This manual i s copyrighte d by Heraeus Electro-Nite. No part of this document
may be reproduced, transmitted, transcri be d, stored in any retri ev al s y s te m , or
translated i n to any lang uage by any m ea ns without t h e express wri tten
permission o f Heraeus Electro-Nite.
Heraeus Electro-Nite makes no warranties as to t he co nt ents of thi s
documentation and specifically any implied warranties of merchantability or
fitness for any parti c ular purpos e.
Heraeus Electro-Nite further reserves the right to alter the specification of the
product wit hou t obligation to noti fy any per s on or or ga niz ati on of thes e
changes.
Improveme nts or instr u m en t changes ad d ed after this document w as pr inted
are to be found o n one or mor e pag es enc l ose d at the en d of t his man ual.
We ask you to take not e o f t he s e extra sheet s.
All instrument boards contain electronic components that can be damaged by electrostatic discharg e. Thes e
boards should only be handled by qualified personnel. The necessary safety precautions and security guidelines
must be observed during maintenance and service on the instrument.
Trademarks: All brand names and product names included in this manual are trademarks, registered
trademarks, or trade names of their respective holders.
PosithermP
P
and Checkmate are registered trademarks of Heraeus Electro-Nite.
File name:Digilance V_1.01
Version: 1.01
Page 2 of 21 Digilance V 26 November 2018
File name:Digilance V_1.01
Version: 1.01
26 November 2018 Digilance V page 3 of 21
Table of contents
1 Safety and usage notes ................................................................................................................................... 4
1.1 General ..................................................................................................................................................... 4
1.8 Disposal of instrument or parts ................................................................................................................. 6
1.9 CE-Declaration of Conformity ................................................................................................................... 7
1.10 ISED Canada and FCC Compliance Notice .............................................................................................. 7
3.1 Instrument transport mode ........................................................................................................................ 9
3.2 Shipping of ESD-sensitive modules .......................................................................................................... 9
3.3 Packaging the instrument ......................................................................................................................... 9
3.4 Shipment of Lithium Ion Batteries in the Instrument ................................................................................. 9
4 Standard Operation ........................................................................................................................................ 10
4.1 First Use ................................................................................................................................................. 10
4.4 Measurement History .............................................................................................................................. 13
4.5 Additional Measurement Information ...................................................................................................... 13
4.5.1 Working with Heat Numbers ............................................................................................................ 13
4.5.2 Working with Measurement Places .................................................................................................. 13
4.7 Power Management ................................................................................................................................ 15
7.5 Performing a test measurement with a Checkmate ................................................................................ 18
7.6 Calibrating the system ............................................................................................................................ 18
9 Technical data ................................................................................................................................................ 20
10 Spare Parts ................................................................................................................................................ 21
File name:Digilance V_1.01
Version: 1.01
This pictogram, is intended to alert the user to the presence of important operating and
This pictogram is used in relation to Danger, Warning, and Caution notices.
Page 4 of 21 Digilance V 26 November 2018
1 Safety and usage notes
1.1 General
This manual provides the information required to use the instrument. It is written for technically qualified
personnel such as engineers, programmers, or maintenance specialists who have been specially trained and
who have the specialized knowledge required in the field of instrumentation, electronics, and control.
This manual is an integral part of the instrument or device even if, for logistical reasons, it has to be ordered
separately. For the sake of clarity, not all details of all versions of the instrument or device are described, nor can
it cover all conceivable cases regarding installation, operation, and maintenance. If you require further
information, or face special problems that have not been dealt with in sufficient detail in this manual, contact
Heraeus Electro-Nite.
We would also point out that the contents of this manual shall not become a part of, or modify, any prior or
existing agreement, commitment, or legal relationship. The Purchase Agreement contains the complete and
exclusive obligations of Heraeus Electro-Nite. Any statements contained in this manual do not create new
warranties or restrict the existing warranty.
1.2 Qualified personnel
Only qualified personnel should be allowed to work on this instrument or device. Non-compliance with the
warnings contained in this manual or appearing on the instrument or device itself can result in severe personal
injury or damage to property. Qualified personnel include:
•System planning and design engineers who are familiar with the safety concepts of automation equipment,
instruments, or el ectr on ic dev ic es.
•Operating personnel who have been trained to work with automation equipment, instruments, or electronic
devices, and ar e conversant w ith the content of t he manual in as far as it is connecte d with the actual o peration
of the instrum ent or dev ic e.
•Commissioning and service perso nnel who are tra ined to repai r such equipmen t, instrume nts, or electron ic
devices, and who are authorized to energize, de-energize, clear, ground, and tag circuits, equipment, and
systems in accordance with established safety practices.
1.3 Danger notices
The notices and guidelines that follow are intended to ensure personal safety, as well as protecting the
instrument or device and any connected equip ment aga ins t damag e.
The safety notices are warnings for protection against loss of life (yours or service personnel) or for protection
against damage to property and are highlighted in this manual by the terms and pictograms defined here. The
terms used in this manual and marked on the instrument or device itself have the following significance:
Danger: Indicates that death, severe personal injury, or substantial property damage will result if proper
precautions are not taken.
Warning: Indicates that death, severe personal injury, or substantial property damage can result if proper
precautions are not taken.
Caution: Indicates that minor personal injury or property damage can result if proper precautions are not taken.
Note: Indicates important information about the product, its operation, or a part of the manual to which special
attention is drawn.
Attention: Hints in this documentation to special safety-related guidelines, which equate to the safety level of
Caution and Note.
maintenance (servicing) instructions on the literature accompanying the instrument or
device.
File name:Digilance V_1.01
Version: 1.01
According to the EU Directive 2002/96/EC Waste Electrical and Electronic Equipment (WEEE),
26 November 2018 Digilance V page 5 of 21
1.4 Proper usage
•T he instrume nt or in strum ent c ompo nent s may only be used for the applic atio ns des cri bed i n the manual or
the technical description, and only in combination with the equipment, components, and devices of other
manufacturers as far as this is recommended or permitted by Heraeus Electro-Nite.
•The instrument described has been developed, manufactured, tested, and the manual compiled in keeping
with the relevant safety standards. Consequently, if the handling instructions and safety guidelines described
for planning, installation, operation, and maintenance are adhered to, the instrument or device, under normal
conditions, will not be a source of danger to property or life.
1.5 RoHS regulations
All electrical devices sold in the European market from the 1 July 2006 must fulfil the EU Directive 2002/95/EC,
and RoHS 2 directive 2011/65/EU, on the Restriction of the use of certain Hazardous Substances in Electrical
and Electronic Equipment (RoHS) as well as the national laws derived from it. According to the definition in
Annex IB of the EU Directive 2012/19/EU WEEE, Heraeus Electro-Nite measuring instruments and analysis
devices belong to category 9 - monitoring and control instruments.
All Heraeus Electro-Nite instruments placed on the market after 1 July 2006 do not contain mater ial s prohib ited
according to the RoHS directive.
Affected parts and components are identif ied and adap ted to the statutory requirements and other subst anc es in
those parts and components are utilized where necessary. The quality and usability of our devices are not
affected.
The adaptations are usually not visible, although adapted primary housing parts can show different surface color.
1.6 WEEE regulations
all electrical devices sold in the European market from the 13 August 2005 must be marked with
a special symbol. This symbol (crossed out waste disposal receptacle with thick black bar
underneath) indicates to the customer that the device must not be placed in household waste,
but must be either deposited at a collection place for commercial scrap or returned to the
manufacturer.
Heraeus Electro-Nite devices are exclusively for commercial use and may not be transferred to private use.
Devices must be disposed of according to the national, statutory regulations for commercial electrical scrap. You
must also follow the EU Directive WEEE regulations and their national conversion. If in doubt, ask your national
importer or Heraeus Electro-Nite.
All old Heraeus Electro-Nite devices can be deposited at Heraeus Electro-Nite premises, free of charge and
using a certificated disposal company. The customer pays only for the carriage.
File name:Digilance V_1.01
Version: 1.01
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.