Hestan AGB122LPTQ, AGB121LPTQ Maintance Manual

OUTDOOR COOKING
Outdoor Side Burner
AGB
Use & Care Manual
Installation & Operation
HESTAN OUTDOOR, MOST POWERFUL, VERSATILE AND RELIABLE OUTDOOR COOKING AVAILABLE.
Message from Hestan:
Outdoor cooking is a perfectionist’s pursuit, and with your new investment, you’ve now taken the ultimate step forward. We sincerely welcome you to the Hestan Family. We’ve engineered and built our products so that your guests will rave about your meal, but deep down, our customers know it could’ve been just a little more tender, juicier – a pinch more salt in the rub or a few seconds less on the flame. Yes, we’ve taken the time to know our Hestan customer and we’re excited to be on this journey with you. Hestan Outdoor was born from this same perfectionist passion. Our engineers experimented, innovated, tweaked and tinkered until they created the most powerful, versatile and reliable outdoor products available.
We pride ourselves on restless innovation, superior engineering and
EN
purpose-built designs, but also our in-depth understanding of our target consumer and the interests and needs of the ultimate end-users we serve and covet. For many consumers, cooking outdoors is much more than an act of food preparation. It’s a lifestyle activity that encompasses culinary, leisure and social pursuits among others.
We are thankful and proud that you have chosen Hestan, and we yearn to have you as a customer for life. We take your decision to choose Hestan most seriously, and we promise to deliver the very best to you.
Welcome to Hestan Outdoor
©2018 Hestan Commercial Corporation
1
EN
DANGER
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the appliance and immediately call your gas supplier or your fire department.
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not try lighting this appliance without reading the LIGHTING INSTRUCTIONS section of this manual.
For outdoor use ONLY. This cooking appliance is not intended to be installed in or on recreational vehicles, and/or boats.
1. Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
Flammable Gas - disconnect all propane or natural gas supplies to this unit before servicing.
Electrical Parts & Components – disconnect all power supplies and batteries before servicing.
READ THIS MANUAL CAREFULLY AND COMPLETELY BEFORE USING YOUR SIDE BURNER TO REDUCE THE RISK OF FIRE, BURN HAZARD, OR OTHER INJURY. KEEP THIS MANUAL FOR FUTURE REFERENCE.
2
©2018 Hestan Commercial Corporation
TABLE OF CONTENTS
4 MODEL NUMBERS
5 RATING LABELS
5 PRECAUTIONS
8 REGULATORY / CODE REQUIREMENTS
8 PORTABLE LP CYLINDERS
9 LOCATION AND ASSEMBLY
9 INSTALLATION
13 GAS AND ELECTRICAL CONNECTIONS
21 LIGHTING INSTRUCTIONS
23 USING YOUR SIDE BURNER
23 CLEANING AND MAINTENANCE
26 TROUBLESHOOTING
EN
27 WIRING SCHEMATICS
31 PARTS LIST
31 SERVICE
31 WARRANTY
©2018 Hestan Commercial Corporation
3
EN
MODEL NUMBERS
AGB121
BUILT-IN MODELS
Model No. Description
AGB121-NG / -LP 12” BUILT-IN SINGLE SIDE BURNER
AGB122-NG / -LP 12” BUILT-IN DOUBLE SIDE BURNER
AGB122
4
©2018 Hestan Commercial Corporation
RATING LABEL
The rating label contains important information about your Hestan appliance such as the model and serial number, gas type and manifold pressure, the BTU rating for each burner type, and the minimum installation clearances.
Hestan Outdoor Side Burner rating label is located on the inside rear wall of the unit, behind the control panel.
PRECAUTIONS - BEFORE YOU USE YOUR SIDE BURNER
When properly cared for, your Hestan Side Burner will provide safe, reliable service for many years. However, extreme care must be used since the Side Burner produces intense heat, which can cause serious injury or even death if the instructions are not followed carefully. When using this appliance, basic safety practices must be followed as outlined below.
EN
1. NEVER LEAVE THE SIDE BURNER UNATTENDED WHILE COOKING.
2. Children should not be left alone or unattended in an area where the Side Burner is being used. Never allow them to sit, stand, or play on or around the Side Burner. Do not store items of interest to children around or below the Side Burner or in the cart. Never allow children to crawl inside of the cart.
3. Never operate the Side Burner while under the influence of alcohol or drugs.
4. Never use the Side Burner in windy conditions. If located in a consistently windy area, oceanfront, mountaintop, etc., a windbreak will be required. Always adhere to the specified clearances as described in the INSTALLATION section of this manual.
5. The Side Burner shall be used only outdoors and shall not be used in buildings, garages, sheds, breezeways, or any enclosed areas. Do not operate the Side Burner under unprotected, combustible construction. Use only in well-ventilated areas. See the INSTALLATION section of this manual.
6. Do not use the Side Burner unless a leak check has been performed on all gas connections. See the GAS CONNECTIONS section of this manual.
7. If the Side Burner is installed by a professional installer or technician, be sure that they show you where your gas supply shut-off is located. All gas lines must have a shut-off that is easily accessible. If you smell gas, check for leaks immediately. Check only with a soap and water solution. Never check gas leaks with an open flame. See the GAS CONNECTIONS section of this manual.
©2018 Hestan Commercial Corporation
5
PRECAUTIONS - BEFORE YOU USE YOUR SIDE BURNER
8. Check the regulator, hoses, burner ports, and venturi / valve section carefully. Always turn
off gas at the source (tank or supply line) prior to inspecting parts.
(continued)
EN
9. When lighting a burner, always pay close attention to what you are doing. Be certain you
are turning the correct knob labeled for the burner you intend to use. If any burner does not light, or goes out during operation, turn off all gas control knobs, and wait five (5) minutes before attempting to re-light. See the LIGHTING INSTRUCTIONS section of this manual.
10. Portable LP cylinders - Always shut off the main valve on the liquid propane (LP) cylinder
after each use. Never use a dented or rusted LP cylinder. Never attach or disconnect an LP cylinder, or move or alter gas fittings when the Side Burner is in operation or is hot.
11. Inspect LP gas supply hose prior to each use of the Side Burner. The hose must be kept away
from heated areas of the Side Burner. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced before using the Side Burner. The hose and LP regulator are supplied as a complete assembly and must be replaced together. Do not attempt to repair or replace the hose itself. Contact your Hestan dealer for genuine replacement P/N 014309.
12. Keep any electrical supply cord away from the heated areas of the Side Burner. The cord is
provided with a 3-prong grounding plug which should not be removed or altered. Do not use this appliance with an ungrounded, 2-prong adapter. The cord must be plugged into a properly grounded GFCI-protected outlet. See INSTALLATION section of this manual.
13. Spiders and insects like to nest in the burners, venturis, valves, and orifices of a Side Burner,
disrupting the gas flow in the burner. This very dangerous condition can cause a fire behind the control panel, damaging the Side Burner and risking personal injury. If your Side Burner has been unused for a long time, inspect and clean the burners, venturis, valves, and orifices. It is recommended you inspect your Side Burner at least twice a year. See BURNER ADJUSTMENT section of this manual for details.
14. Keep the areas surrounding the Side Burner free from combustible materials, trash, or
combustible fluids and vapors such as gasoline or charcoal lighter fluid. Do not obstruct the flow of combustion gases and ventilation airways (front).
15. If your Side Burner is mounted on a grill cart, keep the rear area free and clear of debris, extra
LP cylinders, etc. Do not block the ventilation louvers of the cart.
16. If your Side Burner is mounted on a cart and stored indoors, ensure that it is cool before
moving. If propane is used, the LP cylinder must be disconnected and stored OUTSIDE in a well-ventilated area, out of the reach of children. A grill cover which covers the entire Grill + Side Burner is recommended, even when stored indoors.
17. Never move the Side Burner when hot. When in use, portions of the Side Burner are hot
enough to cause severe burns.
18. Always have an “ABC” type fire extinguisher accessible – never attempt to extinguish a grease
fire with water or other liquids.
19. Avoid wearing loose-fitting garments or long sleeves while cooking with the Side Burner.
They could ignite. For personal safety, wear proper apparel while cooking. Some synthetic fabrics are highly flammable and should not be worn while cooking.
20. Never let pot holders, covers, or other flammable materials come in contact with or too close
to any cooking grate, burner, or hot surface until it has cooled down sufficiently. Fabrics may ignite and result in personal injury. Use only dry potholders. Moist or damp potholders on hot surfaces may cause burns from steam. Do not use a towel or bulky cloth in place of potholders. Do not let potholders touch hot portions of the cooking grates.
21. Never touch the cooking grates or immediate surrounding metal surfaces with your bare
hands while cooking with the Side Burner, as these areas become extremely hot and could cause burns. Use only the handles and knobs provided for operation of the Side Burner.
6
©2018 Hestan Commercial Corporation
PRECAUTIONS - BEFORE YOU USE YOUR SIDE BURNER
22. Protect your hands with an insulated glove or mitt when operating the Side Burner. Always keep your face away and open lids slowly on pots and pans to allow heat and steam to escape before fully opening. Never lean over an open hot Side Burner.
23. The Side Burner metal cover must be removed while lighting. Leaving the cover in place while lighting can result in an explosion and personal injury, or death. Never lean over a Side Burner or look directly into the burner when attempting to light. See the LIGHTING INSTRUCTIONS section of this manual.
24. Do not heat unopened food containers (cans) as pressure build-up will cause the container to explode.
25. Do not use aluminum foil to line the burner bowl or the drip tray. This will alter the airflow to the burner or trap excessive heat in the control area. This can melt control knobs, wiring, or igniters, and increase the risk of personal injury. Such damage is specifically excluded from our warranty.
26. Never use the Side Burner without the drip tray in place and pushed all the way to the back. Without the drip tray, hot grease or oil from a spill-over can leak downward creating a fire or explosion hazard.
27. Grease is extremely flammable. Let hot grease cool before attempting to handle or dispose of it. Avoid letting excessive grease deposits collect by cleaning the drip tray often. Never clean while the Side Burner is on, or hot from recent use.
28. Cooking excessively fatty meats and oils will cause flare-ups or grease fires. Damage caused by them or by the Side Burner being left unattended, are not covered under the terms and conditions of our warranty.
(continued)
EN
29. Only certain types of glass, heatproof glass-ceramic, earthenware, or other glazed utensils are suitable for Side Burner use. However, these types of materials may break with sudden temperature changes. Use only on low or medium heat settings, and according to their manufacturers’ directions.
30. Do not lean on side shelves or place a load of more than 25 lbs (11.3 kg) on a side shelf.
31. Do not repair or replace any part of the Side Burner unless specifically recommended in this manual. All other warranty and non-warranty service should be referred to and performed by a qualified technician.
32. For proper lighting and performance of the burners, keep the ports clean. It is necessary to clean them periodically for optimum performance. The burners will operate only in one position and must be mounted correctly for safe operation. See BURNER ADJUSTMENT section of this manual.
33. Clean the Side Burner with caution. Avoid steam burns - do not use a wet sponge or cloth to clean the Side Burner while it is hot. Some cleaners produce noxious fumes or can ignite when applied to a hot surface. Be sure all Side Burner controls are turned off and the appliance is cool before using any type of aerosol cleaner on or around the appliance. The chemical that produces the spraying action could, in the presence of heat, ignite or cause metal parts to corrode. Clean and perform general maintenance on the Side Burner twice a year. Watch for corrosion, cracks, or insect activity. See the CLEANING AND MAINTENANCE section of this manual.
©2018 Hestan Commercial Corporation
7
EN
REGULATORY / CODE REQUIREMENTS
Installation of this cooking appliance must be made in accordance with local codes. In the absence of local codes, this unit should be installed in accordance with the National Fuel Gas Code
ANSI Z223.1/NFPA 54
Storage and Handling Code
All Electrical Components must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code code
CSA C22.1
STATE OF MASSACHUSETTS Massachusetts requires all gas be installed using a plumber or gas fitter carrying the appropriate Massachusetts license. All permanently installed natural gas or propane installations require a T handle type manual gas valve be installed in the gas supply line to this appliance. This does not apply to portable propane installations using a 20lb. cylinder.
CALIFORNIA PROPOSITION 65 - WARNING The burning of gas cooking fuel generates toxic by-products, which are on the list of substances which are known by the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure to such substances. To minimize exposure to these substances, always operate this unit according to the use and care manual, ensuring you provide good ventilation when cooking with gas. This warning is issued pursuant to California Health & Safety Code Sec. 25249.6.
.
, Natural Gas and Propane Installation code
B149.2
.
ANSI/NFPA 70
CSA B149.1
, or Canadian Electrical
, or Propane
PORTABLE LP GAS CYLINDERS
Use only a standard 20 lb. (9.1kg) liquid propane (LP) gas cylinder - 12.25” diam. X 18.25” H (31cm X 47cm) which features an Overfill Protection Device. The cylinder must be installed in the upright position. Do not use a dented or rusty LP cylinder as it may be hazardous and should be checked by your LP supplier. Never use a cylinder with a damaged valve. Never move or alter the gas fittings. Check the expiration date on the cylinder collar as well. Do not refill an expired cylinder, it must be replaced. If you buy refilled (exchange) LP cylinders, check this date as well.
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT). The cylinder must be provided with a shut off valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection type QCC1 in the standard for compressed gas cylinder valve outlet and inlet connections ANSI/CGA-V-I.
Certain liquid propane dealers may fill LP cylinders for use in the Grill / Side Burner beyond cylinder filling capacity. This “overfilling” may create a dangerous condition due to a build-up of excess pressure. As a safety device, there is a pressure relief valve which will vent propane gas vapor to relieve this excess pressure. This vapor is combustible and therefore can be ignited. To reduce this danger, you should take the following safety precautions:
1. When you have your cylinder filled, be sure you tell the supplier to fill it to no more than 80%
of its total capacity.
2. If you own or use a spare cylinder, you should NEVER store it near or under the grill/cart unit
or burner box, or near any other ignition or heat source (like a water heater or furnace).
IF THE INFORMATION IN 1 AND 2 ABOVE IS NOT FOLLOWED EXACTLY, A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR.
3. The LP cylinder must be disconnected and stored OUTSIDE in a well-ventilated area, out of
the reach of children.
4. Do not store a full cylinder in direct sunlight.
8
©2018 Hestan Commercial Corporation
LOCATING AND ASSEMBLING THE SIDE BURNER
When determining a suitable location for your Side Burner, take into account concerns such as exposure to wind, rain, sprinklers, proximity to traffic paths, and keeping any gas supply line runs as short as possible.
Locate the Side Burner only in a well-ventilated area. Never locate the Side Burner in a building, garage, breezeway, shed or other such enclosed areas without an approved ventilation system. Never locate the Side Burner over, under, or next to unprotected combustible construction.
Using the Side Burner in windy areas can disrupt the flame, especially on low or simmer settings. This may cause nuisance sparking of the igniter. Relocate to a less windy area. If the Side Burner is mounted in an enclosure (island), you may need to build a wind-break to avoid this issue in the future.
When installing a Side Burner or other gas appliance into an enclosure (island), the enclosure must be constructed with ventilation openings to avoid accumulation of gas should there be a leak. See the INSTALLATION section of this manual for details. Keep the area underneath the Side Burner free of debris.
Ensure all packaging, straps, etc. have been removed from the Side Burner. Remove any tie-down wires from the burners.
Keep the area underneath the Side Burner free of debris. If your Side Burner is mounted on a cart, engage the brakes on the casters to prevent movement of the cart.
Ensure that the burner cap is mounted correctly on the burner ring. Do not operate the Side Burner without the burner cap in place (see Fig. 1).
Figure 1
EN
INSTALLATION
CLEARANCES - NON-COMBUSTIBLE:
TO NON-COMBUSTIBLE CONSTRUCTION ABOVE THE COOKING SURFACE A minimum of 4” (10 cm) clearance from the rear of the appliance to non-combustible
construction is required. See diagrams on the following pages.
TO NON-COMBUSTIBLE CONSTRUCTION BELOW THE COOKING SURFACE The appliance may installed directly on non-combustible construction. See diagrams on the
following pages.
CLEARANCES - COMBUSTIBLE:
TO COMBUSTIBLE CONSTRUCTION ABOVE THE COOKING SURFACE A minimum of 12” (30 cm) clearance on the sides and the rear of the appliance to combustible
construction is required. Read warning below. See diagrams on the following pages.
TO COMBUSTIBLE CONSTRUCTION BELOW THE COOKING SURFACE The appliance may installed directly on combustible construction. See diagrams on the following
pages.
The minimum clearances to combustible materials means that ALL combustible materials must be outside this 12” (30 cm) zone. As an example, if you have an island with a stucco or tiled surface and wood-frame construction, the wood is considered combustible, even though the Side Burner is touching the stucco or tile surface, which is non-combustible. In extreme circumstances, the wood could potentially get hot enough to burn. Examples of other combustible materials are
©2018 Hestan Commercial Corporation
9
EN
INSTALLATION
compressed wood, plant fibers (bamboo), vinyl/plastic, or other materials capable of being ignited and burned. Materials that are flame-proofed or treated with flame-retardant are still considered combustible.
VENTILATION OPENINGS A minimum of three 10 in² (65 cm²) of ventilation openings must be provided for both left and right sides of your enclosure (island), as well as the back. These openings are required to safely dissipate gas vapors if there is a leak in your enclosure. See diagram below.
BUILT-IN DIMENSIONS (NON-COMBUSTIBLE):
(continued)
10
©2018 Hestan Commercial Corporation
INSTALLATION
BUILT-IN DIMENSIONS (COMBUSTIBLE):
(continued)
EN
BUILT-IN INSTALLATION
Your Hestan Side Burner comes ready to install into your enclosure (island). Proceed to the GAS CONNECTIONS section for further instruction.
INSTALLATION OF SIDE BURNER ONTO GRILL CART (MODEL AGB122 ONLY ­REQUIRES PANEL KIT AGBPK)
It is possible to mount your Hestan Side Burner to your grill cart. You will need to order Panel Kit AGBPK, available from your Hestan dealer. Instructions are provided with the kit.
©2018 Hestan Commercial Corporation
11
Hestan delivers the consistent control
GAS AND ELECTRICAL CONNECTIONS
GAS SUPPLY
The local gas authority or supplier should be consulted at the installation planning stage in order to establish the availability of an adequate supply of gas (NG or LP). If it is a new installation, have the gas authorities or supplier check the meter size and piping to assure that the unit is supplied with the necessary amount of gas supply and pressure to operate the unit(s).
Gas connections should be made by a qualified plumber, or your professional outdoor appliance installer.
All fixed (non-mobile) appliances must be fitted with an accessible upstream gas shutoff valve as a means of isolating the appliance for emergency shut off and for servicing.
Make certain new piping and connections have been made in a clean manner and have been purged so that piping compound, chips, etc. will not clog regulators, valves, orifices, or burners. Use pipe joint compound / thread sealant approved for natural and LP gases.
NEVER CONNECT THE SIDE BURNER TO AN UNREGULATED GAS SUPPLY. Before proceeding, ensure the appliance is fitted for Natural or Liquid Propane gas. Connecting to an improper gas type will result in poor performance and increased risk of damage or injury. Gas type and gas consumption (BTU per hour) for each burner type is shown on the rating label affixed to the underside of the drip tray.
Installation of this cooking appliance must be made in accordance with local codes. In the absence of local codes, this unit should be installed in accordance with the National Fuel Gas Code No. Storage and Handling Code
Z223.1/ NFPA 54
, Natural Gas and Propane Installation code
B149.2.
CSA B149-1,
or Propane
EN
NOTE: See rating label for manifold pressure for the type of gas of your appliance.
CONVERSION KITS
Gas conversion kits are available from your Hestan dealer should you need to convert an LP unit to NG, or vice-versa.
HIGH ALTITUDE KITS
If you live in a high altitude area, 2,000 ft. (610 m) or more above sea level, your Side Burner will require different orifices for proper combustion and performance. High altitude kits are available through Hestan Customer Service. Please have your model and serial number information ready when you call.
©2018 Hestan Commercial Corporation
13
EN
GAS AND ELECTRICAL CONNECTIONS
GAS CONNECTION - NATURAL GAS (NG)
NOTE: To ensure proper heating performance of this appliance, verify that the gas line supply pressure is adequate. Use only the gas pressure regulator supplied with this appliance. This regulator is set for a supply pressure of 7 inch WC (1.74 kPa) to maintain 4 inch WC (1.00 kPa) outlet (manifold) pressure. Use a minimum 1/2” ID flex hose to prevent gas starvation. Ensure that the service pipe supplying the side burner is fitted with a shut-off valve conveniently positioned and easily accessible as an emergency gas shut-off.
(continued)
HESTAN SIDE BURNER
(MODEL AGB122-NG SHOWN)
NAT GAS
REGULATOR
INCOMING
NAT GAS SUPPLY
SHUTOFF VALVE
1/2” ID FLEX HOSE,
ELBOW & NIPPLE
(SUPPLIED BY
CUSTOMER)
Your Hestan Side Burner for use with Natural Gas is supplied with its own regulator which MUST be installed. If this regulator needs to be replaced, use only the type specified by Hestan for this appliance.
To connect the regulator follow the next steps:
1. Locate the regulator mounted underneath your Side Burner.
2. Connect gas supply using a minimum 1/2” diameter flexible (semi–rigid) stainless steel gas
hose, no more than 48” (1.22m) in length. If you plan to inter-connect the Side Burner with your Hestan Grill, be sure to use the fittings supplied with the mounting kit, and a flexible hose as short as possible to make the connection. The hose as well as the connectors must comply with the
Homes, ANSI Z21.75 • CSA 6.27
thread sealant on all connections.
Standard for Connectors for Outdoor Gas Appliances and Manufactured
, and suitable for outdoor installation. Use the appropriate
(SUPPLIED BY
CUSTOMER)
14
3. Proceed to LEAK TESTING section.
©2018 Hestan Commercial Corporation
GAS AND ELECTRICAL CONNECTIONS
(continued)
GAS CONNECTION - LP PIPED SYSTEMS
An LP piped system is one with a large central LP tank that feeds an entire household. These systems are normally equipped with a high pressure regulator by the large LP tank, and low pressure regulators close to the home. The gas line connectors must comply with the
for Connectors for Outdoor Gas Appliances and Manufactured Homes, ANSI Z21.75 • CSA 6.27
and suitable for outdoor installation. The connection shall be 48” (1.22 m) or less.
NOTE: To ensure proper heating performance of this appliance, verify that the gas line supply pressure is adequate. The regulator must be set for a supply pressure of 11.0” WC (2.74 kPa) to maintain 10.0” WC (2.49 kPa) outlet (manifold) pressure. Use a minimum 1/2” ID flex hose to prevent gas starvation. Ensure that the service pipe supplying the Side Burner is fitted with a shut-off valve conveniently positioned and easily accessible as an emergency gas shut-off.
Standard
HESTAN SIDE BURNER
(MODEL AGB122-LP SHOWN)
EN
,
CONVERTIBLE
LP GAS
REGULATOR
INCOMING
LP GAS SUPPLY
SHUTOFF VALVE
1/2” ID FLEX HOSE,
ELBOW & NIPPLE
(SUPPLIED BY
CUSTOMER)
Your Hestan Side Burner for use with an LP Piped System is supplied with its own convertible regulator which MUST be installed. If this regulator needs to be replaced, use only the type specified by Hestan for this appliance.
To connect the regulator follow the next steps:
1. Locate the regulator mounted underneath your Side Burner.
(SUPPLIED BY
CUSTOMER)
2. Connect gas supply using a minimum 1/2” diameter flexible (semi–rigid) stainless steel gas hose, no more than 48” (1.22 m) in length. If you plan to inter-connect the Side Burner with your Hestan Grill, be sure to use the fittings supplied with the mounting kit, and a flexible hose as short as possible to make the connection. The hose as well as the connectors must comply with the
Homes, ANSI Z21.75 • CSA 6.27
thread sealant on all connections.
3. Proceed to LEAK TESTING section.
Standard for Connectors for Outdoor Gas Appliances and Manufactured
, and suitable for outdoor installation. Use the appropriate
©2018 Hestan Commercial Corporation
15
EN
2-STAGE LP
REGULATOR /
HOSE ASSEMBL Y
20 lb. LP TANK
(SUPPLIED BY CUSTOMER)
ADAPTER, 3/8 FLARE
X 1/2 NPT FEMALE
(SHIPPED LOOSE)
HESTAN SIDE BURNER
(MODEL AGB122-LP SHOWN)
ELBOW & NIPPLE
(SUPPLIED BY CUSTOMER)
RETENTION
DEVICE
(SHIPPED LOOSE)
GAS AND ELECTRICAL CONNECTIONS
(continued)
GAS CONNECTION - LIQUID PROPANE (LP) CYLINDER
Should you wish to connect your Hestan Side Burner to a standard 20 lb. LP gas cylinder, you will need to order kit AGCKLPT. This kit includes a two-stage regulator/hose assembly for connection to the tank, and a tank retention device. This regulator/hose assembly must be used WITHOUT alteration. If this assembly needs to be replaced, contact your Hestan dealer for genuine replacement P/N 014309.
NOTE: To ensure proper heating performance of this appliance, verify that the supply pressure is adequate. Use only the gas pressure regulator supplied with this appliance. This regulator is set to maintain 10 inch WC (2.49 kPa) outlet (manifold) pressure.
To connect the regulator / hose assembly follow these steps:
1. Locate the regulator and gas connection point in the rear right side of your Side Burner (in cart-
mounted models, remove the rear panel to gain access).
2. Connect the 3/8” Flare (compression flare fitting) X 1/2” NPT female adapter as shown. Then
connect the regulator/hose assembly to the adapter as shown. Use appropriate thread sealant on all connections.
3. Connect the regulator/hose assembly to a standard 20 lb. LP cylinder. If you plan to inter-
connect the Double Side Burner with your Hestan Grill, you will need Panel Kit AGBPK (as seen page 11). Be sure to use the included fittings and a flexible hose as short as possible to make the
16
connection. The hose as well as the connectors must comply with the
for Outdoor Gas Appliances and Manufactured Homes, ANSI Z21.75 • CSA 6.27
outdoor installation. Use the appropriate thread sealant on all connections.
4. Proceed to LEAK TESTING section.
©2018 Hestan Commercial Corporation
Standard for Connectors
, and suitable for
GAS AND ELECTRICAL CONNECTIONS
LP TANK RESTRAINT
If you purchased a Hestan Grill with Side Burner on a cart, be sure to restrain the LP cylinder by securing it with the retention bolt on the slide-out tray as shown below. It is important the tank does not fall over or stretch the hose which could cause a gas leak.
(continued)
2-STAGE
LP REGULATOR /
HOSE ASSY.
EN
TANK
RETENTION
BOLT
SLIDE-OUT T ANK TRAY
LEAK TESTING
GENERAL Although all gas connections on your Hestan Side Burner are leak tested at the factory prior to
shipment, a complete gas tightness check must be performed at the installation site due to possible movement in shipment, or excessive pressure unknowingly being applied to parts of the unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.
BEFORE TESTING
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water for leak testing purposes.
Apply the solution to the gas fittings by using a spray bottle or a brush.
For LP units, always check with a full LP cylinder.
20 LB.
LP TANK
(SUPPLIED BY
CUSTOMER)
©2018 Hestan Commercial Corporation
17
EN
GAS AND ELECTRICAL CONNECTIONS
To Test
Make sure all control valves are in the “OFF” position.
Apply the soap solution described above to all fittings.
Turn the gas supply on.
Check all connections from the supply line, or LP cylinder up to and including the manifold
pipe assembly and all connections to each burner.
Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas
supply, tighten any leaking fittings, turn the gas supply back on, and recheck.
If you cannot stop a gas leak, turn off the gas supply and call the dealer where you purchased
your Side Burner.
Do not use the Side Burner until all connections have been checked and do not leak. IMPORTANT NOTE - ALWAYS CHECK FOR LEAKS AFTER EVERY LP CYLINDER CHANGE.
If a leak is present, or if there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced before using the Side Burner. The hose and LP regulator are supplied as a complete assembly and must be replaced together. Do not attempt to repair or replace the hose itself. Contact your Hestan dealer for genuine replacement P/N 014309.
Check all gas supply fittings for leaks before each use. It is handy to keep a spray bottle of soapy water near the shut-off valve of the gas supply line. Spray all the fittings. Bubbles indicate leaks.
(continued)
ELECTRICAL SUPPLY
Important: This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes with the National Electrical Code,
ANSI/NFPA 70-1990
.
Appliances equipped with a flexible electrical supply cord are provided with a three-prong grounding plug. It is imperative that this plug be connected to a properly grounded three-prong receptacle. If the receptacle is not the proper grounding type, contact an electrician. Do not remove the grounding prong from this plug.
The Side Burner is designed for 120 volt AC power and must be plugged into a Ground Fault Circuit Interrupter (GFCI) protected circuit. Do not connect the Side Burner to the electrical supply until after gas connections have been made and leak checks have been performed.
KEEP ANY ELECTRICAL CORD AND FUEL SUPPLY HOSE AWAY FROM ANY HEATED SURFACES.
1. To protect against electric shock, do not immerse cord or plugs in water or other liquid.
2. Unplug from the outlet when not in use and before cleaning. Allow to cool before putting
on or taking off parts.
3. Do not operate any outdoor cooking gas appliance with a damaged cord or plug, or after the
appliance malfunctions or has been damaged in any manner. Contact the manufacturer for repair.
4. Do not let the cord hang over the edge of a table or touch hot surfaces.
5. Do not use an outdoor cooking gas appliance for purposes other than intended.
6. Use only a Ground Fault Circuit Interrupter (GFCI) protected circuit with this outdoor
cooking gas appliance.
18
©2018 Hestan Commercial Corporation
GAS AND ELECTRICAL CONNECTIONS
7. Never remove the grounding prong or use with a 2-prong ground adapter.
8. Use only extension cords with a 3-prong grounding plug, rated for the power of the equipment, and approved for outdoor use with a W-A marking.
(continued)
BURNER ADJUSTMENTS
Hestan Side Burners are similar to many residential gas cooktops. They do not have any adjustments, except for the correct orifices, and adjustment of the low setting on the valve.
BURNER FLAME ADJUSTMENT Each Side Burner is tested and adjusted at the factory prior to shipment. The proper orifice for
the gas type, and the air-fuel adjustment was made at this time. However, variations in the local gas supply, the elevation where you live, converting from one gas type to another, and other factors might make it necessary to adjust the burner flames.
The flames of the burners should be visually checked and compared with the figures below.
EN
Flames should be blue and stable with no yellow tips (LP units will have some yellow tipping). There should be no excessive noise or flame lifting. If any of these conditions exist, remove the burner cap and check if dirt, debris, spider webs, etc., are blocking the center venturi hole, or the individual burner ports. The occasional orange flame that quickly goes away is usually a small amount of dust or water condensation which is burning off - this is normal.
VALVE ADJUSTMENTS
The valves on your Hestan Side Burner are preset at the factory for optimum performance. However, the valve also features a low (simmer) adjustment if altitude, low-heat performance, converting from one gas to another, or other factors indicate an adjustment is needed.
NEVER ADJUST THE BURNER SO LOW THAT IT MAY GO OUT DURING USE. DO NOT OPERATE THE SIDE BURNER WITH THE LOW HEAT SCREW REMOVED. GAS CAN ESCAPE AND CAUSE A POTENTIALLY HAZARDOUS CONDITION.
©2018 Hestan Commercial Corporation
19
Loading...
+ 47 hidden pages