Thank you very much for your preference for products. Our objective
is to ensure that you enjoy this product, manufactured environmentallyfriendly with a total sense of quality in a precise working environment at
our modern facilities, most efciently.
We recommend you to read the instruction manual carefully and keep
it handy before you use this chimney hood so that it maintains its quality
just like the rst day you bought it and serves you most efciently.
Note: This instruction manual has been prepared for a variety of models.
Some of the features specied in the Manual may not exist in your device.
These features are marked with *.
Our devices are designed for domestic use. They are not for professional
use.
“PLEASE READ THE INSTRUCTIONS BEFORE YOU INSTALL OR USE THIS
DEVICE.”
This product has been manufactured in an environmentally-friendly and
modern plants without harming the nature.
“Conforms with the AEEE Regulations.”
2
Contents
1. Safety Instructions
2. Introduction And Technical Drawing
Of The Chimney Hood 7
3. Installation Of Chimney Hood 8
3.1. Location Of The Chimney Hood 8
3.2. Installation Of Mounting Bracket
To The Chimney Hood 8
3.3. Installation Of Wall Mounting Bracket 8
3.4. Installation Of Inner Duct Mounting Bracket 9
4. Mounting The Chimney Hood On The Wall 9
4.1. Leveling The Chimney Hood 9
4.2. Mounting The Aluminum Pipe 9
5. Functions Of The Chimney Hood10
5.1. Control Panel10
5.2. Symbols Functions10
5.3. Four Button Touch Control11
5.4. Screenless Touch Control12
6. Operating The Chimney Hood12
6.1. In Ducted Use13
6.2. Round Charcoal Filter13
6.3. Use Of Charcoal Filter13
6.4. Installation Of Charcoal Filter13
6.5. Use Of Aluminum Cartridge Filter13
7. Replacing The Bulb14
8. Maintenance Of The Chimney Hood14
9. If Chimney Hood Does Not Work15
10. Environmentally-Friendly Disposal16
11. Package Information16
4
3
GB
SAFETY INSTRUCTIONS
1. The installation of the product should be carried
out by authorized persons. Installation performed by
unauthorized persons may result in poor performance,
damage to the product or accidents. The product will
not be covered by the warranty.
2. When an electric cooker hood is used simultaneously
with the devices which burn gas or other fuels, the
room should be ventilated adequately (not applicable
for devices that discharge air back into the room).
3. An electric cooker hood should not be connected
to a ue or air duct used to drain smoke from devices
which burn gas or other fuels (oven, water heater,
thermosyphon, etc.) (not applicable for devices that
discharge air back into the room).
4. Comply with the instructions regarding discharge
of outlet air, stipulated by the relevant authorities (not
applicable for devices that discharge air back into the
room).
5. When the cooker hood is placed on a gas burning
device, the distance between the hob and the hood
should be at least 65 cm. If a larger distance is specied
in the installation instructions of the gas burning hobs,
this value should be taken into account.
6. Packaging materials may be dangerous for children.
Do not allow children to play with packaging materials.
Keep packaging materials out of reach of children.
4
7. This device is not designed to be used by children,
people with physical, sensory or mental incapabilities,
or with lack of experience or technical knowledge. Do
not allow the persons and children under custody to
use the product, play with the product, to perform
maintenance and cleaning on the product.
8. Kitchen hoods are designed for domestic use. They
should not be used for other purposes. Otherwise, it
may cause various accidents and the device will be out
of warranty.
9. The electrical connection of the product must be
done to a grounded outlet.
10. Before the installation, maintenance and cleaning
of the product, de-energize the device. (By unplugging
the device or by switching off the fuse)
11. For your safety, use ”Max 6 A” fuses in the hood
installation.
12. Do not operate the hood without using cookwares.
High heat may cause some parts of your product to
deform and cause re.
13. Do not leave boiling oil on the stove. Pots that
contain boiling oil may catch re by itself.
Clean the oil trap aluminium lters regularly. Filters
14.
pose risk of re due to accumulated grease deposits on
them.
5
GB
15. Do not operate your product without lter, and do
not remove the lters when the product is in operation.
Do not use non-re-resistant ltering materials instead
of the lter.
16. Flammable foods must not be cooked under the
appliance.
17. Risk of re may occur if cleaning is not carried out
periodically and according to instructions.
18. In case of any re, de-energize devices. Cover the
ames with a damp cloth or towel. Never use water to
put out the ames.
19. The mains cable should not be passed near stoves,
or devices or equipment which may come into contact
with heat or which may deform the cable. This may
cause re.
20. Do not touch your product’s lamps when they work
for a long time. Since they would be hot, they could
burn your hand.
21. CAUTION: Accessible sections may be hot when
used with cooking appliances.
22.WARNING: Failure to install screws or xing
installations in accordance with these instructions may
result in electrical hazards.
6
2. INTRODUCTION AND TECHNICAL DRAWING OF THE CHIMNEY HOOD
D
D
A
20
C
4
5
E
PRODUCT
MDD*-056... MDD*-059... MDD*-216... MDD*-156...
MODELS
A
265265265310200200265265265265
B
210210216290170170210210216210
C
350350350350300300350350350350
Min
782782772635662662840783850781
Max
1112111210029659429421170111311801115
E
460460450450410395385430440445
F
595895595595595595595595595595
G
470470440465362362505450505448
Ø150
B
1
1. Inner ue plate
2. Outer ue plate
3. Control keys
2
4. Plate body
5. Cover glass
3
G
F
MDD*-146...
MDD*-256...
MDD*-266...
MDD*-346...
MDD*-236...
MDD*-246...
MDDX-286... MDDX-276... MDDX-306...
MDDX-296...
MDDX-316...
MDDX-326...
MDDX-366...
All dimensions are in millimeter.
7
GB
3. INSTALLATION OF CHIMNEY HOOD
3.1. Location Of The Chimney Hood
Min. 650 mm.
0
0
10
50
20
MAX
250
80
30
90
80
40
220
50
70
130
180
60
3.2. Installation Of Mounting Bracket To The Chimney Hood
Fix the 2 (two) Mounting brackets among the installation accessories to
the chimney hood with one 1 screw nut as shown in Figure 1. Make sure
mounting brackets are inserted in motor box.
3.3. Installation Of Wall Mounting Bracket
Drywall (8mm) anchors are nailed into the holes drilled according
to installation template (A,B,C,D). They are xed into the wall with 2
brackets as shown in Figure 2.
AB
Figure 1
C
D
Installation template
8
Figure 2
3.4. Installation Of Inner Duct Mounting Bracket
2 xing holes are drilled on the wall with Ø 6 mm electric drill at a
suitable height and place to x the inner duct hanger plate onto the wall.
6mm drywall anchors are nailed into those holes and inner duct mounting
brackrets are pinned down.At the last step of chimney hood installation,
the inner duct is screwed on the inner duct mounting brackets.
4. MOUNTING THE CHIMNEY HOOD ON THE WALL
Lift the chimney hood body and x the hanger plates onto the wall
anchors as shown in Figure 3.
Figure 4Figure 3
4.1. Leveling The Chimney Hood
If the chimney hood is inclined on one side, the chimney hood
can be leveled with the adjustment screws as shown in Figure 4.
Once the balancing is complete, the screws shown in Figure 5 must be
xed tightly. After this, x the body with one screw through the hole on
the body.
4.2. Mounting The Aluminum Pipe
Place the aluminum pipe on the plastic duct. Place the other end of the
pipe into the air outlet in the kitchen. (Figure 6)
Figure 5Figure 6
9
GB
Twists and bends on the aluminum pipe may cause minimizing the air suction
so avoid unnecessary bends and twists as much as possible. (Figure 7-8)
Place the inner duct and outer duct carefully on the product. Fix the inner
duct to inner duct connection plate with 2 screws. (Figure 9)
Figure 7Figure 8Figure 9
5. FUNCTIONS OF THE CHIMNEY HOOD
5.1. Control Panel
Digital Control: Touch the symbols on the keys. (On/Off function and timer
are on the same key; if pressed for 1 sec on-off function will operate.If
pressed for 3 sec. 15 minutes timer will operate.
Touch Control: Touch the symbols on the glass surface. If Press a symbol
longer (more 3 sec) may operate various functions.
5.2. Symbols Functions
Switches on and off the motor.
(Except for the lighting)
Decreases the speed when the motor
is running.
Display
Increases the speed when the motor
is running.
If pressed this symbol, the motor
turns itself off 15 minutes later.
Only switches on and off the lighting
system.
Note: When the product operates for a certain time, the aluminum lters
get dirty and the digital display shows “C” Clean sign. This means the
lters should be cleaned. Press the speed reduction key for 5 secs in
order to delete “C” sign from the display.
CAUTİON: When the timer key is pressed for 3 secs digital display starts
to change.Air-circulation system of the chimney hood becomes active.
The chimney hood runs for 10 minutes in the lowest speed. Then the
system automatically shuts down.
10
5.3 Four Button Touch Control*
ON/OFF ButtonPlus ButtonMinus Button
Timer
Lamp
• ON&OFF: Starts the motor.
• Speed +: Increase the speed of the motor. Max: 3 speed.
• Speed -: Decrease the speed of the motor. Max: 1 speed.
• Lamp: Turns the lamp on. When the lamp is on, the dot segment is
viewed on the screen.
• Timer: If the lamp button is pressed for 3 seconds, the device starts
ashing in respective speed. After 15 minutes the device is turned off.
• Air Cleaning: When the air cleaning button is pressed on the
Remote Control, the function is initiated. The motor is operated for 10
minutes in 1 speed, then switches to standby for 50 minutes. While
this function is active, the screen segments start rotating. Then the
system shuts down automatically. The rotation is only for 24 hours.
• Filter Warning: At the end of 100 hours of operation, the ‘C’ warning
is viewed on the screen. This warning can be deleted by pressing the
speed - button for 5 seconds, the ‘E’ is viewed on the screen, the
warning is deleted and the timer is reset. This warning is viewed for 2
seconds when on/off button is pressed. During rotation changes this
warning is not displayed.
• Automatic Shutdown: For safety purposes, the circuit board of the
motor is programmed to provide maximum of 5 hours lighting and
maximum 10 hours of operation. When the air cleaning function is in
effect, the motor shutdown feature is turned off.