Henkel, Inc.
P.O. Box 1322 * Hammond, Louisiana * 70404 * (985) 345-2171
www.keenovens.com
Model KHTF-600 Re-bake Flux Oven
Installation Instructions & Repair Parts List
One Year Limited Warranty
Henkel, Inc. warrants its products against defects in material and workmanship. Henkel,
Inc. will either repair or replace without charge any properly installed product which fails
under normal operating conditions within one year from date of installation, provided it is
returned to our factory, transportation prepaid, and our inspection determined it to be
defective under the terms of this warranty. The warranty covers only equipment
manufactured by Henkel, Inc., and does not extend to transportation, installation, or
replacement charges at the buyers’ facility; nor does it apply to any other equipment of
another manufacturer used in conjunctions with Henkel, Inc. equipment. No other
warranty, expressed or implies exists beyond that included in this statement.
Keen Ovens
Model KHTF-600
Specifications
Capacity 600 lbs. flux
Volts 240 V
W atts 2000 W
The rmostat Prop o rtion al - In terg rate d
Temperature 0ºF-999ºF
Insula tion 4"
Exterior Dimensions 24" X 24" X 64" sloped bottom
Net W eight 250 lbs.
Shipping W eight 283 lbs.
Shipping Dimensions 36" X 30" X 70"
* 480V Single Phase Available
Recommended Spare Parts
When it is critical to have continuous operation of this unit;
we suggest having the following spare parts on hand:
240 V –1 Set of Elements, 1 Contactor
480 V – 1 Set of Elements, 1 Contactor, 1 Transformer
General Information
The KHTF-600 is the most energy efficient flux oven on the market, using onethird the electricity and one half the stabilizing time. The bottom unloading design and
slide valve allows for easy dispensing of flux. The unit is made from steel, treated, and
then painted with a chemical resistant blue finish. All Keen ovens are Mercury free.
Safety Precautions
Read all instructions completely before attempting to operate this unit.
*** SAVE THESE SAFETY INSTRUCTIONS ***
To reduce the risk of electrical shock, fire, or personal injury follow the guidelines below:
• Before connecting unit to a power source, be sure the voltage supplied is the same as that specified on
the name plate of the unit.
• Check outlet to ensure proper grounding of the electrical cable. Have a licensed electrician check the
A/C power outlet if you are not sure.
• Use this unit for its intended purpose as described by literature.
• Make sure power cord is located so that it will not be stepped on, tripped over, or otherwise subjected
to stress of heat, oil, or sharp edges. Do not close doors on the cord.
• To reduce the risk of damage to the electric plug and cord, disconnect by plug rather than by the cord.
• Do not use this unit if cord or plug is in poor condition. If it has been exposed to weather or immersed
in water, have a qualified serviceman inspect and replace parts as necessary.
• WARNING! NEVER HANDLE PLUG, CORD, OR UNIT WITH WET HANDS OR WHILE
STANDING IN WATER.