Package Contents
Lock Reader
Interface Cable,
System Side
Lock Body
K200-622
Cabinet Lock Series
Installation Instructions
Mounting
Template
Machine
screwwith
washer
Strike Plate
Double door bracket
Key Override Paddle
6 x 1/2”
3X
5/16”
3X
1”
1-1/4”
2X
2-56x3/8”
6-32 screws
1-5/8”
2X
1X
2X
HES, Inc.
Phoenix, AZ
1.800.626.7590
www.hesinnovations.com
Shaft Extension
0-80x½”
1X
1-3/4”
1-7/8”
2X
2X
2-56x1-1/4”
1X
2‐1/2”
2X
Recommended Tools
Drill, Drill bits: 5/32”, 1/2”
Approved Credential:
i.e. iCLASS or Prox ID card
Phillips drivers P0, P2
Pencil, Wire Stripper
Specifications
Voltage: 12–24 VDC ±10% (Power Supply not provided)
K200-622 (Reader) Current Consumption:
12 VDC: 38 mA peak for Red and Green LED only
226 mA peak for Red and Green LED and Motor Drive
24 VDC: 17 mA peak for Red and Green LED only
118 mA peak for Red and Green LED and Motor Drive
Operating Temperature: -10C to 50C
Holding Force: 250 lbs
Interface Cable, Lock Side
Optional:
Cam lock for key override
Part Number 3085006.001, Rev. B 1
External Interface Signals Summary:
From/To
Lock Signal
Name
P1-1/J1-1
P1-12/J1-2
Vin
Tamper / Door
Position +
Lock Signal
Direction and Wire
Color
Input,
Red/24 AWG
Output,
Yellow/24 AWG
Electrical Interface Logic
Power to Reader Input Power
Dry Contact
(0–35 VDC, <100mA)
Open = Unlocked
Closed = Locked
P1-3/J1-3
P1-4/J1-4
P1-5/J1-5
P1-6/J1-6
P1-7/J1-7
P1-8/J1-8
Lock
Tamper / Door
Position –
Wiegand Data 0
Green LED
Wiegand Data 1
Red LED
Input,
Violet/24 AWG
Output,
Blue/24 AWG
Output,
Green/24 AWG
Input,
Brown/24 AWG
Output,
White/24 AWG
Input,
Orange/24 AWG
Wetted Relay Contact
Closure
(0–35 VDC)
Dry Contact
(0–35 VDC, <100mA)
0–5 VDC Active Low
0–5 VDC Active Low
0–5 VDC Active Low
0–5 VDC Active Low
Active High
Open = Unlocked
Closed = Locked
P1-10/J1-10
P1-9/J1-9
Ground
Ground
Input,
Black/24 AWG
Input,
Gray/24 AWG
– –
– –
LED Function: LED states are controlled and defined by the User’s EAC. Enabling the red and green LEDs on
the K200 occurs via an active low (ground) signal.
Output Type: SIAAC-01-1996 Wiegand Output Compliant.
FCC Part 15, Compliant, Industry Canada Compliant
BHMA: A156.3, A156.36, A156.25 Compliant
NOTE: Contact HID Global Technical Support at (866) 607-7339 for additional configuration cards to enable
the credential capabilities of “iCLASS Elite” and “NFC over HCE.”
Credentials Supported: 125 kHz Proximity or 13.56 MHz iCLASS, iCLASS Elite, iCLASS SEOS, iCLASS SE,
ISO 15693 ICLASS, ISO 14443A Mifare, Mifare Plus, Desfire SE, Desfire EV1, and NFC over HCE.
Part Number 3085006.001, Rev. B 2
SYSTEM OVERVIEW
The K200-622 wired cabinet lock (K200) extends access control to a cabinet or drawer. The K200 lock is capable
of reading radio-frequency identification (RFID) credentials and providing that credential data to an electronic
access control (EAC) system via Wiegand data signaling. The EAC is responsible for determining whether user
access should be granted or denied. When the EAC provides an active-high unlock signal to the lock in the access
granted case, the K200 drives a motor to complete the unlock/lock cycle. EAC indication of user access/denial is
provided to the user by way of LED control inputs on each lock. Additional lock monitoring features (e.g., door
position, tamper) are monitored within the lock and status of each is provided to the EAC.
MOUNTING THE LOCK
NOTE: The K200 reader and lock body can be oriented in several ways to accommodate various cabinets and
drawers. When selecting an orientation, it should be noted that some reader orientations may prevent use
of the key override function. For example, in the door handing shown here, the key override paddle cannot
be accessed in orientation “A”, but it can be accessed in orientations “B,” “C” and “D”.
1. ESTABLISH the horizontal centerline of the latch.
a. HOLD the lock body to the inside of the door and POSITION it generally where you would like it to mount.
b. LOCATE lock centerline notch on the latch, and MARK this point on the inside of the cabinet door using a
pencil.
c. DRAW the horizontal latch centerline from this mark on the inside of the cabinet door and TRANSFER it to the
outside of the cabinet door.
d. TRANSFER this centerline to the inside of the cabinet or the second door on a double-door cabinet.
Part Number 3085006.001, Rev. B 3
2. TRANSFER the location of the inside wall of the cabinet to the door.
a. MEASURE the horizontal distance between the inside edge of the cabinet and the door edge.
NOTE: The drawn line depicts the location of the strike mounting surface.
b. LOCATE the lock centerline notch on the latch and MARK this point on the inside of the cabinet door using a
pencil.
c. DRAW the horizontal latch centerline from this mark on the inside of the cabinet door and TRANSFER it to the
outside of the cabinet door.
Part Number 3085006.001, Rev. B 4