Hestan KMWR30 Installation Manual

INDOOR COOKING
Drawer Microwave
KMWR30
Installation Manual
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified installer or service agency.
DO NOT REPAIR, REPLACE OR REMOVE ANY PART OF THE APPLIANCE UNLESS SPECIFICALLY RECOMMENDED IN THE MANUAL. IMPROPER INSTALLATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL FOR GUIDANCE. ALL OTHER SERVICING SHOULD BE DONE BY A HESTAN AUTHORIZED SERVICE TECHNICIAN.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE INSTALLING OR USING YOUR APPLIANCE TO REDUCE THE RISK OF FIRE, BURN HAZARD, OR OTHER INJURY. KEEP THIS MANUAL FOR FUTURE REFERENCE.
SAFETY DEFINITIONS
THIS INDICATES THAT DEATH OR SERIOUS INJURY MAY OCCUR AS A RESULT OF NOT OBSERVING THIS WARNING
THIS INDICATES THAT MINOR OR MODERATE INJURY MAY OCCUR AS A RESULT OF NOT OBSERVING THIS WARNING.
THIS INDICATES THAT DAMAGE TO THE APPLIANCE OR PROPERTY MAY OCCUR AS A RESULT OF NOT OBSERVING THIS WARNING.
INSTALLER: LEAVE THIS MANUAL WITH THE OWNER OF THE APPLIANCE.
HOMEOWNER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
TABLE OF CONTENTS
1 SAFETY PRECAUTIONS - BEFORE YOU BEGIN 2 MODEL NUMBERS 2 RATING LABEL 2 REGULATORY / CODE REQUIREMENTS 2 IMPORTANT NOTES 3 CLEARANCES AND DIMENSIONS 10 INSTALLATION STEPS
SAFETY PRECAUTIONS - BEFORE YOU BEGIN
When properly cared for, your Hestan Drawer Microwave will provide safe, reliable service for many years. When using this microwave, basic safety practices must be followed as described in the following pages.
IMPORTANT: Save these instructions for the local Utility Inspector’s use.
INSTALLER: Please leave these Installation Instructions with the owner.
OWNER: Please read these Instructions and save them for future reference
EN
ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing appliance. Failure to do so can result in electrical shock or death. It is the responsibility of the user to have the appliance connected by a licensed electrician in accordance with all applicable codes and standards, including fire-related construction. See "ELECTRICAL CONNECTION" for details.
ELECTRICAL SUPPLY AND GROUNDING
This appliance must be grounded. Grounding reduces the risk of electric shock in the event of a short circuit. See "INSTALLATION STEPS" on page10 for instructions.
This appliance must be connected to 120 VAC Single Phase, 60 Hz, with a current rating as shown in the model number listing on page2.
OWNER: Have the installer show you where the electric circuit breaker is located so you know how to shut off the power to this appliance.
GENERAL SAFETY PRECAUTIONS
When properly cared for, your new Drawer Microwave has been designed to be a safe, reliable appliance. Read all instructions carefully before using it. When using kitchen appliances, basic safety precautions must be followed.
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a) Use this microwave only as intended by the manufacturer. If you have any questions, contact
the manufacturer.
b) Before servicing or cleaning unit, unplug the microwave or switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on accidentally. If the appliance cannot be unplugged and the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
©2019 Hestan Commercial Corporation
1
MODEL NUMBERS
Anaheim, CA 92806
Sealing
W
Sealing
Sealing surface
Oven cavity
MODEL NO. DESCRIPTION CIRCUIT BREAKER
EN
KMWR30
30” Drawer Microwave 15 Amps
All units 115 VAC 60 Hz
RATING LABEL
The rating plate includes model and serial number. Open the Drawer Microwave fully. The label is beyond the back wall of the drawer facing up from the bottom surface.
If service is necessary, contact Hestan Customer Care with the model and serial number information shown on the label.
Hestan Commercial Corporation 3375 E. La Palma Ave
TYPICAL RATING LABEL
REGULATORY / CODE REQUIREMENTS
Installation of this cooking appliance must be made in accordance with local codes. In the absence of local codes, this unit should be installed in accordance with the National Electrical Code and local codes.
This appliance must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI/NFPA 70, or Canadian Electrical code CSA C22.1.
IMPORTANT NOTES
UNPACKING YOUR DRAWER MICROWAVE
Remove all packing materials from inside the Drawer Microwave. DO NOT REMOVE THE WAVEGUIDE COVER, which is located on the top of the Drawer Microwave.
Remove the feature sticker, if there is one. Check the drawer for any damage, such as misaligned or bent drawer, damaged drawer seals and sealing surfaces, broken or loose Drawer Microwave guides and dents inside the cavity or on the front side of the drawer. If there is any damage, do not operate the Drawer Microwave and contact your dealer or a HESTAN AUTHORIZED SERVICER.
IMPORTANT NOTES TO THE INSTALLER
Read all of the Installation Manual before installing the Drawer Microwave.
Remove all packing material before connecting the electrical supply.
Observe all governing codes and ordinances.
BE SURE TO LEAVE THESE INSTRUCTIONS WITH THE CONSUMER.
surface
aveguide
cover
surface
Oven cavity
2
©2019 Hestan Commercial Corporation
CLEARANCES AND DIMENSIONS
IMPORTANT NOTES TO THE CONSUMER
Keep this manual with your Use and Care Manual for future reference.
As when using any microwave oven generating heat, there are certain safety precautions you should follow. These are listed in the Use and Care Manual. Read all and follow carefully.
Be sure your Drawer Microwave is installed and grounded properly, in accordance with local codes by a qualified installer or service technician.
IMPORTANT SAFETY INSTRUCTIONS
If the information in this manual is not followed exactly, a fire or electrical shock may result that could cause property damage, personal injury or death.
To reduce the risk of tipping, the Drawer Microwave must be secured by a properly installed Anti-Tip block.
Do not install drawer in any combustible cabinetry unless it meets the stated clearances and dimensions on the following pages. See Figure 1, 2 and 3.
Make sure the wall coverings and the cabinets around the Drawer Microwave can withstand the heat generated by the appliance.
Never leave children alone or unattended in the area where a Drawer Microwave is in use. Never leave the drawer open when the microwave is unattended.
Stepping, leaning or sitting on the drawer may result in serious injuries and can also cause damage to the Drawer Microwave.
Do not use the Drawer Microwave as a storage space. This creates a potentially hazardous situation.
Check that the time of day is in the display. If not, touch Stop/Clear to prevent unintended use.
EN
ABOUT DIMENSIONS
Figure 1 shows dimensions of the unit. Figures 2 - 3 provide minimum clearance for standard (non-flush) installation. Figures 4 - 9 show clearances and additional information for flush installation. Suggested electrical outlet location is shown in figures 2 - 6.
Contact surface must be solid and level. Pay special attention to the floor on which the Drawer Microwave will sit. The floor of the opening should be constructed of plywood strong enough to support the weight of the unit–about 100 pounds [45 kg].
Check location where the Drawer Microwave will be installed for proper electrical supply.
Your Drawer Microwave can be installed into a cabinet by itself or below any electric or gas wall oven. Be sure that the clearance of the floor between the wall oven and the Drawer Microwave is a minimum of 2 inches [5.1 cm].
Always check electrical codes for requirements.
The Drawer Microwave must be placed close enough to the electrical outlet so that the cord is not under tension.
See Figures 1 - 6 for required clearances and dimensions when planning the drawer’s location.
1 An electrical outlet in an adjacent cabinet can be used, as long as the provided electrical cord can reach without pulling tight. Power cord access hole in cabinet should be a minimum 1 1/2" [3.8 cm] diameter hole and deburred of all sharp edges.
1
©2019 Hestan Commercial Corporation
3
CLEARANCES AND DIMENSIONS
DRAWER MICROWAVE DIMENSIONS
(CONT.)
EN
I
G
F
D
Figure 1. Microwave dimensions
H
power cord
A
D
K
B
E
KEY DESCRIPTION DIMENSION
A Unit width 21-5/8 in. [54.9 cm] B Depth w/out door 21-7/8 in. [55.6 cm] C Height of body 14-19/32 in. [37.1 cm]
D Width of door face 30 in. [76.2 cm] E Door thickness 1-11/16 in. [4.3 cm] F Height of door face 15 in. [38.1 cm] G Cord recess depth 4 in. [10.2 cm]
H Cord recess width 4-11/16 in. [11.9 cm]
I Cord recess height 1-3/4 in. [4.5 cm]
K Auto drawer opening 15 in. [38.1 cm]
4
©2019 Hestan Commercial Corporation
CLEARANCES AND DIMENSIONS
(CONT.)
CABINET DIMENSIONS, STANDARD INSTALLATION
84 in.
[213.4 cm]
wall
cabinet
Suggested
electrical
outlet location*
5 in.
[12.7 cm]
6 in.
[15.2 cm]
EN
Optional wall oven cutout illustrated in sketch
Anti-Tip block
3 1/2 in. [8.9 cm]
H
E
G
C
Floor must support 100 lbs. [45 kg]
D
4 in.
B
[10.2 cm]
D
A
F
19 in. [48.3 cm] to
top of floor
(recommended)
30" [76.2 cm]
cabinet min.
Figure 2. Standard mounting under oven
KEY DESCRIPTION DIMENSION
A Cutout width 28-7/16 in. [72.2 cm] B Cutout depth 23-1/2 in. [59.7 cm] C Height of opening 14-13/16 in. [37.6 cm] D Sides overlap 3/4 in. [1.9 cm] E Top edge overlap 3/16 in. [0.5 cm]
F Bottom edge overlap 7/16 in. [1.1 cm]
G Bottom of opening to bottom of anti-tip block 14-13/16 in. [37.6 cm]
©2019 Hestan Commercial Corporation
5
CLEARANCES AND DIMENSIONS
Suggested electrical
Parts included:
(CONT.)
EN
outlet location*
36 in.
[91.4 cm]
countertop
height
A
D
30 in. [76.2 cm]
cabinet min.
B
[12.7 cm]
4 in.
[10.2 cm]
5 in.
D
E
C
F
19 in. [48.3 cm] to
top of floor
(recommended)
6 in. [15.2 cm]
Anti-Tip block
3 1/2 in. [8.9 cm]
G
Floor must support
100 lbs. [45 kg]
Figure 3. Standard mounting under counter
FLUSH INSTALLATION
If installing flush to the cabinet, the provided deflector vent must be installed. Observe the following cabinet dimensions.
FLUSH MOUNT DEFLECTOR VENT PARTS
Part numberQty.
Flush Mount
1
Deflector Vent
2
Mounting screws
6
©2019 Hestan Commercial Corporation
CLEARANCES AND DIMENSIONS
A
I
CABINET DIMENSIONS
(CONT.)
B
C
D
G
L
F
K
J
M
E
H
N
Note: the face of the shelf
must sit 1
from the face of the cabinet.
shelf face
3
/4" [44.45 mm] back
O
cabinet face
EN
Figure 4. Mounting flush under counter
Key Dimension
A.
6" [152.40 mm]
B.
Suggested electrical outlet location
C.
Anti-Tip block
D.
5" [127 mm]
E.
3-1/2" [88.90 mm]
F.
4" [101.60 mm]
G.
30-5/16" [769.92 mm] minimum 30-5/8" [777.87 mm] maximum
H.
14-13/16" [376.24 mm] to bottom of Anti-Tip block
I.
1-1/16" [26.97 mm]
J.
23-1/2" [596.90 mm] minimum depth
K.
28-7/16" [722.3 mm]
L.
1-3/4" [44.45 mm]
M.
16-7/8" [428.62 mm] opening
N
Floor must support 100 lb [45.4 kg]
O
1-3/4" [44.45 mm]
©2019 Hestan Commercial Corporation
7
Loading...
+ 19 hidden pages