Henny Penny FM01-875 Service Manual

IMPORTANT ADDITIONAL INFORMATION FOR CONTROL RETROFIT INSTRUCTIONS FM01-875
PAGE 1-4, PROBE INSTALLATION INSTRUCTIONS
Tighten compression nut on probe finger-tight, and then tighten ½-turn with a ½ inch wrench. Do not over-tighten, or damage to the probe could result.
PAGE 1-5
When installing the 24 VAC solenoid coil, clean the grease build-up from the solenoid assembly.
Before installing the 2 sheets of insulation against the frypot wall, scrape any grease build-up around the electrical components on the control compartment deck, on the side walls, and the frypot wall, especially around the high limit and probe fittings.
PAGE 1-6 Attach ground wire, supplied in kit, to stud on control panel. See photo below
When wire tying the wires, make sure the high limit capillary tube runs under and away from all electrical power wires. The tube must never be in contact with the electrical power wires or terminals, or electrical shock or component damage could result.
page 1
FM07-016
IMPORTANT ADDITIONAL INFORMATION FOR CONTROL RETROFIT INSTRUCTIONS FM01-875
480 VOLT FRYERS
Step 6, page 1-2 of instructions, on 480 volt units, mark the wires that you remove from primary contactor and fuse holders that go to the 480 to 240 stepdown transformer in the back of the fryer. The contactor wires will be reconnected to the new primary contactor, and the fuse wires will be reconnected to the fuse holders. It is important that these wires be reconnected properly or damage to the control will result.
Step 5, page 1-5 of instructions,
reconnected properly or damage to the control will result. The input voltage to the control must not exceed 240 VAC.
Remove the wires from the L1 & L2 terminals of the primary contactor that go to the fuses of the new contactor assembly-they are not used on 480V units. labeled wires that were disconnected in step 6C, Section 1-2, from the primary contactor to the L1 & L2 terminals of the new primary contactor.
Reconnect the labeled wires that were disconnected from the fuse holders in step 6C, Section 1-2, to the center terminal of the new fuse holders on the new contactor mounting bracket.
FM07-016
On 480 volt units, the 480V to 240V wires must be
Reconnect the