Hewlett Packard Enterprise Q2Q28A, Q8H39A Getting Started Guide

QuickSpecs
Nimble Storage Adaptive Flash Arrays

Overview

Page 1
Nimble Storage Adaptive Flash Arrays
Nimble Storage Adaptive Flash Arrays from Nimble Storage, a Hewlett Packard Enterprise company, are the industry’s only predictive hybrid flash platform. This is achieved by combining a flash access to data with
Nimble Storage CS1000 and CS1000H Adaptive Flash Arrays are the hybrid entry point to the Nimble Predictive Cloud platform, providing value and simplicity for mixed, mainstream workloads. They comb resiliency at an economical price point. The arrays allow you to start small and scale up to 294
Since they are backed by our Timeless Storage guarantee become a thing of the past.
Designed to radically simplify operations, Nimble Storage Adaptive Flash Arrays feature InfoSight prevent issues across the infrastructu collected the necessary information to solve the problem, removing the need for complex troubleshooting. As a result, traditi level 1 and 2 support staff is compl level 3 experts who answer calls in less than a minute on average.
NOTE:
Nimble
Nimble Storage CS1000 Adaptive Flash Array4
3 bays hold Dual Flash Carriers with Small Form Factor SSDs)
NOTE:
1
2
Refer to the whitepaper
3
Subject to Nimble Storage General Terms and Conditions available at
4
2 bays holding Dual Flash Carriers with SFF Solid State Drives.
arrays1 delivering radical simplicity with consistently good performance within a scalable, cloud-ready
-optimized architecture with InfoSight Predictive Analytics—giving you fast, reliable
proven, measured availability of greater than 99.9999%2.
ine a flash-optimized architecture, scalability and
3
, there is no need to pay for optional software, and forklift upgrades can
re stack. Even the most complex issues are rapidly resolved because InfoSight has already
etely automated by InfoSight. The Nimble Storage support organization is entirely comprised of
For more information about the entire Nimble Storage product portfolio, go to http://www.nimblestorage.com.
Storage products are not available in some markets.
TB raw capacity with the CS1000.
Predictive Analytics, predict and
onal
(Base array, 4U; 21 bays hold carriers with Large Form Factor HDDs,
Based on publicly available information as of May 2017. Based on actual customer data collected by the Nimble Storage support organization as of March 2017.
Redefining the Standard for System Availability for additional details (registration required).
Refer to https://www.nimblestorage.com/satisfaction-guarantee/ for details.
http://www.nimblestorage.com/docs.
Nimble Storage CS1000H Adaptive Flash Array (not shown) has 22 bays holding LFF Hard drives and
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Overview
Page 2
Flash Performance for Mixed, Mainstream Workloads
",
Cloud-ready. Flexibility to create a multicloud environment with Nimble Cloud Volumes.
InfoSight Predictive Analytics
process, and connecting you directly to support expertise. No more answering routine support questions, sending log files, or attempting to recreate issues.
Unparalleled Hybrid Efficiency
deliver up to 2-3X space savings without performance penalty8.
Absolute Resiliency
Error! Bookmark not defined.
tolerant design achieve over
snapshots and replication as well as integration with leading backup software solutions.
NOTE:
5
whitepaper
6
Labs Research Report
7
Efficiency comparisons based on a combination of technologies including and the use of 3D NAND flash.
8
enables the arrays to provide Always
Nimble Storage Adaptive Flash Array models
Speed and efficiency for mixed workloads. Purpose-built flash architecture delivers sub-millisecond response times with greater efficiency than other hybrid arrays.
Scale-to-fit. Scale up seamlessly to grow the performance and capacity of the array. Scale across multiple arrays non-
disruptively in a cluster still managed as one.
Adaptive service levels. Assign and change the service level of any volume at the click of a button ("Auto Flash", "All Flash
or "Minimal Flash").
Proactive resolution. InfoSight automatically predicts and resolves 86% of problems5 before you even know there is an issue.
Solves storage and non-storage problems. By collecting and correlating sensors across the infrastructure stack, InfoSight
uncovers problems spanning from storage to VMs. In fact, 54% of the problems InfoSight resolves are outside of storage
Prevents known issues with infrastructure that learns. If a problem is detected in one system, InfoSight begins to predict
the issue and inoculate other systems. Every system gets smarter and more reliable through collective installed base insights.
The support you’ve always wanted. Automation and proactive resolution put the focus on prevention, streamlining the
6
.
Flash-optimized write performance. Defy expectations and write to disk at flash speeds through write serialization to get flash-like performance from very cost-efficient, high-density hard disk drives.
Flash-optimized read performance. Dynamic flash caching accelerates reads even as workloads change to leverages flash
7
capacity more efficiently
than other tiered hybrid systems.
Always-on data reduction. Variable-block compression, zero pattern elimination, thin provisioning, and zero-copy clones
Greater than 99.9999% measured availability
. Predictive analytics and fault-
six-nines of proven availability, validated across the installed base.
Triple+ Parity RAID. Tolerates three simultaneous drive failures plus additional protection from intra-drive parity.
SmartSecure encryption. Application-granular, FIPS-certified encryption and data shredding provide end-to-end security
for data at rest and on-the-wire when replicated offsite.
Integrated data protection. An ideal foundation for comprehensive data protection through application-consistent
Based on actual customer data collected by the Nimble Storage support organization as of March 2017. Refer to the
Based on actual customer data collected by the Nimble Storage support organization as of March 2017. Refer to the Nimble
Response times based on actual customer data collected by the Nimble Storage Support organization as of March 2017.
The Nimble Operating System (NOS) is built to optimize the use of system resources including the CPU and memory. This
Redefining the Standard for System Availability for additional details (registration required).
Can Machine Learning Prevent Application Downtime?
write serialization, dynamic flash caching of reads,
-on data reduction without affecting the storage performance that is delivered.
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Overview
Page 3
Nimble Storage CS1000H
Nimble Storage CS1000
Number of controllers
2
Number of drives
(11) LFF Hard Drives4
(21) LFF Hard Drives
Usable capacity in base array1
7 TB
16 TB
33 TB
480 GB or 960 GB
depending on configuration
Expansion Shelves
Up to (6) Expansion Shelves5
RAID level
Triple+ Parity RAID
On-board connectivity
(4) 1 GbE/10 GbE ports, (2) per controller
(4) 1 GbE iSCSI, or
depending on configuration
Expansion Shelves for Nimble Storage Adaptive Flash Arrays
CS Expansion Shelf with 21 TB
CS Expansion Shelf with 42 TB
Number of drives
(21) drives
Raw capacity in expansion shelf1
21 TB
42 TB
Usable capacity in expansion shelf1
16 TB
33 TB
Effective capacity in expansion shelf
1, 2
32 TB
66 TB
Flash Capacity3
720 GB
1200 GB
RAID level
Triple+ Parity RAID
Host OS Support
Microsoft® Windows® Server, including Microsoft® Hyper-V™ | VMware vSphere™ | Ubuntu
SUSE® Linux Enterprise | SUSE® Linux Virtualization | Red Hat® Enterprise Linux® | Red Hat® Enterprise Virtualization
CentOS | Oracle® Linux® (UEK and RHEL compatible kernels) | Oracle® Solaris Citrix® | IBM® AIX®
For the latest information on supported operating systems refer to Single Point of Connectivity Knowledge (SPOCK) for HPE
http://www.hpe.com/storage/spock
Raw capacity in base array1 11 TB 21 TB 42 TB
Effective capacity in base array
Flash Capacity3
Additional host connectivity
1, 2
13 TB 32 TB 66 TB
1.44 TB 2.88 TB
(4) 1/10GbE iSCSI (10GBASE-T), or
(4) 1/10GbE iSCSI (Optical), or
(4) 8/16Gb Fibre Channel;
NOTE: Specifications are subject to change without notice.
1
For storage capacity, 1 GiB = 230 bytes and 1 TiB = 1,024 GiB.
2
Assuming 2:1 data reduction with compression.
3
Flash Capacity is provided by Solid State Drives, upgradable with Flash Upgrade Kits.
4
Included in base array, upgradable to (22) drives.
5
Requires upgrade to (22) drives in the CS1000H base array before connecting expansion shelves.
Storage products, including Nimble Storage:
QuickSpecs
Nimble Storage Adaptive Flash Arrays

Service and Support and Warranty Information

Page 4
Warranty
Nimble Storage arrays come with the following warranties:
NOTE: Warranty is provided Nimble Storage, an HPE company.
Service and Support
Support is required for all Nimble Storage arrays. Support SKUs provide three years of 24x7 telephone
Installation Service
*NOTE: Available in select markets; for areas not currently covered, Nimble Storage offers on-site spare parts/kits for purchase
1 year, parts-only warranty for hardware components
90 day, software updates for defects
Additionally, Nimble Storage will provide phone support for replacing a defective part. Additional support coverage is required for Nimble Storage arrays.
and email support for the arrays with a choice of Next Business Day (NBD) or 4-hour parts delivery*, access to Nimble Storage’s InfoSight Predictive Analytics platform and software updates.
NOTE: Support contract is mandatory for all Nimble Storage products.
New Array Installation (USA/Canada only)
On-site installation of a new Nimble Storage array in a data center.
New Remote Installation
Remote installation of a new Nimble Storage array in a data center.
Upgrade Kit or Expansion Shelf Installation (USA/Canada only)
On-site installation of upgrades kits or expansion shelves for an existing Nimble Storage array.
NOTE: Installation services are optional for all Nimble Storage products.
Loading...
+ 9 hidden pages