Henkel 97050, 97051 User Manual

Operating Manual Bedienungsanleitung
UVA Hand Lamp UVA Handlampe
97050/97051

Content

1 Please observe the following............................................................3
1.1 Emphasized Sections ..........................................................................3
1.2 Items Supplied.....................................................................................3
1.3 For Your Safety....................................................................................3
1.4 Field of Application (Intended Use)......................................................3
2 Description.........................................................................................4
3 Technical Data....................................................................................4
4 Installation and Operation.................................................................5
4.1 Installation............................................................................................5
4.2 Operation.............................................................................................5
4.3 Positioning ...........................................................................................5
5 Care, Maintenance, Disposal ............................................................6
5.1 Care.....................................................................................................6
5.2 Maintenance ........................................................................................6
5.3 Disposal...............................................................................................6
7 Annex..................................................................................................6
7.1 Spare Parts..........................................................................................6
2
7.2 CE Declaration of Conformity...............................................................7

1 Please observe the following

1.1 Emphasized Sections
1.2 Items Supplied
1.3 For Your Safety
UV
Warning! Refers to safety regulations and requires safety measures that protect the operator or other persons from injury or danger to life.
– UVA Hand Lamp with ballast/wall power supply 97050 (UK version
97051)
– Operating Manual
As a result of technical development, the illustrations and descriptions in
this operating manual can deviate in detail from the actual unit delivered.
For safe and successful operation of the unit, read these instructions completely. The manufacturer cannot be held responsible for damage or injury of any kind because of misuse or improper application or because of failure to observe safety instructions or warnings.
Be sure to retain this manual for future reference. Get a technical data sheet for the LOCTITE product used at
www.loctite.com.
Use the lamp only in dry locations where no explosion hazard exists. Switch off after use. Only an authorized service center representative, except changing
the bulb, may repair the unit. Damage to the power cord or the housing can result in contact with
live electrical parts. Check the power cord and the unit before each use.
If the power cord or the unit is damaged, do not operate! Replace a damaged power cord with a new one.
Observe general safety regulations for the handling of chemicals! Observe manufacturer’s instructions! Request a safety data sheet for the LOCTITE-product used !
The UVA Hand Lamp generates intensive UV radiation that, with direct exposure, can damage skin and eyes in a short time.
Avoid direct radiation of the skin and eyes under all circumstances!
UV
UV
Wear UV protective glasses and protective gloves in all cases!
1.4 Field of Application (Intended Use)
Special lamp for mobile use, for curing UV and light curable adhesives and
coatings. Because of low intensity, tack-free surfaces cannot be achieved in most cases. Use only in dry locations where no explosion hazard exists!
3

2 Description

1
1
Wall Power Supply with Ballast
2
Hand Lamp
3
Reflector
4
Stand

3 Technical Data

Power Supply 230 VAC, 50 Hz Current Consumption 0.17 A Classification II Protection Class IP 20 Warm-up Time of UV Lamp 3 min Lamp Power 9 W
Lamp Voltage 60V
Emission Spectrum 350-400 nm
Max. Emission 370 nm
Lamp Lifetime Up to 3,000 hours, depending on duty cycle
Intensity ~ 10 mW/cm² at a distance bulb - wetted
component of 20 mm (0.8 inch) Dimensions (L x W x H): 210 x 50 x 40 mm (8.3” x 2” x 1.6”) Length Connection Cord ~ 5 m (~16 ft) Operating Temperature + 15 °C ... + 30 °C (+ 60 °F ... + 86 °F) Storage Temperature - 20 °C ... + 70 °C (- 4 °F ... + 160 °F) Weight UV Lamp complete: 900 g,
Hand Lamp: 170 g
4

4 Installation and Operation

4.1 Installation
Before putting the lamp into operation, check to make sure that nameplate
voltage and frequency agree with power supply.
Power Supply
The Hand Lamp is supplied with ballast unit in mains plug.
Be sure to connect the Hand Lamp into an outlet, which complies with the unit’s protection class limits.
4.2 Operation
The Hand Lamp does not have a switch.
Plug the ballast unit into the socket (230 VAC, 50 Hz) to actuate the lamp. Disconnect the ballast unit to deactivate the lamp.
4.3 Positioning
The UVA Hand Lamp generates intensive UV radiation that, with
UV
direct exposure, can damage skin and eyes in a short time.
Avoid direct radiation of the skin and eyes under all circumstances!
UV
UV
Wear UV protective glasses and protective gloves in all cases!
The lamp is designed for hand-held operation.
For hands-free operation, it may also be set down, or the attached stand 4
can be used for positioning or for suspending it above bench or tabletops. Take care to run the cord in a way to avoid any damage. Use the lamp only for curing UV and light curable adhesives and coatings.
Be sure to follow the adhesive manufacturer’s instructions for use.
Request a Technical Data Sheet for the adhesive to be cured!
Distance to the Wetted Component
Position the Hand Lamp as close as possible to the bond area.
Time to Cure
Depending on the type of adhesive involved, curing may take severa l
minutes. Please refer also to the relevant Technical Data Sheet.