HF scientific Chlorine Dioxide Pocket Photometer Field Portable User Manual

OWNERS MANUAL
Chlorine Dioxide Pocket Photometer
Field Portable
HF scientific 3170 Metro Parkway Ft. Myers, FL 33916 Phone: 239-337-2116 Fax: 239-332-7643
Email: HFinfo@Watts.com
www.hfscientific.com
Manual Part No. 24055 (1/09) Rev. 1.1

DECLARATION OF CONFORMITY

Application of Council Directive
Standard to which Conformity is Declared:
Product Safety - Tested and passed CE EN61010-1:1990 + A1:1992 (73/32 EEC)
Immunity and Emissions – Tested and passed EN61326-1:2006
Manufacturer’s Name: HF scientific, inc.
Manufacturer’s Address: 3170 Metro Parkway, Fort Myers, Florida 33916-7597
Type of Equipment: Field Portable
Model No: Chlorine Dioxide Pocket Photometer
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive and Standard
Place: Fort Myers, Florida USA (Signature)
Date: November 16, 2005 Rowan T. Connelly, General Manager
_______________________________
24055 (1/09) i Rev.1.1

Table of Contents

DECLARATION OF CONFORMITY..........................................Error! Bookmark not defined.
Specifications.................................................................................................................................. 1
1.0 Overview............................................................................................................................. 2
1.1 Unpacking and Inspection of the Instrument and Accessories....................................... 2
1.2 The Display..................................................................................................................... 3
1.3 The Instrument and Touch Pad....................................................................................... 3
2.0 Safety .................................................................................................................................. 4
3.0 Normal Operation ............................................................................................................... 5
3.1 Routine Measurement..................................................................................................... 5
4.0 Instrument Calibration........................................................................................................ 5
5.0 Troubleshooting.................................................................................................................. 7
5.1 System Warning Messages............................................................................................. 7
5.2 System Error Messages................................................................................................... 7
5.3 Technical and Customer Assistance ............................................................................... 8
6.0 Routine Maintenance.......................................................................................................... 9
6.1 Cuvette Cleaning and Care ............................................................................................. 9
6.2 Battery Replacement....................................................................................................... 9
7.0 Accessories and Replacement Parts List........................................................................... 10
8.0 Warranty ........................................................................................................................... 11
8.1 Waterproof Seal……………………………………………………………………………………………... 11
24055 (1/09) ii Rev. 1.1

Specifications

Measurement Range
Resolution
Regulatory Compliance US Standard Methods
Response Time Less than 5 seconds
Display 7 Segment Liquid Crystal Display
Operating Temperature Range
Sample Temperature Range 0°C – 50°C (32°F – 122°F) Relative Humidity 0-90% Non Condensing
Power Supply 4 – AAA Batteries (life is approximately 1000 readings using
Certification CE
Insulation Rating Pollution Degree 2
Approximate Dimensions Instrument: 7 cm x 16.5 cm x 4.8 cm (2 ¾” x 6 ½” x 1 7/8”)
0-6 mg/l (PPM) Trending 0-10 mg/l (PPM)
0.01 mg/l
EPA Approved
0°C – 50°C (32°F – 122°F)
standard alkaline batteries)
Instrument in Minilab Case
Enclosure Rating:
Shipping Weight: 1.22 kg (2.70 lbs)
Shipping Dimensions: 28 cm x 30.5 cm x 7.6 cm (11” x 12” x 3”)
Warranty 1 Year from date of shipment
NEMA 4X Designed to meet the specifications of IP67
24055 (1/09) Rev. 1.1