dark and the buzzer to sound for
0.1 second while outputting data to the host.
2. Direct substitution with a known good reader is the best
way to isolate the problem.
3. If the reader is exchanged and the problem still exists,
measure the voltage drop at the reader between the RED
(Positive) and the BLACK (Common) wire with the reader
connected to the host. It should measure between 5 and
24.0 VDC. Low voltage is a common source of problems.
4. Verify that the card used to test is a known good card,
and is authorized in host memory. Verify the reader
options are set correctly for that particular host, and the
proper "Comparison Number" or site code has been
recorded in host memory.
5. Verify the wiring, continuity, and connections between
reader and host. If possible, switch the reader input
wiring at the host to another known good input terminal
group.
6. If the problem still cannot be resolved, contact your HID
reseller for assistance.
Specifications
INPUT:
Magnetic Stripe: ABA/ANSI/ISO & EMPI Proximity:
HID 26 – 36 bit or EMPI or PROXI 10.
37 bit or formats which require additional processing by the
reader.)
READING DISTANCE:
7” (17.7 cm) typical at 12 VDC (6” or 15.2 cm if
mounted on metal)
6” (15.2 cm) typical at 5 VDC (5” or 12.7 cm if mounted
on metal)
DATA OUTPUT:
Proximity Data: Output based on card type. HID up to
36 bit.
Magnetic Stripe Data: Wiegand 26, Wiegand 34 or All
its Wiegand (up to 64 bits)
LED CONTROL:
Red/Green control with brown wire control line (ground
wire)
WIRE LENGTH:
200 feet (61m) with #22 AWG wire
500 feet (153m) with #18 AWG wire
TEMPERATURE RANGE:
-35 to +66 degrees Celsius (-31 to 150 degrees
Fahrenheit).
POWER:
5 VDC to 24.0 VDC input
120 mA nominal at +5.0 VDC
170 mA nominal at +12.0 VDC
READ SPEED:
80 milliseconds
DIMENSIONS:
4.70 in H x 3.00 in W x 1.54 in D
11.9 cm H x 7.6 cm W x 3.9 cm D
BUZZER:
Activates momentarily upon card acceptance and
Keystroke activation or grounding of yellow wire.
(Will not read HID
Regulatory
FCC
This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
UL
This Proximity Reader is intended to be powered from a limited
power source output of a previously certified power supply.
This Reader is intended to be used with UL 294 Listed Control
Equipment.
CE Marking
HID Global hereby declares that this proximity reader is in
compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC.