Hewlett Packard Enterprise Q2Q28A, Q8H39A Getting Started Guide

QuickSpecs
Nimble Storage Adaptive Flash Arrays

Overview

Page 1
Nimble Storage Adaptive Flash Arrays
Nimble Storage Adaptive Flash Arrays from Nimble Storage, a Hewlett Packard Enterprise company, are the industry’s only predictive hybrid flash platform. This is achieved by combining a flash access to data with
Nimble Storage CS1000 and CS1000H Adaptive Flash Arrays are the hybrid entry point to the Nimble Predictive Cloud platform, providing value and simplicity for mixed, mainstream workloads. They comb resiliency at an economical price point. The arrays allow you to start small and scale up to 294
Since they are backed by our Timeless Storage guarantee become a thing of the past.
Designed to radically simplify operations, Nimble Storage Adaptive Flash Arrays feature InfoSight prevent issues across the infrastructu collected the necessary information to solve the problem, removing the need for complex troubleshooting. As a result, traditi level 1 and 2 support staff is compl level 3 experts who answer calls in less than a minute on average.
NOTE:
Nimble
Nimble Storage CS1000 Adaptive Flash Array4
3 bays hold Dual Flash Carriers with Small Form Factor SSDs)
NOTE:
1
2
Refer to the whitepaper
3
Subject to Nimble Storage General Terms and Conditions available at
4
2 bays holding Dual Flash Carriers with SFF Solid State Drives.
arrays1 delivering radical simplicity with consistently good performance within a scalable, cloud-ready
-optimized architecture with InfoSight Predictive Analytics—giving you fast, reliable
proven, measured availability of greater than 99.9999%2.
ine a flash-optimized architecture, scalability and
3
, there is no need to pay for optional software, and forklift upgrades can
re stack. Even the most complex issues are rapidly resolved because InfoSight has already
etely automated by InfoSight. The Nimble Storage support organization is entirely comprised of
For more information about the entire Nimble Storage product portfolio, go to http://www.nimblestorage.com.
Storage products are not available in some markets.
TB raw capacity with the CS1000.
Predictive Analytics, predict and
onal
(Base array, 4U; 21 bays hold carriers with Large Form Factor HDDs,
Based on publicly available information as of May 2017. Based on actual customer data collected by the Nimble Storage support organization as of March 2017.
Redefining the Standard for System Availability for additional details (registration required).
Refer to https://www.nimblestorage.com/satisfaction-guarantee/ for details.
http://www.nimblestorage.com/docs.
Nimble Storage CS1000H Adaptive Flash Array (not shown) has 22 bays holding LFF Hard drives and
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Overview
Page 2
Flash Performance for Mixed, Mainstream Workloads
",
Cloud-ready. Flexibility to create a multicloud environment with Nimble Cloud Volumes.
InfoSight Predictive Analytics
process, and connecting you directly to support expertise. No more answering routine support questions, sending log files, or attempting to recreate issues.
Unparalleled Hybrid Efficiency
deliver up to 2-3X space savings without performance penalty8.
Absolute Resiliency
Error! Bookmark not defined.
tolerant design achieve over
snapshots and replication as well as integration with leading backup software solutions.
NOTE:
5
whitepaper
6
Labs Research Report
7
Efficiency comparisons based on a combination of technologies including and the use of 3D NAND flash.
8
enables the arrays to provide Always
Nimble Storage Adaptive Flash Array models
Speed and efficiency for mixed workloads. Purpose-built flash architecture delivers sub-millisecond response times with greater efficiency than other hybrid arrays.
Scale-to-fit. Scale up seamlessly to grow the performance and capacity of the array. Scale across multiple arrays non-
disruptively in a cluster still managed as one.
Adaptive service levels. Assign and change the service level of any volume at the click of a button ("Auto Flash", "All Flash
or "Minimal Flash").
Proactive resolution. InfoSight automatically predicts and resolves 86% of problems5 before you even know there is an issue.
Solves storage and non-storage problems. By collecting and correlating sensors across the infrastructure stack, InfoSight
uncovers problems spanning from storage to VMs. In fact, 54% of the problems InfoSight resolves are outside of storage
Prevents known issues with infrastructure that learns. If a problem is detected in one system, InfoSight begins to predict
the issue and inoculate other systems. Every system gets smarter and more reliable through collective installed base insights.
The support you’ve always wanted. Automation and proactive resolution put the focus on prevention, streamlining the
6
.
Flash-optimized write performance. Defy expectations and write to disk at flash speeds through write serialization to get flash-like performance from very cost-efficient, high-density hard disk drives.
Flash-optimized read performance. Dynamic flash caching accelerates reads even as workloads change to leverages flash
7
capacity more efficiently
than other tiered hybrid systems.
Always-on data reduction. Variable-block compression, zero pattern elimination, thin provisioning, and zero-copy clones
Greater than 99.9999% measured availability
. Predictive analytics and fault-
six-nines of proven availability, validated across the installed base.
Triple+ Parity RAID. Tolerates three simultaneous drive failures plus additional protection from intra-drive parity.
SmartSecure encryption. Application-granular, FIPS-certified encryption and data shredding provide end-to-end security
for data at rest and on-the-wire when replicated offsite.
Integrated data protection. An ideal foundation for comprehensive data protection through application-consistent
Based on actual customer data collected by the Nimble Storage support organization as of March 2017. Refer to the
Based on actual customer data collected by the Nimble Storage support organization as of March 2017. Refer to the Nimble
Response times based on actual customer data collected by the Nimble Storage Support organization as of March 2017.
The Nimble Operating System (NOS) is built to optimize the use of system resources including the CPU and memory. This
Redefining the Standard for System Availability for additional details (registration required).
Can Machine Learning Prevent Application Downtime?
write serialization, dynamic flash caching of reads,
-on data reduction without affecting the storage performance that is delivered.
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Overview
Page 3
Nimble Storage CS1000H
Nimble Storage CS1000
Number of controllers
2
Number of drives
(11) LFF Hard Drives4
(21) LFF Hard Drives
Usable capacity in base array1
7 TB
16 TB
33 TB
480 GB or 960 GB
depending on configuration
Expansion Shelves
Up to (6) Expansion Shelves5
RAID level
Triple+ Parity RAID
On-board connectivity
(4) 1 GbE/10 GbE ports, (2) per controller
(4) 1 GbE iSCSI, or
depending on configuration
Expansion Shelves for Nimble Storage Adaptive Flash Arrays
CS Expansion Shelf with 21 TB
CS Expansion Shelf with 42 TB
Number of drives
(21) drives
Raw capacity in expansion shelf1
21 TB
42 TB
Usable capacity in expansion shelf1
16 TB
33 TB
Effective capacity in expansion shelf
1, 2
32 TB
66 TB
Flash Capacity3
720 GB
1200 GB
RAID level
Triple+ Parity RAID
Host OS Support
Microsoft® Windows® Server, including Microsoft® Hyper-V™ | VMware vSphere™ | Ubuntu
SUSE® Linux Enterprise | SUSE® Linux Virtualization | Red Hat® Enterprise Linux® | Red Hat® Enterprise Virtualization
CentOS | Oracle® Linux® (UEK and RHEL compatible kernels) | Oracle® Solaris Citrix® | IBM® AIX®
For the latest information on supported operating systems refer to Single Point of Connectivity Knowledge (SPOCK) for HPE
http://www.hpe.com/storage/spock
Raw capacity in base array1 11 TB 21 TB 42 TB
Effective capacity in base array
Flash Capacity3
Additional host connectivity
1, 2
13 TB 32 TB 66 TB
1.44 TB 2.88 TB
(4) 1/10GbE iSCSI (10GBASE-T), or
(4) 1/10GbE iSCSI (Optical), or
(4) 8/16Gb Fibre Channel;
NOTE: Specifications are subject to change without notice.
1
For storage capacity, 1 GiB = 230 bytes and 1 TiB = 1,024 GiB.
2
Assuming 2:1 data reduction with compression.
3
Flash Capacity is provided by Solid State Drives, upgradable with Flash Upgrade Kits.
4
Included in base array, upgradable to (22) drives.
5
Requires upgrade to (22) drives in the CS1000H base array before connecting expansion shelves.
Storage products, including Nimble Storage:
QuickSpecs
Nimble Storage Adaptive Flash Arrays

Service and Support and Warranty Information

Page 4
Warranty
Nimble Storage arrays come with the following warranties:
NOTE: Warranty is provided Nimble Storage, an HPE company.
Service and Support
Support is required for all Nimble Storage arrays. Support SKUs provide three years of 24x7 telephone
Installation Service
*NOTE: Available in select markets; for areas not currently covered, Nimble Storage offers on-site spare parts/kits for purchase
1 year, parts-only warranty for hardware components
90 day, software updates for defects
Additionally, Nimble Storage will provide phone support for replacing a defective part. Additional support coverage is required for Nimble Storage arrays.
and email support for the arrays with a choice of Next Business Day (NBD) or 4-hour parts delivery*, access to Nimble Storage’s InfoSight Predictive Analytics platform and software updates.
NOTE: Support contract is mandatory for all Nimble Storage products.
New Array Installation (USA/Canada only)
On-site installation of a new Nimble Storage array in a data center.
New Remote Installation
Remote installation of a new Nimble Storage array in a data center.
Upgrade Kit or Expansion Shelf Installation (USA/Canada only)
On-site installation of upgrades kits or expansion shelves for an existing Nimble Storage array.
NOTE: Installation services are optional for all Nimble Storage products.
QuickSpecs
Nimble Storage Adaptive Flash Arrays

Configuration Information

Page 5
Nimble Storage Adaptive Flash Arrays
All Nimble Storage Adaptive Flash Arrays come in a 4U form-factor chassis with
Nimble Storage CS1000H Adaptive Flash Array
The Nimble Storage CS1000H Adaptive Flash Arrays come with (11) LFF Hard Drives included as standard and supports (2) Dual
(22) 1 TB drives, and by connecting up to (6) expansion shelves to the base array.
Base Array
Nimble Storage CS1000H 2x1GbE 11x1TB HDD 2x240GB Flash Array
Nimble Storage CS1000H 11TB 480GB Flash 3yr 4hr Support
Q2Q14A
Nimble Storage CS1000H 2x10GbE 11x1TB HDD 2x480GB Flash Array
Nimble Storage CS1000H 11TB 960GB Flash 3yr 4hr Support
Q2Q15A
Nimble Storage CS1000H 2x10GbE 11x1TB HDD 2x240GB Flash Array
Nimble Storage CS1000H 11TB 480GB Flash 3yr 4hr Support
Q2Q16A
Nimble Storage CS1000H 2x10GBASE-T 11x1TB HDD 2x480GB Flash Array
Nimble Storage CS1000H 11TB 960GB Flash 3yr 4hr Support
Q2Q17A
Nimble Storage CS1000H 2x10GBASE-T 11x1TB HDD 2x240GB Flash Array
Nimble Storage CS1000H 11TB 480GB Flash 3yr 4hr Support
Q2Q18A
Nimble Storage CS1000H 2x16Gb FC 11x1TB HDD 2x480GB Flash Array
Disk configuration: (11) 1 TB HDDs
Q2Q19A
(2) controllers with fans and NVDIMM,
(4) 1GbE/10GbE network ports, i.e. (2) per controller, for iSCSI or management traffic and
(2) power supplies.
Additional host connectivity per controller is indicated in the product descriptions below. Flash Cache upgrades and expansion shelves are available for integration in the field.
Flash Carriers with SFF Solid State Drives. The configurations below include two SFF SSDs and accept one optional Flash Upgrade Kit to increase the Flash Cache. Additional drives can be installed into the array as field upgrade, bringing the total drive count to
Includes base with the following
Disk configuration: (11) 1 TB HDDs
Flash configuration: (2) 240 GB SSDs
Additional connectivity: (2) 1GbE iSCSI ports per controller
Requires Nimble Storage CS1000H 11TB 480GB Flash 3yr NBD Support or
Includes base with the following
Disk configuration: (11) 1 TB HDDs
Flash configuration: (2) 480 GB SSDs
Additional connectivity: (2) 10GbE Optical iSCSI ports per controller
Requires Nimble Storage CS1000H 11TB 960GB Flash 3yr NBD Support or
Includes base with the following
Disk configuration: (11) 1 TB HDDs
Flash configuration: (2) 240 GB SSDs
Additional connectivity: (2) 10GbE Optical iSCSI ports per controller
Requires Nimble Storage CS1000H 11TB 480GB Flash 3yr NBD Support or
Includes base with the following
Disk configuration: (11) 1 TB HDDs
Flash configuration: (2) 480 GB SSDs
Additional connectivity: (2) 10GbE iSCSI (10GBASE-T) ports per controller
Requires Nimble Storage CS1000H 11TB 960GB Flash 3yr NBD Support or
Includes base with the following
Disk configuration: (11) 1 TB HDDs
Flash configuration: (2) 240 GB SSDs
Additional connectivity: (2) 10GbE iSCSI (10GBASE-T) ports per controller
Requires Nimble Storage CS1000H 11TB 480GB Flash 3yr NBD Support or
Includes base with the following
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Configuration Information
Page 6
Flash configuration: (2) 480 GB SSDs
Nimble Storage CS1000H 11TB 960GB Flash 3yr 4hr Support
Upgrades
Nimble Storage CS1000H 11x1TB HDD Upgrade Kit
HDD Upgrade Kit 3yr 4hr Support
Q2Q20A
Nimble Storage CS1000H 2x240GB Flash Upgrade Kit
CS1000H Flash Upgrade Kit 3yr 4hr Support
Q2Q21A
Nimble Storage CS1000H 2x480GB Flash Upgrade Kit
Q2Q22A
Support options
Nimble Storage CS1000H 11TB 480GB Flash 3yr NBD Support
Q2Q64A
Nimble Storage CS1000H 11TB 960GB Flash 3yr NBD Support
Q2Q65A
Nimble Storage CS1000H 11TB 480GB Flash 3yr 4hr Support
Q2Q66A
Nimble Storage CS1000H 11TB 960GB Flash 3yr 4hr Support
Q2Q67A
Nimble Storage CS1000H HDD Upgrade Kit 3yr NBD Support
Q2Q68A
Nimble Storage CS1000H HDD Upgrade Kit 3yr 4hr Support
Q2Q69A
Nimble Storage CS1000H Flash Upgrade Kit 3yr NBD Support
Q2Q70A
Nimble Storage CS1000H Flash Upgrade Kit 3yr 4hr Support
Q2Q71A
Additional connectivity: (2) 8/16Gb FC ports per controller
Requires Nimble Storage CS1000H 11TB 960GB Flash 3yr NBD Support or
(optional)
Adds another (11) 1 TB drives to the CS1000H base array. Requires at least 960 GB Flash Cache in the base array, and Nimble Storage CS1000H HDD Upgrade Kit 3yr NBD Support or Nimble Storage CS1000H
Adds (2) 240 GB SSD as Flash Cache to an existing CS1000H base array. Requires Nimble Storage CS1000H Flash Upgrade Kit 3yr NBD Support or Nimble Storage
Adds (2) 480 GB SSD as Flash Cache to an existing CS1000H base array. Requires Nimble Storage CS1000H Flash Upgrade Kit 3yr NBD Support or Nimble Storage CS1000H Flash Upgrade Kit 3yr 4hr Support
(mandatory)
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Configuration Information
Page 7
Nimble Storage CS1000 Adaptive Flash Array
All Nimble Storage CS1000 Adaptive Flash Arrays come with (21) LFF Hard Drives included as standard and supports (3) Dual
SFF SSDs and accept one optional Flash Upgrade
Kit to increase the Flash Cache. Additional capacity can be added by connecting up to (6) expansion shelves to the base array.
Base Array
Nimble Storage CS1000 2x10GbE 21x1TB HDD 3x480GB Flash Array
Q2Q23A
Nimble Storage CS1000 2x1GbE 21x1TB HDD 3x480GB Flash Array
Nimble Storage CS1000 21TB 3yr 4hr Support
Q2Q24A
Nimble Storage CS1000 2x10GBASE-T 21x1TB HDD 3x480GB Flash Array
Q2Q25A
Nimble Storage CS1000 2x16Gb FC 21x1TB HDD 3x480GB Flash Array
Q2Q26A
Nimble Storage CS1000 2x16Gb FC 21x2TB HDD 3x960GB Flash Array
Nimble Storage CS1000 42TB 3yr 4hr Support
Q2Q27A
Nimble Storage CS1000 2x10GbE 21x2TB HDD 3x960GB Flash Array
Q2Q28A
Nimble Storage CS1000 2x10GBASE-T 21x2TB HDD 3x960GB Flash Array
Q2Q29A
Nimble Storage CS1000 3x240GB Flash Upgrade Kit
Q2Q30A
Flash Carriers with SFF Solid State Drives. The configurations below include three
Includes base with the following
Disk configuration: (21) 1 TB HDDs
Flash configuration: (3) 480 GB SSDs
Additional connectivity: (2) 10GbE Optical iSCSI ports per controller
Requires Nimble Storage CS1000 21TB 3yr NBD Support or Nimble Storage CS1000 21TB 3yr 4hr Support
Includes base with the following
Disk configuration: (21) 1 TB HDDs
Flash configuration: (3) 480 GB SSDs
Additional connectivity: (2) 1GbE iSCSI ports per controller
Requires Nimble Storage CS1000 21TB 3yr NBD Support or
Includes base with the following
Disk configuration: (21) 1 TB HDDs
Flash configuration: (3) 480 GB SSDs
Additional connectivity: (2) 10GbE iSCSI (10GBASE-T) ports per controller
Requires Nimble Storage CS1000 21TB 3yr NBD Support or Nimble Storage CS1000 21TB 3yr 4hr Support
Includes base with the following
Disk configuration: (21) 1 TB HDDs
Flash configuration: (3) 480 GB SSDs
Additional connectivity: (2) 8/16Gb FC ports per controller
Requires Nimble Storage CS1000 21TB 3yr NBD Support or Nimble Storage CS1000 21TB 3yr 4hr Support
Includes base with the following
Disk configuration: (21) 2 TB HDDs
Flash configuration: (3) 960 GB SSDs
Additional connectivity: (2) 8/16Gb FC ports per controller
Requires Nimble Storage CS1000 42TB 3yr NBD Support or
Includes base with the following
Disk configuration: (21) 2 TB HDDs
Flash configuration: (3) 960 GB SSDs
Additional connectivity: (2) 10GbE Optical iSCSI ports per controller
Requires Nimble Storage CS1000 42TB 3yr NBD Support or Nimble Storage CS1000 42TB 3yr 4hr Support
Includes base with the following
Disk configuration: (21) 2 TB HDDs
Flash configuration: (3) 960 GB SSDs
Additional connectivity: (2) 10GbE iSCSI (10GBASE-T) ports per controller
Requires Nimble Storage CS1000 42TB 3yr NBD Support or Nimble Storage CS1000 42TB 3yr 4hr Support
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Configuration Information
Page 8
Upgrades
Includes (3) 240 GB SSD for CS1000, requires Nimble Storage CS1000 Flash Upgrade Kit 3yr NBD Support or Nimble Storage CS1000 Flash Upgrade Kit 3yr 4hr Support
Nimble Storage CS1000 3x480GB Flash Upgrade Kit
3yr NBD Support or Nimble Storage CS1000 Flash Upgrade Kit 3yr 4hr Support
Q2Q31A
Support
Nimble Storage CS1000 21TB 3yr NBD Support
Q2Q72A
Nimble Storage CS1000 21TB 3yr 4hr Support
Q2Q73A
Nimble Storage CS1000 42TB 3yr NBD Support
Q2Q74A
Nimble Storage CS1000 42TB 3yr 4hr Support
Q2Q75A
Nimble Storage CS1000 Flash Upgrade Kit 3yr NBD Support
Q2Q76A
Nimble Storage CS1000 Flash Upgrade Kit 3yr 4hr Support
Q2Q77A
(optional)
Includes (3) 480 GB SSD for CS1000, requires Nimble Storage CS1000 Flash Upgrade Kit
(mandatory)
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Configuration Information
Page 9
Options for Nimble Storage Adaptive Flash Arrays
Additional capacity can be added to an existing Nimble Storage Adaptive Flash Array by connecting expansion shelves.
expansion shelves can be connected to the array.
Expansion Shelves
Nimble Storage CS 21x1TB HDD 3x240GB Flash Expansion Shelf
4hr Support
Q2Q32A
Nimble Storage CS 21x2TB HDD 2x480GB and 1x240GB Flash Expansion Shelf
4hr Support
Q2Q33A
Support
Nimble Storage CS 21TB Expansion Shelf 3yr NBD Support
Q2Q78A
Nimble Storage CS 21TB Expansion Shelf 3yr 4hr Support
Q2Q80A
Nimble Storage CS 42TB Expansion Shelf 3yr NBD Support
Q2Q79A
Nimble Storage CS 42TB Expansion Shelf 3yr 4hr Support
Q2Q81A
NOTE: The CS1000H base array needs to be upgraded to (22) drives and the required amount of Flash Capacity before
Capacity expansion shelf with 21TB raw capacity and Flash Cache, requires Nimble Storage CS 21TB Expansion Shelf 3yr NBD Support or Nimble Storage CS 21TB Expansion Shelf 3yr
Capacity expansion shelf with 42TB raw capacity and Flash Cache, requires Nimble Storage CS 42TB Expansion Shelf 3yr NBD Support or Nimble Storage CS 42TB Expansion Shelf 3yr
(mandatory)
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Configuration Information
Page 10
Installation Services
Installation services accelerate the installation and startup: Nimble Storage Pro Installation Services provide rapid planning,
NOTE:
Nimble Storage Upgrade Kit/Expansion Shelf Installation Service
Q2R14A
Nimble Storage New Array Installation Service
Q2R15A
Nimble Storage New Array Remote Installation Service
Q2R16A
Nimble Storage Additional Array Installation Service
Q2R17A
Racks
Nimble Storage arrays and expansion shelves are compatible with industry standard 4-post EIA 19 inch racks with square
http://h18004.www1.hpe.com/products/servers/proliantstorage/power-protection/pdu.html
installation, and validation of Nimble Storage arrays into your environment
On-site installation services are only available in the USA and Canada; installation services are optional.
mounting holes, including HPE 36U, 42U and 47U Enterprise Shock Racks.
For more information on the HPE rack offerings, please see the following URL:
http://h18004.www1.hpe.com/products/servers/platforms/rackandpower.html
For more information on rack options, see:
http://www.hpe.com/products/rackoptions.
For more information on PDUs, see:
.
QuickSpecs
Nimble Storage Adaptive Flash Arrays

Technical Specifications

Page 11
Physical Dimensions
Width in/mm
Depth in/mm
Height in/mm/U
Weight lb/kg
17.5/445
26.5/673
7/175/4
90/41
Nimble Storage CS1000H
15/381
21/533
15/381
15/7
17.5/445
26.5/673
7/175/4
105/48
17.5/445
26.5/673
7/175/4
90/41
Nimble Storage CS Series Flash Upgrade Kits
12/305
12/305
7/175
3/2
Power Requirements
Nimble Storage CS1000H
Nimble Storage CS1000
Input Voltage
AC PCM option
100 to 240 VAC (50 to 60 Hz)
Max power requirements (Watts/kVA)
500 W / 0.56 kVA
600 W / 0.56 kVA
Thermal (BTU)
1638 BTU
1965 BTU
Environmental Specifications
4
Operating Temperature
10 - 35° C (50 - 95° F)
Shipping Temperature
0° C - 40° C (32° F - 104° F) Maximum rate of change is 20°C/hr (36°F/hr)
Operating Altitude (ft/m) max.
10,000 ft / 3,048 m
Shipping Altitude (ft/m) max.
40,000ft/ 12,192 m
Humidity
8 - 90%, non-condensing
Shipping Humidity
5 - 95%, non-condensing
Operating Vibration
0.25 G, Sine 5 - 200 Hz (approx. 15 min/axis);
0.4 GRMS, Random 5 - 200 Hz (approx. 60 min/axis)
Non-operating Vibration
0.5 G, Sine 5 - 200 Hz (approx. 15 min/axis);
0.98 GRMS, Random 5 - 500Hz (approximate 30 min/axis)
Operating Shock
20 G, 2.5ms, half-sine, one shock on each side
Non-operating Shock
20 G, 10ms, square wave, one shock on each side
Nimble Storage CS1000H
11TB HDD Upgrade Kit
Nimble Storage CS1000
Nimble Storage CS1000 Expansion Shelves
Reduce rating by 1° F for each 1000 ft altitude (1.8° C/1,000 m)
QuickSpecs
Nimble Storage Adaptive Flash Arrays
Technical Specifications
Page 12
Electromagnetic Compatibility
Subpart B of Part 15 of FCC Rules for Class A digital devices
Acoustics Sound pressure level
Fan Speed (RPM)
Standard Speed (3540 RPM)
Full Speed (13000 RPM)
Front
65.5
72.0
Back
71.2
75.8
Left
65.6
69.0
Right
65.6
70.7
Safety
EN60950-1:2005 (Second Edition); Am1:2009 + Am2:2013
SANS IEC 60950-1
NOTE: 4 Specifications are subject to change without notice.
Certifications / Markings
UL
CCC Exemption
NOM MoEc NBTC SDoC CITC/CoC* EAC BIS LOA (S. Africa) RoHS 2011/65/EU, EN50581:2012 WEEE
measured per ISO 7779 specs during normal operating fan
ICES-003, Issue 6, dated January 2016 (Class A) VCCI V-3: April 2014 (Class A) EN 55022:2010 CISPR 22:2008 AS/NZS CISPR 22:2009 +A1:2010 EN55032:2012 CISPR 32:2012 EN 55024:2010 CISPR 24:2010 +A1:2015 TCVN 7189:2009 NBTC TS 3001-2555 TP TC 020/2011
IEC 60950-1:2005 (Second Edition); Am1:2009 + Am2:2013 EN60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013 UL/IEC 60960-1 2nd Ed. Am1 + Am2 CNS14336-1 (’99) CNS13438 (’95) NOM-019-SCFI-1998 NBTC TS 4001-2550 TP TC 004/2011 IS 13252 (PART 1):2010 +A1:2013 + A2:2-15
cUL CE FCC Class A IC Class A VCCI Class A RCM BSMI Class A KC
QuickSpecs
Nimble Adaptive Flash Arrays

Summary of Changes

Page 13
Date
Version History
Action
Description of Change
5-Jun-2017
Version 1
Created
Created first version, including CS1000 and CS1000H
Sign up for updates
© Copyright 2017 Hewlett Packard Enterprise Development LP. The information contained herein is subject to change without notice. The only warranties for services are set forth in the express warranty statements accompanying such pr
Nothing herein should be construed as constituting an additional warranty. shall not be liable for technical or editorial errors or omissions contained herein.
a00008274enw
Hewlett Packard Enterprise products and
- 15933 - Worldwide - V1 – 05-June-2017
oducts and services.
Hewlett Packard Enterprise
Loading...