Hestan AGPB24NGTQ Specifications

STANDARD FEATURES
• High-performance 321SS tubular outer burner at 50,000 BTU/hour
• 20,000 BTU/hour brass inner burner with simmer capability
• Electronic spark ignition system with re-ignition capability
• Commercial-grade 1/2" diameter stainless steel rod grate with 1/4" thick DiamondCut Grate™ center that is removable for wok cooking
POWER BURNER
Grate
Wok Compatible
Bright LED Lighting
• Accommodates 14"-20" diameter woks
• Sealed burner bowl with drain
• Stainless steel removable drip tray for ease of cleaning
• Marquise™ accented control panel
• LED front control panel lighting with simple touch on function
• Heavy gauge welded body construction
• Patented Zamak die-cast knobs, burner indicators and bezels
• Stainless steel top cover
Stainless Cover Power Burner
Model number as shown AGPB24
OPTIONS & ACCESSORIES
• Natural Gas (NG) or Liquid Propane (LP)
• Twelve (12) Hestan signature color nishes
• Carbon Fiber Vinyl Cover
• Gas conversion kits (NG/LP)
POWER BURNER
www.hestanoutdoor.com phone 888.905.7463
3375 E. La Palma Ave., Anaheim, CA 92806
POWER BURNER
* MIN. VERT. CLEARANCE TO
COMBUSTIBLE CONSTRUCTION (SEE MANUAL PG. 9)
9.00
18.8
47.8
*
9.00
LAYOUT FOR
3 X 5 [7.6 X 12.7]
OPENING FOR
GAS SUPPLY
& ELECTRICAL
1.00
6.25
*
D
1.00
2.5
MAX.
COUNTERTOP
OVERHANG
TOP VIEW
.44
1.1
NOTCH
H
36.0
91.4
REF.
W
NON-COMBUSTIBLE
ENCLOSURE (ISLAND)
POWER
BURNER
AGPB24
ACCESS DOOR
(SOLD SEPARATELY)
W D H
(in) (cm)(in) (cm) (in) (cm)
23.25 59.1 22.50 57.2 11.13 28.3
DIMENSIONS IN [ ] ARE IN CM.
TYPICAL ISLAND
COUNTERTOP INSTALLATION
2.50
6.4
MIN.
OPENING FOR
ACCESS DOOR
All Models Description Total Btu’s
W(in.) D(in.) H(in.)
AGPB24-NG / -LP Power Burner, Built-in, 24”
Cutout Dimensions
23-⁄
10 in² [64.5 cm²] MIN. VENTILATION
OPENING ON
BOTH SIDES
AND REAR
22-⁄ 11-⁄
70,000
www.hestanoutdoor.com phone 888.905.7463
ELECTRICAL REQUIREMENTS
:
120V, 60Hz, 1 amp
GAS REQUIREMENTS : ⁄” NPT gas connection. Minimum gas supply
is 7” water column for natural gas and 11” for propane. Operating pressure at the manifold is 4” water column for natural gas and 10” for propane. All units require a regulated gas supply. (included)
Hestan Outdoor products are approved for outdoor use only. Hestan Commercial Corporation reserves the right to change materials and specications without notice. Specify type of gas when ordering.
3375 E. La Palma Ave., Anaheim, CA 92806CONTACT US:
011033 REV C