Hestan KVC54TQ, KVC48TQ, KVC42GG, KVC36TQ, KVC30TQ Installation Manual

INDOOR COOKING
Vent Hood - Chimney
KVC
Installation, Use and Care Manual
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified installer or service agency.
DO NOT REPAIR, REPLACE OR REMOVE ANY PART OF THE APPLIANCE UNLESS SPECIFICALLY RECOMMENDED IN THE MANUAL. IMPROPER INSTALLATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL FOR GUIDANCE. ALL OTHER SERVICING SHOULD BE DONE BY A HESTAN AUTHORIZED SERVICE TECHNICIAN.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE INSTALLING OR USING YOUR APPLIANCE TO REDUCE THE RISK OF FIRE, BURN HAZARD, OR OTHER INJURY. KEEP THIS MANUAL FOR FUTURE REFERENCE.
SAFETY DEFINITIONS
THIS INDICATES THAT DEATH OR SERIOUS INJURY MAY OCCUR AS A RESULT OF NOT OBSERVING THIS WARNING
THIS INDICATES THAT MINOR OR MODERATE INJURY MAY OCCUR AS A RESULT OF NOT OBSERVING THIS WARNING.
THIS INDICATES THAT DAMAGE TO THE APPLIANCE OR PROPERTY MAY OCCUR AS A RESULT OF NOT OBSERVING THIS WARNING.
INSTALLER: LEAVE THIS MANUAL WITH THE OWNER OF THE APPLIANCE.
HOMEOWNER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
Message from Hestan:
Hestan’s award-winning culinary innovations and purpose-built features reinvented the restaurant kitchen and redefined culinary experience in some of America’s most acclaimed restaurants. Hestan now takes this performance from the back of the house and puts it front and center in yours. Thoughtfully designed and meticulously built, Hestan will serve you beautifully for years to come.
Hestan is the only residential brand born from the dreams and demands of professional chefs. From ranges to refrigeration, every detail is designed to deliver the performance and reliability expected in a restaurant – now available for you.
We appreciate you choosing Hestan, and we promise to deliver the very best to you.
Welcome to Hestan
EN
©2018 Hestan Commercial Corporation
3
EN
4
©2018 Hestan Commercial Corporation
TABLE OF CONTENTS
1 SAFETY PRECAUTIONS - BEFORE YOU BEGIN 4 MODEL NUMBERS 4 RATING LABEL 5 REGULATORY / CODE REQUIREMENTS 5 USING THE VENTILATION SYSTEM 6 CLEANING AND MAINTENANCE 9 TROUBLESHOOTING 10 DUCTING DO’S AND DON’TS 11 INSTALLATION 16 VENT ACCESSORIES 17 DUCT COVERS 19 PARTS / SERVICE 19 LIMITED WARRANTY
SAFETY PRECAUTIONS - BEFORE YOU BEGIN
EN
When properly cared for, your Hestan ventilation system will provide safe, reliable service for many years. When using this ventilation system, basic safety practices must be followed as described in the following pages.
IMPORTANT: Save these instructions for the local Utility Inspector’s use.
INSTALLER: Please leave these Installation Instructions with the owner.
OWNER: Please read these Instructions and save them for future reference
ELECTRICAL SHOCK HAZARD
It is the responsibility of the user to have the appliance connected by a licensed electrician in accordance with all applicable codes and standards, including fire-related construction. See “WIRING CONNECTION” on page16 for details.
ELECTRICAL SUPPLY AND GROUNDING
This appliance must be grounded. See “WIRING CONNECTION” on page16 for instructions.
This appliance must be connected to 120 VAC Single Phase, 60 Hz, with a current rating as shown in the model number listing on page4.
OWNER: Have the installer show you where the electric circuit breaker is located so you know how to shut off the power to this appliance.
Suitable for use in covered outdoor applications when installed in a GFCI protected branch circuit.
©2018 Hestan Commercial Corporation
1
SAFETY PRECAUTIONS - BEFORE YOU BEGIN
GENERAL SAFETY PRECAUTIONS
(CONT.)
EN
When properly cared for, your new Pro Canopy has been designed to be a safe, reliable ventilation system. Read all instructions carefully before using this ventilation system. When using kitchen appliances, basic safety precautions must be followed.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this ventilation system only as intended by the manufacturer. If you have any questions,
contact the manufacturer.
b) Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette,
Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on blower or
filter
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner.
BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dish cloths or towels - a violent steam explosion will result.
d) Use an extinguisher ONLY IF:
1. You know you have a Class ABC fire extinguisher and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
1
2
4. You can fight the fire with your back to an exit.
1 Based on “Kitchen Firesafety Tips” published by NFPA.
©2018 Hestan Commercial Corporation
SAFETY PRECAUTIONS - BEFORE YOU BEGIN
(CONT.)
BURN HAZARD
This ventilation system is intended for use with ranges or cooktops, which can get very hot during operation. Observe the warnings and cautions for the cooking appliance.
This ventilation system should be serviced only by a Hestan authorized service technician. Contact the nearest authorized service center for examination, repair or adjustment.
Do not repair or replace any part of the system unless specifically recommended. Refer service to an authorized servicer.
Do not operate this ventilation system if it is not working properly or if it has been damaged, until an authorized servicer has examined it.
Install or locate this ventilation system only in accordance with the Installation section of this manual. Do not cover or block any openings on this ventilation system.
It is highly recommended that a suitable kitchen fire extinguisher (Class ABC or K) be readily available and highly visible next to any cooking appliance.
SAFETY DURING CLEANING
Clean only ventilation system parts listed in this manual, in the manner specified in this manual.
Note: the “ventilating fans” and “filter” in the previous warnings refer to the blower wheel(s), blower housing(s), and blower shield(s).
EN
THIS MANUAL SHOULD REMAIN WITH THE HOMEOWNER FOR FUTURE REFERENCE.
©2018 Hestan Commercial Corporation
3
MODEL NUMBERS
MODEL NO. DESCRIPTION BLOWER PACKAGE
EN
KVC 30
KVC 36
KVC 42
KVC 48
KVC 54
30” Chimney-style 600 cfm Kitchen Ventilation System WM2L Dual
36” Chimney-style 600 cfm Kitchen Ventilation System WM2L Dual
42” Chimney-style 900 cfm Kitchen Ventilation System WM2L Dual + WM1L Single
48” Chimney-style 900 cfm Kitchen Ventilation System WM2L Dual + WM1L Single
54” Chimney-style 1200 cfm Kitchen Ventilation System Two WM2L Duals
RATINGS
Blower
Package
Amps
CFM
SP@0.0”
Equivalent
CFM *
CFM
SP@0.1”
CFM
SP@0.2”
CFM
SP@0.3”
WM2L Dual 2.9 600 900 531 480 430 8” (50 in.
WM2L Dual +
4.4 900 1350 804 725 655 AKVT6810:
WM1L Single
Two WM2L
5.8 1200 1800 1062 960 860 AKVT8812:
Duals
Minimum
Round Duct
Size
2
10” (79 in.
12” (113 in.
) 6.5
2
)
2
)
All units 115 VAC 60 Hz 1550 RPM
* When comparing the Hestan system with blower units made by other manufacturers, use the “Equivalent CFM”.
Sones **
6.3
6.6
** Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering
Experiment Station.
RATING LABEL
The rating label contains important information about your Hestan appliance such as the model and serial number, electrical rating and the minimum installation clearances.
The rating label is located on the underside of the blower housing.
If service is necessary, contact Hestan Customer Care with the model and serial number information shown on the label.
HESTAN COMMERCIAL CORP.
ANAHEIM, CA - USA
MODEL WM2L
TYPICAL RATING LABEL
Rating label location
4
©2018 Hestan Commercial Corporation
REGULATORY / CODE REQUIREMENTS
Installation of this ventilation system must be made in accordance with local codes. In the absence of local codes, this unit should be installed in accordance with the National Electrical Code and local codes.
This appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code
C22.1
.
ANSI/NFPA 70
, or Canadian Electrical code
CSA
USING THE VENTILATION SYSTEM
FEATURES OF THE VENTILATION SYSTEM
Speed controls are provided for each blower assembly. Two-blower systems will have one speed control knob, while three- or four-blower systems will have two speed control knobs. A control knob is provided for lighting intensity.
The controls layout will be similar to that shown below.
USING THE HOOD
The user can start with the a hood on the lowest setting, and then increase speed and/or turn on additional blowers as required. Using the hood at high settings may increase heating or air conditioning requirements and costs for the house.
EN
BLOWER CONTROL KNOB
To operate the blower(s), rotate the knob through the blower speed settings by turning it clockwise (facing the knob).
Rotate the knob counter-clockwise to reduce the blower speed.
LIGHT CONTROL KNOB
To operate the lights, rotate the knob through the light intensity settings by turning it clockwise (facing the knob). Rotate the knob counter-clockwise to dim the lights or turn them off.
Controls for two blowers
Item
Function
Blower control
1
Light control
2
Blower control
3
blowers 1 & 2
Blower control,
4
blower 3 or blowers 3 & 4
1
Controls for three and four blowers
3
2
2
4
©2018 Hestan Commercial Corporation
5
CLEANING AND MAINTENANCE
CLEANING THE VENTILATION SYSTEM
EN
Cleaning requirements depend completely on usage and environment. The more high-heat and/or greasy cooking, the more often the hood and blower will need cleaning.
The grease tray and blower aren’t visible from the outside, so they must be removed for inspection.
After you’ve inspected the tray a few times over the course of six months or a year, you’ll be able to set a cleaning schedule according to your usage pattern.
HOOD CANOPY
Wipe down the interior and exterior of the hood as needed with a soft cloth and warm soapy water (liquid dish detergent is acceptable). Do not use acids, abrasives, strong detergents, solvents, or scouring pads. Stainless steel should be treated with a quality stainless steel cleaner such as Stainless Steel Magic®. Follow all label instructions. Do not polish across the grain or in circles.
BLOWER HOUSING AND SHIELD
To reduce the risk of personal injury, be sure the power is turned off in the hood before removing the shield(s) and blower housing(s).
The blower captures grease by-products in the blower housing(s) and blower shield(s). The blower shields require more frequent cleaning than the blower housing but cooking usage determines how often each item will need to be cleaned.
Item
Description
Blower housing
1
Blower shield
2
1
2
6
BLOWER SHIELD
The blower shields are easily removed for cleaning by pulling the blower shield(s) toward the front of the hood.
Be careful to keep the tray level if the hood has been recently used and the grease might still be warm.
Inspect and clean the shield. (Details follow)
BLOWER HOUSING
To remove the blower housing:
1. Unsnap two suitcase latches, one on each side of the housing.
2. Support the housing and pull it away from the blower base.
3. While pulling it back, gently “tip” it downward to clear the blower wheel(s).
©2018 Hestan Commercial Corporation
2
CLEANING AND MAINTENANCE
CLEANING
Clean the shield(s) and/or blower housing(s) in a sink of warm soapy water (liquid dish detergent) and let soak for a few minutes. Wash with a sponge or dishcloth, rinse and let drain before reinstalling. Alternatively, the blower housing(s) and blower shield(s) may be placed into a dishwasher.
(CONT.)
2
3
4
1
EN
Item #
To reduce the risk of personal injury, be sure the power is turned off in the hood before removing the shield(s) and blower housing(s).
Regular cleaning of the blower housing should prevent grease accumulation on the blower wheel. If grease build-up should occur, the blower wheel may easily be cleaned in place using a soft bristle toothbrush and a common degreaser such as Formula 409®.
Take care not to move or lose the metal balancing clips that may be affixed to the wheel.
Item #
Description
Motor housing
1
Wheel
2
Blower housing
3
Blower shield
4
Description
Balancing clip
1
Blower wheel
2
1
©2018 Hestan Commercial Corporation
7
EN
CLEANING AND MAINTENANCE
BLOWER WHEEL REMOVAL
For instances where the blower wheel must be removed, follow the instructions below.
Removing the blower wheel requires a 1/8” hex wrench. This may be obtained from your local hardware store or tool supply.
The wheel is retained by a set screw on the side of the hub of the wheel (1) that tightens up against a “flat” spot on the motor shaft. (See illustration on previous page.)
1. Locate the set screw on the side of the hub of the wheel
2. Insert wrench through the blades of the blower wheel and into the set screw.
3. Loosen the set screw 1/2 turn counterclockwise.
(CONT.)
If the wheel is difficult to remove, the area where the motor shaft makes contact with the blower wheel hub may need to be sprayed with a common penetrating oil such as WD-40
After allowing the penetrating oil to soak for a few minutes, push the blower wheel forward slightly, then gently pull the blower wheel off the motor shaft.
Use caution to avoid bending or distorting the blower wheel and take care not to move or lose the metal balancing clips (2) that may be affixed to the wheel (1).
A soft bristle toothbrush with warm soapy water may be used to clean the blades, or soak the blower wheel in warm soapy water.
BLOWER WHEEL INSTALLATION
When reinstalling the wheel onto the motor shaft, make sure the set screw makes direct contact with the “flat spot” on the motor shaft.
1. Slide the blower wheel onto the motor shaft as far as it will go, making sure the back of the blower wheel does not touch the motor mount screws protruding from the motor.
If the motor is too far back, it will rub the motor mount screws, and if it is too far forward, it will rub the inside of the blower housing.
2. Adjust the blower wheel slightly to find the correct front-to-rear location.
3. Tighten the set screw (clockwise) to lock the blower wheel in the correct position.
For hoods that have more than one blower wheel, make sure that white blower wheels are matched up with white motor rings, and black blower wheels are matched up with black motor rings.
@
.
8
The hood will not perform properly if blower wheels and motors are mismatched.
MOTOR REPLACEMENT
To reduce the risk of personal injury, turn off power to the hood at the breaker or the circuit disconnect before attempting to remove the blower motor.
MOTOR IDENTIFICATION AND POSITIONING
Motors are color-coded; black and white motors have different rotations and must be installed in the correct positions.
Housings with a single blower use a white blower and wheel.
Housings with two blowers use a white blower on the right and black on the left.
©2018 Hestan Commercial Corporation
CLEANING AND MAINTENANCE
Make sure you have the correct motor in each housing position.
If the replacement blower motor includes a blower wheel, then you can remove the motor and wheel together. If you will re-use your existing wheel, then you may wish to remove the wheel before removing the motor.
1. Remove the shield and blower housing as described in “Blower Wheel Removal” on page 8.
2. Use a ¼” nut driver to remove the three motor mount screws that attach the motor to the hood.
3. Gently pull the motor forward and down.
4. Disconnect the wiring harness, remove the old motor.
To avoid damage to the blower wheel, you may wish to install the motor and then install the wheel onto the motor.
5. Lift the new motor so you can connect the wiring harness. Be sure to fully engage the electrical connections and tighten the motor mount screws.
6. Check the blower wheel clearance and adjust as needed, as described in “Blower Wheel Installation” on page 8.
(CONT.)
EN
TROUBLESHOOTING
If the hood does not perform satisfactorily, check the following:
Do the blowers run?
Are the blower wheels installed on the correct motors? (black wheel on black motor, white wheel on white motor)
Are the motor and wheel assemblies installed in the correct locations?
Check the damper doors in hood behind/above blowers - do they move/open freely?.
Check the dampers/vents to outside - do they open freely, with no obstructions?
Check for damaged or obstructed ductwork.
©2018 Hestan Commercial Corporation
9
DUCTING DO’S AND DON’TS
of Two Ducts
GENERAL REQUIREMENTS
EN
Observe local codes regarding special duct requirements and placement of duct work against combustibles.
Using recommended transitions (see VENT ACCESSORIES) will ensure proper efficiency.
Using recommended roof caps or wall louvers (see VENT ACCESSORIES) will ensure proper efficiency.
Use foil HVAC tape (not grey cloth duct tape) to seal all joints.
The hood must be ducted to the outdoors without restrictions.
BLOWER REQUIREMENTS
The single blower unit (WM1L, used in 900 CFM systems) requires 6” round duct or equivalent (28 square inches), and the dual blower unit (WM2L, used in all systems) requires 8” round duct or equivalent (50 square inches).
COMBINED DUCT SIZE AFTER A TRANSITION
Single and Dual (WM1L & WM2L) combine to 10” round or equivalent 79 sq. in. using a multi­blower transition such as AKVT6810 (Optional).
Two Duals (Two WM2Ls) combine to 12” round or equivalent 113 sq. in. using a multi-blower transition such as AKVT8812 (Optional).
DUCTING REQUIREMENTS
NEVER reduce the duct size. When combining ducts together, the square inch area of the outlet duct must be equal or greater than the total square inch area of the ducts being combined.
Only use smooth, galvanized, metal duct. Do not use flexible or corrugated duct. This type of duct will restrict airflow and reduce performance.
Make the duct run as short and as straight as possible with as few turns as possible.
Avoid sharp-angled turns. Instead, use smooth, gradual turns such as adjustable elbows or 45 degree angled turns.
For duct runs over 20 feet, increase the duct diameter by one inch for every ten feet of duct.
When planning length, a 90 degree elbow is equivalent to 5 feet of duct.
10
TERMINATION REQUIREMENTS
Airflow must not be restricted at the end of the duct run.
A wall louver or roof cap is required for each duct run.
Every wall louver or roof cap must include a gravity damper to prevent back drafts.
Do not use screen wire or spring-loaded doors on wall louvers or roof caps.
YES
Do not terminate venting into an attic or chimney.
©2018 Hestan Commercial Corporation
Smooth Duct
NO
Flexible Duct
Smooth Gradual Turn
Sharp Angled Turns
Proper Combining
of Two Ducts
Improper Combining
INSTALLATION
WM2L Dual Blower (600 CFM ) (Top View)
Connection diagram (30-36” width)
INSTALLATION DETAILS
1. Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only. Custom hoods may require additional consideration.
See “DUCTING DO’S AND DON’TS” on page10
Weight and size: For safe installation, at least two people should be present to lift and hold the hood. For larger hoods and installations with tall duct covers, it is advisable to have a third person present to assist.
Back Venting: If venting out the wall behind the hood instead of venting through the ceiling, see “Back Venting” on page 15 for particulars.
2. When installing a wall mount range hood, it is recommended that the bottom edge of the hood be located no more than 30” above the cooking surface for optimum performance.
3. IF THE HOOD IS TO BE “BACK VENTED”, PROCEED DIRECTLY TO STEP 4.
Optional duct
cover
18”
Consult the connection diagrams (following) for further details on exhaust outlet placement.
Install the duct(s) from the outside of the home down to the location
of the exhaust outlet(s) on the top of the hood allowing room for
30”
the transition (if applicable). If a transition is used, install duct down to the location of the transition outlet plus 1”. This will allow the transition to engage 1” inside of duct.
Use foil HVAC tape (not gray cloth duct tape) to seal all joints. See
“Vent Accessories” on page 16 for complete listing of available ducting materials.
36”
EN
TRANSITION HEIGHTS:
Dual Blower (WM2L, 600 CFM): no transition - 8” round duct will
connect directly to the top of the hood.
Single and Dual Blower (WM1L + WM2L, 900 CFM): 10” round duct connects to the included
AKVT6810 transition, 8 1/2” above top of hood.
Two Dual Blowers (Two WM2Ls, 1200 CFM):
12” round duct connects to the included AKVT8812 transition, 7 1/2” above top of hood.
CONNECTION DIAGRAMS
5 1/2"
Wall side
1 3/4" [4.4 cm]
Electrical
8" [20.3 cm] round
Motor
Cooling
Vent
[14 cm]
5 1/4" [13.3 cm]
Centerline of hood
©2018 Hestan Commercial Corporation
11
Installed (Front View)
EN
INSTALLATION
(CONT.)
12 ⁄
[32.7 cm]
9 ⁄
[23.2 cm]
Wall Side
18"
[45.7 cm]
1 ¾”
[4.4 cm]
10" Outlet
centered on
hood top
900 CFM WM2L Dual + WM1L Single Blower (Top View)
Connection diagram (42”, 48” widths)
10"
[25.5 cm]
AKVT6810 Standard Transition
Electrical (2)
Centerline
of hood
Duct cover
(Top of Hood)
10" Dia. or 12" Dia.
Transition location
"Centered"
For 900 and 1200 CFM hoods, the transition (AKVT6810 or AKVT8812) is installed in the hood at the factory as a standard item. It will be located in the exact center of the duct cover (left to right & front to rear).
12
1 3/4" [4.4 cm]
12" outlet
centered on
top of hood
©2018 Hestan Commercial Corporation
16 ½”
[41.9 cm]
7"
[17.8 cm]
1200 CFM Two WM2L Dual Blowers
5 1/2"
[14 cm]
Connection Diagram (54” Width)
1 3/4" [4.4 cm]
wall side
electrical (2)
centerline
of hood
(Top View)