Hewlett Packard Enterprise AP105SDR User Manual

IAP-105 Wireless Access Point
AP105_005
AP105_001
105
PWR
ENET
11B/G/N
11A/N
!
!
AP105_002
CONSOLE
ENET
12V 1.25A
CONSOLE
ENET
Power Connector

Reset Button

!
!
!
AP105_003
AP105_004
Installation Guide

About the Aruba IAP-105 Access Point

The Aruba IAP-105 wireless access point supports the IEEE 802.11n standard for high-performance WLAN. This access point uses MIMO (Multiple-in, Multiple­out) technology and other high-throughput mode techniques to deliver high­performance, 802.11n 2.4 GHz and 5 GHz functionality while simultaneously supporting existing 802.11a/b/g wireless services.
The Aruba IAP-105 access point provides the following capabilities:
Wireless transceiverProtocol-independent networking functionalityIEEE 802.11a/b/g/n operation as a wireless access pointIEEE 802.11a/b/g/n operation as a wireless air monitorCompatibility with IEEE 802.3af PoE

Package Contents

IAP-105 access pointInstallation guide (this document)Aruba Instant Quick Start Guide
Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials. Use these materials to repack and return the unit to the supplier if needed.
Figure 3 IAP-105 Rear

Console Port

IAP Pre-Installation Checklist

Before installing your IAP-105 access point, be sure that you have the following:
CAT5 UTP cable of required lengthOne of the following power sources:
IEEE 802.3af-compliant Power over Ethernet (PoE) sourceThe POE source can be any power source equipment (PSE) Aruba IAP AC-DC adapter kit (sold separately)

Summary of the Setup Process

Successful setup of an IAP-105 access point consists of five tasks, which must be performed in this order:
1. Identify the specific installation location for each IAP.
2. Install each IAP.
3. Verify post-installation connectivity.
4. Configure each IAP.
Aruba Networks, Inc., in compliance with governmental requirements, has designed the IAP-105 access points so that only authorized network administrators can change the settings. For more information about IAP configuration, refer to the Aruba Instant Quick Start Guide and Aruba Instant User Guide.

Installing the IAP

Service to all Aruba Networks products should be performed by trained service personnel only.

Using the Integrated Wall-Mounting Slots

The keyhole-shaped slots on the back of the IAP can be used to attach the device upright to an indoor wall or shelf. When you choose the mounting location, allow additional space at the right of the unit for cables.
1. Since the ports are on the back of the device, make sure that you mount the IAP in such a way that there is a clear path to the Ethernet port, such as a pre­drilled hole in the mounting surface.
2. At the mounting location, install two screws on the wall or shelf, 1 7/8 inches (4.7 cm) apart. If you are attaching the device to drywall, Aruba recommends using appropriate wall anchors (not included).
3. Align the mounting slots on the rear of the IAP over the screws and slide the unit into place (see Figure 4).
Figure 4 Installing the IAP-105 Access Point on a Wall
Figure 1 IAP-105

IAP-105 Hardware Overview

Figure 2 IAP-105 Front
Use the console port to connect to a terminal for direct local management.

Ethernet Port

IAP-105 is equipped with a single 10/100/1000Base-T (RJ-45) auto-sensing, MDI/ MDX wired-network connectivity port. This port supports IEEE 802.3af Power over Ethernet (PoE) compliance, accepting 48VDC as a standard defined Powered Device (PD) from a Power Sourcing Equipment (PSE) such as a PoE midspan injector, or network infrastructure that supports PoE.

DC Power Socket

If PoE is not available, an optional Aruba IAP AC-DC adapter kit (sold separately) can be used to power the IAP-105.
Reset Button
The reset button can be used to return the IAP to factory default settings. If you have converted your IAP to a campus AP, pressing the reset button converts it back to an IAP. To reset the IAP:
1. Power off the IAP.
2. Press and hold the reset button using a small, narrow object, such as a paperclip.
3. Power-on the IAP without releasing the reset button. The power LED will flash within 5 seconds.
4. Release the reset button.
The power LED will flash again within 15 seconds indicating that the reset is completed. The IAP will now continue to boot with the factory default settings.
Access points are radio transmission devices and as such are subject to governmental regulation. Network administrators responsible for the configuration and operation of access points must comply with local broadcast regulations. Specifically, access points must use channel assignments appropriate to the location in which the access point will be used.

Identifying Specific Installation Locations

RF Radiation Exposure Statement: This equipment complies with FCC
RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems.
You can mount the IAP-105 access point on a wall or on the ceiling. Each location should be as close as possible to the center of the intended coverage area and should be free from obstructions or obvious sources of interference. These RF absorbers/reflectors/interference sources will impact RF propagation and should have been accounted for during the planning phase and adjusted for in VisualRF.

Identifying Known RF Absorbers/Reflectors/Interference Sources

Using the Integrated Ceiling Tile Rail Slots

The snap-in tile rail slots on the rear of the IAP can be used to securely attach the device directly to a 15/16" wide, standard ceiling tile rail.
Make sure the IAP fits securely on the ceiling tile rail when hanging the device from the ceiling; poor installation could cause it to fall onto people or equipment.
1. Pull the necessary cables through a prepared hole in the ceiling tile near where the IAP will be placed.
2. If necessary, connect the console cable to the console port on the back of the IAP.
Hold the IAP next to the ceiling tile rail with the ceiling tile rail mounting slots at approximately a 30-degree angle to the ceiling tile rail (see Figure 5). Make sure that any cable slack is above the ceiling tile.
Figure 5 Orienting the Ceiling Tile Rail Mounting Slots

LEDs

The IAP-105 is equipped with four LEDs that indicate the status of the various components of the IAP.
PWR: Indicates whether or not the IAP-105 is powered-onENET: Indicates the status of the IAP-105’s Ethernet port11A/N: Indicates the status of the 802.11a/n radio11B/G/N: Indicates the status of the 802.11b/g/n radio
For information about the IAP-105’s LED behavior, see Table 1 on page 2.

Before You Begin

FCC Statement: Improper termination of access points installed in the
United States (non-US Regulatory Domain model/s) will be in violation of the FCC grant of equipment authorization. Any such willful or intentional violation may result in a requirement by the FCC for immediate termination of operation and may be subject to forfeiture (47 CFR 1.80).
EU Statement: Lower power radio LAN product operating in 2.4 GHz and 5 GHz bands. Please refer to the Aruba Instant User Guide for details on restrictions.
Produit réseau local radio basse puissance operant dans la bande fréquence 2.4 GHz et 5 GHz. Merci de vous referrer au Aruba Instant User Guide pour les details des restrictions.
Low Power FunkLAN Produkt, das im 2.4 GHz und im 5 GHz Band arbeitet. Weitere Informationen bezlüglich Einschränkungen finden Sie im Aruba
Instant User Guide.
Apparati Radio LAN a bassa Potenza, operanti a 2.4 GHz e 5 GHz. Fare riferimento alla Aruba Instant User Guide per avere informazioni detagliate sulle restrizioni.
Identifying known RF absorbers, reflectors, and interference sources while in the field during the installation phase is critical. Make sure that these sources are taken into consideration when you attach an IAP to its fixed location.
RF absorbers include:
Cement/concrete—Old concrete has high levels of water dissipation, which
dries out the concrete, allowing for potential RF propagation. New concrete has high levels of water concentration within the concrete, blocking RF signals.
Natural Items—Fish tanks, water fountains, ponds, and treesBrick
RF reflectors include:
Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/
heating ducts, mesh windows, blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinets
Do not place an IAP between two air conditioning/heating ducts. Make sure
that APs are placed below ducts to avoid RF disturbances.
RF interference sources include:
Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones)Cordless headset such as those used in call centers or lunch rooms
3. Pushing toward the ceiling tile, rotate the IAP clockwise until the device clicks into place on the ceiling tile rail.

Connecting Required Cables

Install cables in accordance with all applicable local and national regulations and practices.

Ethernet Ports

The RJ45 Ethernet port (ENET) supports 10/100/1000Base-T auto-sensing MDI/ MDX connections. Use these ports to connect the IAP to a twisted pair Ethernet LAN segment. Use a 4- or 8-conductor, Category 5 UTP cable up to 100 m (325 feet) long.
The 10/100/1000 Mbps Ethernet port is on the back of the IAP. The port has an RJ-
1000Base-T Gigabit
Ethernet Port
RJ-45 Female Pin-Out
Signal Name
1 2 3 4 5 6 7 8
BI_DC+ BI_DC-
BI_DD+ BI_DD-
BI_DA+ BI_DA­BI_DB+
BI_DB-
Function
Bi-directional pair +C Bi-directional pair -C
Bi-directional pair +D Bi-directional pair -D
Bi-directional pair +A Bi-directional pair -A Bi-directional pair +B
Bi-directional pair -B
Serial
Console Port
1 2 3 4 5 6 7 8
TxD
GND RxD
RJ-45 Female Pin-Out
Direction
Input
Output
GND
3 4 5
2
5
63
RJ-45 DB-9
Internal
Connections
TxD
GND
RxD
1 2 3 4 5 6 7 8
TxD
GND RxD
RJ-45 Female
Pin-Out
Direction
Input
Output
DB-9 Male
Pin-Out
TxD
RxD
Ground
5 4 3 2 1
9 8 7 6
Direction
Input
Output
10
!
45 female connector with the pin-outs shown in Figure 6.
Figure 6 Gigabit Ethernet Port Pin-Out

Serial Console Port

The serial console port (Console) allows you to connect the IAP to a serial terminal or a laptop for direct local management. This port is an RJ-45 female connector with the pinouts described in Figure 7. Connect this port in one of the following ways:
Connect it directly to a terminal or terminal server using an Ethernet cable.Use a modular adapter to convert the RJ-45 (female) connector on the IAP to
a DB-9 (male) connector, and connect the adapter to a laptop using an RS-232 cable. See Figure 8 for connector details of the adapter.
Figure 7 Serial Port Pin-Out
Figure 8 RJ-45 (Female) to DB-9 (Male) Modular Adapter Conversion

Power Connection

The IAP-105 has a single 12V DC power jack socket to support powering through an AC-to-DC power adapter.
If both POE and DC power are available, the IAP uses POE even when there is not enough POE voltage available to power the IAP.

Verifying Post-Installation Connectivity

The integrated LEDs on the IAP can be used to verify that the IAP is receiving power and initializing successfully (see Table 1). Refer to the Aruba Instant Quick Start Guide for further details on verifying post-installation network connectivity.
Table 1 IAP-105 Series LED Meanings
LED Color/State Meaning
PWR Off No power to IAP
Green flashing System initializing
Red steady System failed to
initialize, contact TAC
Table 1 IAP-105 Series LED Meanings
LED Color/State Meaning
11B/G/N Off 2.4 GHz radio disabled
Amber 2.4 GHz radio enabled in
WLAN mode
Green 2.4 GHz radio enabled in
11n mode
Green flashing 2.4 GHz Air Monitor or
RF Protect mode

Product Specifications

Electrical

Ethernet:
1 x 10/100/1000Base-T auto-sensing Ethernet RJ-45 InterfacesMDI/MDXIEEE 802.3 (10Base-T), IEEE 802.3u (100Base-T). IEEE 802.3ab
(1000Base-T)
Power over Ethernet (IEEE 802.3af compliant), 48V DC/350mA (see Figure
6 for pin configuration)
Power: 12 VDC power interface, supports powering through an AC-to-DC
power adapter
If a power adapter other than the one provided by Aruba Networks is used in the US or Canada, it should be cULus (NRTL) Listed, with an output rated 12 VDC, minimum 1.25A, marked “LPS” or “Class 2,” and suitable for plugging into a standard power receptacle in the US and Canada.
For additional specifications on this product, please refer to the data sheet. The data sheet can be found at
www.arubanetworks.com.

Proper Disposal of Aruba Equipment

For the most current information about Global Environmental Compliance and Aruba products, see our website at

Waste of Electrical and Electronic Equipment

Aruba products at end of life are subject to separate collection and treatment in the EU Member States, Norway, and Switzerland and therefore are marked with the symbol shown at the left (crossed-out wheelie bin). The treatment applied at end of life of these products in these countries shall comply with the applicable national laws of countries implementing Directive 2002/96EC on Waste of Electrical and Electronic
Equipment (WEEE).

European Union RoHS

Aruba products also comply with the EU Restriction of Hazardous Substances Directive 2002/95/EC (RoHS). EU RoHS restricts the use of specific hazardous materials in
the manufacture of electrical and electronic equipment. Specifically, restricted materials under the RoHS Directive are Lead (including Solder used in printed circuit assemblies), Cadmium, Mercury, Hexavalent Chromium, and Bromine. Some Aruba products are subject to the exemptions listed in RoHS Directive Annex 7 (Lead in solder used in printed circuit assemblies). Products and packaging will be marked with the “RoHS” label shown at the left indicating conformance to this Directive.

China RoHS

Aruba products also comply with China environmental declaration requirements and are labeled with the “EFUP 10” label shown at the left.
www.arubanetworks.com.

Safety and Regulatory Compliance

Aruba Networks provides a multi-language document that contains country­specific restrictions and additional safety and regulatory information for all Aruba access points. This document can be viewed or downloaded from the following location:
www.arubanetworks.com/safety_addendum.
The device will be electronically labeled and the FCC ID will be displayed via the controller Web UI under the About menu.
RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems.

EMC Compliance and Warning Statement

IEC 60601-1-2: 2007 EN 60601-1-2: 2007
This equipment has been tested and found to comply with the limits of the standard for medical devices, IEC 60601-1-2:2007. The unit also complies with the requirements of EN 60601-1-2:2007, providing the presumption of compliance to the European Union’s Medical Device Directive 2007/47/EC. The limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in accordance with the manufacturer’s instructions may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes interference with other devices, which may be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:
Reorient or relocate the device receiving the interference.Increase the separation between the equipment.Connect the equipment into an outlet on a circuit different from that to which
the other device(s) are connected.
Consult the manufacturer or field service technician for help.
The Model IAP-105 does not have an Applied Part as defined in IEC 60601-1. The protection against electric shock is Class ll.
Device is not protected against ingress of liquids and has a protection class of IPX0 as defined by IEC 60601-1 and IEC 60529. Equipment not suitable for use in the presence of flammable mixtures.
The unit is considered “Continuous Operation” equipment as defined by IEC 60601-1.
Power Consumption – 48 VDC 802.3af power over Ethernet or 12VDC, 1.25A for external AC supplied power (adapter sold separately); Maximum power consumption – 12.5W.
Mechanical Dimensions: 132mm x 135mm x 45mm; 300g. Environmental: Operating Temp: 0° C to +50° C (+32° F to +122° F); Humidity: 5
to 95% non-condensing. Storage Temp: -40° CS to +70° C (-40°F to +158°F).
IAP-105 Wireless Access
Point
Installation Guide
Contacting Aruba Networks
Table 1
Contact Center Online
Main Site http://www.arubanetworks.com
Support Site https://support.arubanetworks.com
Wireless Security Incident Response Team (WSIRT)
EMEA Support Email emea.support@arubanetworks.com
WSIRT Email Please email details of any security problem found in an Aruba product.
Table 2
Service & Support Contact Center Telephone
Aruba Corporate +1 (408) 227-4500
FAX +1 (408) 227-4550
Support United States Universal Free Phone Service Number (UIFN): Australia, Canada,
China, France, Germany, Hong Kong, Ireland, Israel, Japan, Korea, Singapore, South Africa, Taiwan, and the UK
All Other Countries
Copyright
© 2011 Aruba Networks, Inc. AirWave®, Aruba Networks®, Aruba Mobility Management System®, Bluescanner, For Wireless That Works Wireless Workplace Is Now Open For Business, and The Mobile Edge Company Networks, Inc. All rights reserved. All other trademarks are the property of their respective owners.
®
, Mobile Edge Architecture, People Move. Networks Must Follow., RFProtect®, The All
Open Source Code
Certain Aruba products include Open Source software code developed by third parties, including software code subject to the GNU General Public License ("GPL"), GNU Lesser General Public License ("LGPL"), or other Open Source Licenses. The Open Source code used can be found at this site:
http://www.arubanetworks.com/open_source
Legal Notice
The use of Aruba Networks, Inc. switching platforms and software, by all individuals or corporations, to terminate other vendors' VPN client devices constitutes complete acceptance of liability by that individual or corporation for this action and indemnifies, in full, Aruba Networks, Inc. from any and all legal actions that might be taken against it with respect to infringement of copyright on behalf of those vendors.
Warranty
This hardware product is protected by the Aruba Limited Lifetime warranty. Altering this device (such as painting it) voids the warranty.
http://www.arubanetworks.com/support/wsirt.php
wsirt@arubanetworks.com
800-WI-FI-LAN (800-943-4526) +800-4WIFI-LAN (+800-49434-526)
+1 (408) 754-1200
®
are trademarks of Aruba
ENET (10/100/1000 Mbps)
11A/N Off 5 GHz radio is disabled
Green steady Power on, device ready
Off No link
Green on 1000 Mbps link
Amber on 10/100 Mbps link
Green flashing Ethernet link activity
Amber 5 GHz radio enabled in
WLAN mode
Green 5 GHz radio enabled in
11n mode
Green flashing 5 GHz Air Monitor or RF
Protect mode
www.arubanetworks.com 1344 Crossman Avenue Sunnyvale, California 94089 Phone: 408.227.4500
Fax 408.227.4550
IAP-105 Wireless Access Point | Installation Guide Part Number 0510860-03 | May 2011