HES 9400-605, 9400-605-LBM, 9400-605-LBSM, 9400-606, 9400-606-LBM Installation Instructions

...
HES 9400/9500/9600 Electric Strike
Installation Instructions and Frame Preparation
Product Components
A 9400/9500/9600 Strike Body
B 9400/9500/9600 Cover
C 1/4"-20 x 1" Mounting Screws
E #6-32 x 1/4" Cover Screws
F 5/64" Hex Key
G 12-Volt and 24-Volt Pigtails
Electrical Specifications
Electrical Ratings for Solenoid
Continuous Duty 12 V DC 24 VDC
Resistance in Ohms 24 96
Amps .50 .25
Diagram 1: Product Components
A
B
Solenoids are rated at +/- 10% indicated value.
Minimum Wire Gauge
Requirements
(Based on Round Trip)
200 feet or less 18 gauge 22 gauge
200 – 300 feet 16 gauge 22 gauge
300 – 400 feet 16 gauge 20 gauge
Solenoid Voltage
12 V DC 24 VDC
C
F
G
D
E
1
Installation
CAUTION Before connecting any device at the installation site, verify input voltage using a multimeter.
Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage exceeding 10% of the solenoid rating may cause severe damage to the unit and will void the warranty.
Preparing the Strike
NOTE: For 12 VDC, the Plug In Connector (pigtail)
marked “12 VDC” should be used; for 24 VDC, the pigtail marked “24 VDC should be used.
1 SELECT the appropriate pigtail that
matches system power and electrically CONNECT as illustrated in Diagram 2.
2 IF no connector is present,
THEN CONFIGURE the wires as shown in Diagram 2.
3 IF using the Latchbolt Monitor (LBM)
or Latchbolt Strike Monitor (LBSM), THEN REFER to Diagrams 3 and 4 on Page 3 to complete wiring.
Diagram 2: 12V to 24V Conversion
or
NOTE 1: The 9400/9500/9600 ships in FAIL SECURE OPERATION mode.
NOTE 2: FAIL SAFE OPERATION mode should not be used in fire or windstorm-rated applications.
4 CONVERT the 9400/9500/9600 to
FAIL SAFE OPERATION, if needed, using Diagrams 5 and 6 on Page 3 as a guide.
Preparing the Frame
NOTE: When using a Corbin Russwin Series
5000 or Yale 7000 series equipped with an offset deadlatch, the deadlatch is located just above the Vertical Alignment line, as shown on the Installation Template on Page 4.
1 PREPARE the door jamb using
the Installation Template located on Page 4 (with the exception of the hole for final lockdown).
If Connector Is Missing
Connect Together
(+ 12 VDC)
(-NEG)
Connect Together
(+ 24 VDC)
(-NEG)
Strike
Electric
Red/green
Strike
Electric
Red/green
Red
Violet
Black
Red
Violet
Black
Connect Together
2
Finishing the Installation
1 Electrically CONNECT the 9400/9500/9600
to the Plug In Connector, and ATTACH the electric strike to the jamb using the 1/4"-20 x 1" mounting screws provided.
2 CHECK latchbolt interaction to determine
if horizontal adjustment is needed, and ADJUST as needed; then LOCK DOWN the horizontal adjustment using the #10-32 set screws as illustrated on Page 4.
3 OPTIONAL LOCKDOWN FEATURE:
INSTALL the #10-24 UNC or 10-32 UNF lockdown screw if additional security is required; however, REMOVE the strike before drilling hole.
4 INSTALL the cover plate, and SECURE
in place using the #6-32 x 1/4" Cover Screws as illustrated on Page 4.
Converting the
Diagram 3
Latchbolt Monitor
White Common Orange Normally Open Green Normally Closed
White Brown
Orange Blue
Green Yellow
Diagram 5: Fail Secure Operation
Diagram 4
Latchbolt Strike Monitor
Brown Common Blue Normally Open Yellow Normally Closed
Operation Mode
NOTE 1: The 9400/9500/9600 series
Electric Strikes are pre-set for FAIL SECURE OPERATION as shown in Diagram 5.
NOTE 2: There are Selector Stop Pins, one on the left side and one on the right side. Both Selector Stop Pins must be repositioned to convert the strike to FAIL SAFE OPERATION.
1 To convert to FAIL SAFE OPERATION,
REMOVE the Selector Stop Pins on each side of the strike body using the provided 5/64" hex key.
2 MOVE the Selector Stop Pins to the FAIL SAFE
OPERATION position (towards the center of the strike) as pictured in Diagram 6.
3 TIGHTEN both Selector Stop Pins after
they have been moved to the FAIL SAFE OPERATION position using the 5/64" hex key.
Verifying the
Selector Stop
Pin Location
Diagram 6: Fail Safe Operation
Operation Mode
NOTE: Both keepers should be unlocked without
power, but lock when power is applied.
1 VERIFY that both keepers are
in FAIL SAFE OPERATION.
Selector Stop
Pin Location
3
USE this line as a reference to center deadlatch**
Frame Preparation
Adjusting Horizontal and Lockdown
1 LOOSEN the two 1/4"-20 x 1" mounting screws.
2 ADJUST strike to appropriate horizontal position
3 TIGHTEN the two 1/4"-20 x 1" mounting screws
4 SECURE the adjustment by tightening the set screws
5 INSTALL the #10-32 UNF or 10-24 UNC lockdown screw (optional).
Set Screw
Location
Mounting
Screw
Lockdown
Screw
(optional)
Template
NOTE: May not be to scale. For easy installation,
the template should be ordered.
1-3/4"
[44.5mm]
1/2" [12.7mm] Clearance
for
LBM/LBSM
Wiring
10-24 UNC Screw (optional)
Final Lockdown Feature 10-32 UNF or
1-1/16"
1-5/16"
[33.3mm]
[27mm]
4-1/8"
[104.8mm]
This edge
toward
door
Installing the Cover
1 ATTACH the cover using the
#6-32 x 1/4" Cover Screws
Set Screw
Location
Mounting
Screw
[228.6mm]
1-5/16"
[33.3mm]
9"
** See note prior to
Step 5 on Page 2
7/8"
[19mm] Clearance for Power
Wiring
[22.5mm]
3/4"
2X
Mounting
Hole
Locations
for
1/4-20 UNC
Mounting
Screws
7/8"
4X
[22.5mm]
Centerline
of Latchbolt
4-1/8"
[104.8mm]
Deadlatch Vertical Alignment.
techsupport.esh@assaabloy.com | assaabloyesh.com
800.626.7590 | 10027 S. 51st Street Phoenix, AZ 85044 USA
4
3026006. 002 rev D Copyright © 2018, Hanchett Entr y Systems, Inc., an A SSA ABLOY Group compan y. All rights r eserve d. Reproduc tion in who le or in part w ithout th e expr ess writ ten permis sion of Hanche tt Entr y Systems, I nc. is prohibi ted.
Loading...