Hercules 35283, 35291 User Manual

SAFETY DATA SHEET
1. Identification
Hercules Cyrotek-100 ALProduct identifier
Other means of identification
Product code
Synonyms Recommended use Recommended restrictions Manufacturer/Importer/Supplier/Distributor information
Company Name
Address
7313E Part Numbers: 35283, 35291 Engineered Heat Transfer Fluid for Aluminum boilers None known.
HCC Holdings, Inc. an Oatey Affiliate 4700 West 160th Street Cleveland, OH 44135
Telephone
E-mail
Transport Emergency
Emergency First Aid
Contact person
2. Hazard(s) identification
Physical hazards Health hazards OSHA defined hazards Label elements
Hazard symbol
Signal word
Hazard statement
Precautionary statement
Prevention Response Storage Disposal
Hazard(s) not otherwise classified (HNOC)
216-267-7100 info@oatey.com Chemtrec 1-800-424-9300 (Outside the US 1-703-527-3887) 1-877-740-5015 MSDS Coordinator
Not classified. Not classified. Not classified.
None. None.
The mixture does not meet the criteria for classification.
Observe good industrial hygiene practices. Wash hands after handling. Store away from incompatible materials. Dispose of waste and residues in accordance with local authority requirements. None known.
3. Composition/information on ingredients
Mixtures
CAS number %Chemical name
57-55-6 55-65Propylene glycol
7732-18-5 45-55Water
N/A 1-5NJTSR #31348300 5065P
*Designates that a specific chemical identity and/or percentage of composition has been withheld as a trade secret.
4. First-aid measures
Inhalation
Skin contact
Hercules Cyrotek-100 AL SDS US 925784 Version #: 01 Revision date: - Issue date: 22-April-2015
If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing. Call a physician if symptoms develop or persist.
Rinse skin with water/shower. Get medical attention if irritation develops and persists.
1 / 6
Eye contact Ingestion Most important
symptoms/effects, acute and delayed
Indication of immediate medical attention and special treatment needed
General information
5. Fire-fighting measures
Suitable extinguishing media Unsuitable extinguishing
media Specific hazards arising from
the chemical Special protective equipment
and precautions for firefighters Fire fighting
equipment/instructions Specific methods General fire hazards
Rinse with water. Get medical attention if irritation develops and persists. Rinse mouth. If ingestion of a large amount does occur, call a poison control center immediately. Direct contact with eyes may cause temporary irritation.
Treat symptomatically.
Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves.
Alcohol resistant foam. Water fog. Dry chemical powder. Carbon dioxide (CO2). Do not use water jet as an extinguisher, as this will spread the fire.
During fire, gases hazardous to health may be formed.
Self-contained breathing apparatus and full protective clothing must be worn in case of fire.
Move containers from fire area if you can do so without risk.
Use standard firefighting procedures and consider the hazards of other involved materials. No unusual fire or explosion hazards noted.
6. Accidental release measures
Personal precautions, protective equipment and emergency procedures
Methods and materials for containment and cleaning up
Environmental precautions
Keep unnecessary personnel away. For personal protection, see section 8 of the SDS.
Large Spills: Stop the flow of material, if this is without risk. Use water spray to reduce vapors or divert vapor cloud drift. Dike the spilled material, where this is possible. Cover with plastic sheet to prevent spreading. Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water.
Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Never return spills to original containers for re-use. For waste disposal, see section 13 of the SDS. Avoid discharge into drains, water courses or onto the ground.
7. Handling and storage
Precautions for safe handling Conditions for safe storage,
including any incompatibilities
Avoid prolonged exposure. Use care in handling/storage. Store in original tightly closed container. Store away from incompatible materials (see Section 10
of the SDS).
8. Exposure controls/personal protection
Occupational exposure limits
US. Workplace Environmental Exposure Level (WEEL) Guides
Components
57-55-6)
Biological limit values Appropriate engineering
controls
Individual protection measures, such as personal protective equipment
Eye/face protection
Skin protection
Hand protection
Hercules Cyrotek-100 AL SDS US 925784 Version #: 01 Revision date: - Issue date: 22-April-2015
No biological exposure limits noted for the ingredient(s). Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates
should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.
Wear safety glasses with side shields (or goggles).
Wear appropriate chemical resistant gloves.
Type
TWA 10 mg/m3 Aerosol.Propylene glycol (CAS
Value
Form
2 / 6
Loading...