HES 7000-12-24, 7000-LBM, 7000C-630, 7000C-630-LBM, 783S-613E Installation Instructions

...
Cutout Templates (continued)
4
7000 Series Electric Strike
NOTE 1: For use with RIM exit devices in metal jambs with up to a 3/4” pullman
8-1/4”
[209.55]
latch.
3-3/8”
NOTE 2: Compatible with
[85.72]
American Device, Arrow, Dor-O-Matic, Monarch, Precision, Sargent. Von Duprin, and Yale.
NOTE 1: For use with RIM exit devices in aluminum jambs and surface mounted vertical rod exit devices with up to a 3/4” pullman latch. Includes keeper socket adapter.
5-3/4”
[146.05]
3-3/8”
[85.72]
NOTE 2: Compatible with American Device, Arrow, Dor-O-Matic, Jackson, Monarch, Precision, Sargent, Von Duprin, and Yale.
8-1/4”
NOTE 1: For use with RIM
[209.55]
exit devices in aluminum jambs with up to a 3/4” pullman latch. Includes keeper pocket
3-3/8”
[85.72]
adapter.
NOTE 2: Compatible with American Device, Arrow, Dor-O-Matic, jackson, Monarch, Precision, Sargent. Von Duprin, and Yale.
1-13/32”
[35.71]
HES, Inc.
3021006.002, Revision 3
Phoenix, AZ 85044 800-626-7590 www.hesinnovations.com
11/16”
[17.46]
1-13/32”
[35.72]
11/16”
[17.46]
1-13/32”
[35.72]
CL
25/32”
[19.72]
23/32”
[18.24]
CL
3/8”
[9.52]
CL
3/8”
[9.52]
783S OPTION
1-17/32”
[38.89]
786S OPTION
1-17/32”
[38.89]
789S OPTION
1-3/4”
[44.45]
1-11/16”
[42.86]
[209.55]
9-1/8”
[231.78]
Copyright © 2017, Hanchett Entry Systems, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Hanchett Entry Systems, Inc. is prohibited.
8-1/4”
1-3/4”
[44.45]
8-1/4”
[209.55]
1-3/4” [44.5]
5-3/4”
[146.05]
9”
[228.60]
9”
[228.60]
[165.10]
1/2”
[12.70]
6-1/2”
1-11/16”
[42.85]
3-3/8” [85.72]
Inches [mm]
11/16”
[17.45]
[12.70]
1-11/16”
[42.85]
3-3/8”
[85.72]
1-11/16”
[42.85]
3-3/8”
[85.72]
1/2”
(Model 7000-106)
Installation Instructions
Product Components
7000 Series Electric Strike Body
From Electric Strike
Specifications
ELECTRICAL RATINGS (Solenoid)
VOLTAGE
CONTINUOUS DUTY
INTERMITTENT DUTY*
7000 Series: For Indoor Use Only
Solenoids are rated at +/- 10% indicated value. * Applies to AC Only: 10% max duty cycle (2 min. max on time)
12 VDC 24 VAC
0.24A
24 VDC
0.12A
- -
Ratings
791/792 783S/786S/789S
Static Strength: 1,500 lbs 1000 lbs Dynamic Impact: 70 ft-lbs 50 ft-lbs Endurance: 500,000 cycles 500,000 cycles
ASSA ABLOY, the global leader in door opening solutions
12–16 VAC
- -
0.24–0.32A
Pigtail Connectors
MINIMUM WIRE GAUGE REQUIREMENTS
200 feet or less
0.12A
200 - 300 feet
300 - 400 feet
or
From Power Source
VOLTAGE
12 VDC 24 VDC
18 gauge
16 gauge
14 gauge
20 gauge
18 gauge
16 gauge
UL294 Performance Levels
Destructive Attack: Level 1 (No attack test) Line Security: Level I (No Line Security) Endurance: Level IV (100,000 cycles) Standby Power: Level I (No secondary power source)
1
Installation
2
Installation (continued)
3
NOTE 1: Before electrically connecting the device, the input voltage must be verified using a multimeter. Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage exceeding 10% of the electrical specification (See Page 1) may cause severe damage to the unit and will void the warranty.
NOTE 2: Installation wiring for the product and wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70.
Preparing the Frame
1. PREPARE door jamb per the appropriate template detail (see pages 3–4).
Finishing the Installation
NOTE: For 12 VDC, the Plug In Connector (pigtail)
marked “12 VDC” should be used; for 24 VDC, the pigtail marked “24 VDC” should be used.
1. CONNECT power to the electric strike, and INSTALL into jamb using the hardware provided with the option kit.
Fail Secure Mode
Cotter Pin
“D” Washer
Fail Safe Mode
Converting the Operation Mode
NOTE: The suitability of the locks in the FAIL SECURE
OPERATION mode is up to the local Authority Having Jurisdiction (AHJ) and emergency exit hardware may be required in such installations.
“D” Washer
Solenoid Slot
Adjusting the Horizontal in the 791 and 792 Options
1. LOOSEN the screws (a), but DO NOT REMOVE.
2. SHIFT the electric strike to the proper horizontal position and TIGHTEN the screws (a).
Cutout Templates
NOTE: For use with Cylindrical locksets up to 5/8” throw.
1-1/4”
[31.75]
791 Option
a
1-1/4”
[31.75]
1-5/8”
[41.28]
Inches [mm]
1-3/16” [30.48]
1. Because the electric strike ships in fail secure mode, COMPLETE the following steps to convert to fail safe mode.
a. REMOVE the cotter pin from the solenoid linkage.
Solenoid Slot
b. REMOVE the solenoid mounting screw and washers.
c. REMOVE the solenoid from the keeper module.
d. TURN the solenoid upside down, and RE-INSERT it into the keeper module.
e. RE-INSTALL the mounting screw and washers at the opposite end of the keeper module, and ENSURE the “D” washer is positioned firmly into the solenoid slot.
White (Common) Orange (Normally Open) Green (Normally Closed)
f. REPLACE the cotter pin to secure the solenoid linkage.
Figure 1. Converting the Operation Mode
Figure 2: LBM Wiring
NOTE: For use with Cylindrical locksets up to 5/8” throw.
7-15/16” [201.61]
1-3/16” [30.18]
4-7/8”
[123.82]
5/32”
[3.96]
3-3/8”
[85.72]
4-7/8”
[123.82]
CL
4-1/8”
[104.78]
4-7/8”
4-1/8”
[104.78]
5/32”
[4.02]
1-19/32”
[40.52]
3-3/8”
[85.72]
792 Option
1-7/16” [36.51]
CL
3-3/8”
[85.72]
1/4”
[6.35]
[44.45]
1-3/4”
[31.75]
7-15/16” [201.63]
[188.95]
1-7/16”
7-7/16”
1-5/8”
[41.28]
1-3/16” [30.48]
3-3/8”
[85.72]
1-7/32” [30.96]
5/32”
[4.02]
1-19/32”
[40.52]
Loading...