Hexin HXSP-2108W Quick Start Manual

Http://www.hexin-technology.com/
Quick Start Guide
Wi-Fi TO RS-232/422/485
CONVERTER
MODEL HXSP-2108W
. Check Package Content
HXSP-2108W unit 1Pcs
RS-232 DB9 Female Crossingconfiguration cable
1Pcs
Software CD 1Pcs
Ext power adapter 1Pcs
Printed version of this HXSP-2108W Quick Start Guide
1Pcs
.Hardware Installation
Connect RS-232DB9 Female Crossing configuration cable to HXSP-2108W unit on RS-232 side.
Connecting the Power Adapter to HXSP-2108W power jack. When the power is properly supplied.The Link and DIS. LED will light in red and yellow color until the system is ready, at which time the Link. LED will be put out and DIS PWR LED still light.
RS-232/422/485 Pinouts
RS-232 Pinout(DB9 Female )
PIN
RS-232
Input/Output
2
RXD
I
3
TXD
O
5
GND
-
7
RTS
O
8
CTS
I
RS-422/485 Pinout(SIX Terminal from Left)
PIN
RS-422
RS-485
1T+485+ 2T-485­3R+NC 4R-NC 5
VIN+
VIN+ 6
VIN-
VIN+
. LED indication
LINK ---- Indicate WLAN status DIS ---- Indicate WLAN status ACT ---- It will flash when transmit the data from WLAN to serial or from serial to WLAN. PWR ---- Indicate the Power supply Detail for LINK,DIS Led indicate
LINK
DIS
Status
OFF
OFF
WLAN Connecting
ON
OFF
WLAN Connected
OFFONWLAN Disconnect
ONONSetup Command
.Software Installation
Insert the software CD and search for such as F:/Tool/
pcommlite folder to run Settup.exe.Note: Be sure you have administrative rights &disable firewalls in windows XP
.Configure the HXSP-2108W
■Serial Console (38400, n, 8, 1)
Before configuring the HXSP-2108W via the serial console,
turn off the power and use a serial cable to connect the HXSP-2108W to your computer’s serial port. We suggest using PComm Terminal Emulator, which is available in CD driver to carry out the configuration procedure. Firstly install PComm Terminal Emulator on your computer.
Connect HXSP-2108W RS-232 serial port directly to your computer’s male RS-232 serial Port with RS-232 DB9 Female Cross Configuration cable
From the Windows desktop, click on Start # Programs # PComm Lite # Terminal Emulator.
When the PComm Terminal Emulator window opens, first click on the Port Manager menu item and select Open, or click on the Open icon.
The Property window opens automatically. From the Communication Parameter page,
select the appropriate COM port for the connection, COM1 in this example, and 38400 for
Baud Rate, 8 for Data Bits, None for Parity, and 1 for Stop Bits.
From the Property window.sTerminal page, select ANSI or VT100 for Terminal Type, and click on OK. If you select
Http://www.hexin-technology.com/
Dumb Terminal as the terminal type, some of the console
functions—especially the .Monitor. function—may not work properly.
Press the “ ←” backspace key (located in the upper right corner of the keyboard) continuously while powering on the HXSP-2108W
Sending a continuous “ ←” backspace string to HXSP-2108W triggers it to switch automatically from data mode to console mode.
Start by configuring the IP address and WLAN under MS-DOS Command Mode.section for instructions on how to configure the rest of the IP settings.
Choosing the Proper Operation Mode
6
6
.Factory Default WLAN &IP Address
Network Setting
IP :192.168.1.250 MASK :255.255.255.0 GW :192.168.1.254 DHCP :OFF
Wireless LAN Commands
CHAN :6 MODE :infrastructure SSID :wlandemo RATE :11 mbps WEP :OFF
Serial Port Commands
Baud Rate:38400 bps Serial Flow Control setting :OFF TCP Serial Port Number :1234
7
7
.Summary of Commands – Listed by Functional
Category
(These commands are explained in detail with more detailed functioning examples further in this document.)
Network Commands
IP xxx.xxx.xxx.xxx Where x is the IP of this device MASK xxx.xxx.xxx.xxx Where x is the Network Mask of this device GW xxx.xxx.xxx.xxx Where x is the Gateway of this device DHCP x Where x is the DHCP setting: 1=ON 0=OFF
Wireless LAN Commands
CHAN x Where x is the channel setting 1-14 MODE x Where x Network Mode x = a(ad hoc) b(infrastructure) p(Pseudo IBSS) SSID xxxxxxxxx Where x is the multi-character SSID network name RATE x Where x is the Tx rate, 1,2,5,11 mbps WEP x Where x is WEP key 0=OFF, 1=64bit, 2=128bit WK x yyyyyyyyyy Load WEP Encryption Key into WEP buffers 1, 2, 3 or 4 WKID x Where x is the Buffer of the WEP encryption key in use 1, 2, 3 or 4
AA x Where x is the authentication: A=Auto, S=Shared Key, O=Open
Serial Port Commands
BAUD x Where x is serial port baud rate, 0=115200, 1=57600, 2=38400, 3=9600 FCTL x Where x is Serial Flow Control setting, 1=ON, 0=OFF PORT xxxxx Where x= TCP Serial Port Number (Default value is “1234”)
Server/Client Settings
RMODE x Where x is CLIENT or SERVER setting for this device RIP xxx.xxx.xxx.xxx Where x is Server Target Remote IP when this device is in Client mode. RPORT xxxxx Where x is Server Target Remote PORT when this device Client mode.
Enter Command Mode
SetUpWLAN Gatekeeper Command Entry String
Exit and Save Settings Commands
EXIT Exits Command Mode but DOES NOT SAVE CHANGES SAVE SAVE Command (Saves only but does not Exit Configuration Mode.) SE SAVES and EXITS Command Mode simultaneously
Other Commands
PSMOD x Where x is the power saving mode: 1=ON 0=OFF RES Reset as if a Hardware reset was applied DEF Restores all settings to Factory Default MAC Read-Only command that display the unique MAC addressVER Read-Only command returns Firmware Version Number HELP Displays list of all available Commands along with abbreviated format LIST Displays alphabetic readout of all Settings