Hengx HAW-3000, HAW-15K, HAW-30K, 1530, 3075 User Manual

...
1、INTRODUCTION ------------------------------------------------- 1 2、ASSEMBLY ------------------------------------------------- 1 3、INSTALLATION ------------------------------------------------- 1 4、PRECAUTION ------------------------------------------------- 1 5、FEATURES ------------------------------------------------- 2 6、AVAILABLE UNITS ------------------------------------------------- 2 7、PANEL AND KEYPAD DEFINITION ------------------------------------------------- 2
7. 1 FUNCTION SETTING ------------------------------------------------- 4
7. 2 PARAMETER SETTING ------------------------------------------------- 4 BACKLIGHT SETTING ------------------------------------------------- 4 RESOLUTION SETTING ------------------------------------------------- 4 FILTER SETTING ------------------------------------------------- 5 ZERO BAND SETTING ------------------------------------------------- 5 BAND RATE SETTING ------------------------------------------------- 5 BUZZER SETTING ------------------------------------------------- 5 CHECK-WEIGHING MODE SETTING ------------------------------------------------- 6 CHECK-WEIGHING MEMORY SETTING ------------------------------------------------- 6 RS232 OUTPUT FORMAT SETTING ------------------------------------------------- 6 EXTERNAL DEVICE SETTING ------------------------------------------------- 7 AUTO TARE SETTING ------------------------------------------------- 7
RS232 OUTPUT CONTENT SETTING
------------------------------------------------- 7
RS232 OUTPUT CONTENT SETTING
------------------------------------------------- 7 UNITS SETTING ------------------------------------------------- 7 INITIAL UNIT SETTING ------------------------------------------------- 8 8、KEYPAD ------------------------------------------------- 8 ZERO ------------------------------------------------- 8 TARE ------------------------------------------------- 8 PRE-TARE ------------------------------------------------- 9 0~9 AND ● ------------------------------------------------- 9 IMPUT ELIMINATE ------------------------------------------------- 9 WEIGHING FUNCTION CONVERSION ------------------------------------------------- 10 UNITS CONVERSION ------------------------------------------------- 10 SAMPLE IN PCS AND % MODE ------------------------------------------------- 10 PRINT ------------------------------------------------- 10 RETURN ------------------------------------------------- 10 NET AND TOTAL WEIGHT CONVERSION ------------------------------------------------- 10 ACCUMULATE ------------------------------------------------- 11 ACCUMULATE DISPLAY ------------------------------------------------- 12 ACCUMULATION ELIMINATE ------------------------------------------------- 13 CHECK-WEIGHING ------------------------------------------------- 14 AUTO TARE ------------------------------------------------- 14 9、 CALIBRATION OPERATION ------------------------------------------------- 15
9.1 CALIBRATION(six point calibration) ------------------------------------------------- 15
9.2 SINGLE POINT CALIBRATION ------------------------------------------------- 16 10、INTERNAL COUNT DISPLAY,TESTING ------------------------------------------------- 17 11、RTC ------------------------------------------------- 18 RTC TIME DISPLAY ------------------------------------------------- 19 RTC TIME SETTING ------------------------------------------------- 20 12、ERROR MESSAGE ------------------------------------------------- 21
12.1 ERROU MESSAGE ------------------------------------------------- 21
12.2 TROUBLE SHOOTING ------------------------------------------------- 21 13、SPECIFICATIONS ------------------------------------------------- 21 (normal type) ------------------------------------------------- 21 (high resolution and filter type) ------------------------------------------------- 22 14、RS-232 OUTPUT FORMAT ------------------------------------------------- 22
-1 -
1、INTRODUCTION:---
Thank your for your purchase of a Hengx high resolution electronic scale. This scale enables you to measure the
quality and weight. The scale is easy to operate, precise, stable and with fast display reaction. It is applicable in the
electronic, hardware, plastic, medicine, textile and various other industries. It is useful for packaging, inventory and
various production and quality control cases.
2、ASSEMBLY:---
3、INSTALLATION:---
z Assembly(please follow the sequence) z Release and remove the protection screw【6】to resist the bottom housing。
z Always lock the protection screw before transportation z 1Power switch z 2RS-232 uni-direction z 3RS-232 bi-direction z 4DC power connector z 5RELAY check-weighing (output)
4、PRECAUTION:---
1 full charge the battery after unpacking the scale. 2 recharge the battery: when battery symbol appears on the LCD display, please plug in the power lord to charge the
battery. The indicator of charge will light up in red. When it becomes green means charge completed( it takes about
8hours to full recharge the battery)*.
3 install the equipment on a level and stable surface. 4 do not install the equipment near the air condition or a vibrating machine. 5 Please in the temperature of 0 ~ 40℃℃,prevent from rapid temperature changes. 6 independent AC outlet for this equipment is recommended, check the voltage before plug in. 7 warm up the equipment for 15 minutes before use.
- 2 -
5、FEATURES:---
1) Load Cell have OIML approved, R60 test
2) the microprocessor in this scale features
A. automatic zero point tracking function
B. tare, pre-tare and auto tare function
C. ACAI function is applicable for the accuracy of unit weight
D. weight HI/LOW setting
E. MAX accumulation (10sets)
F. Each accumulation value print
G. Total accumulation value print
H. BACKLIGHT AUTO ON
I. 2 sets of RS-232 (option)
J. Relay output (option) K. Mini printer(option)
L. RTC( option)
3) clear LCD display, with 22mm digits
4) backlight function
5) over load and transportation protection
6) membrane keypadeasy operation and nice water-resistant function
7) can be used as simple counting scale
8) stainless steel weighing pan
6、AVAILABLE UNITS:---
1) 1 kg = 1000g
2) 1 lb = 453.59237g
3) 1 oz = 28.349523125g
4) PCS
5) %
7、PANEL AND KEYPAD DEFINITION: ---
627
10
34 85
21
9
2019
18
22
1
16
14 11
15
17
1213
-3 -
keypad
1
Press “accumulation” to accumulate(totally 10 times)
(HI used for check-weighing)
8
To come into zero
2
Press this key to enter accumulation
display function,(LO used for
check-weighing)
9
For print
( used to check in unit weight warning and accumulation memory function)
3
Press this key to clear accumulation value
(OK used for check-weighing)
1 0
Units conversion
4
To clear the input data 11
Weighing mode conversion
5
When some weight on the pan, Press “tare” to tare
1 2
Net weight/ total weight conversion
6
For pre-tare
(used to check in accumulation display
and eliminate)
1 3
Return
7
Put samples onto the pan, and input the
number, then press “sample”
1 4
Press to enter weight, quantity and HI/LO/OK check-weighing setting
1 5
~ &
Used for inputting number data
Panel illuminate
1 6
Display weight
1 7
Level instruction
1 8
Recharge instruction
1 9
Check-weighing bigger than instruction
2 0
Check-weighing equals with instruction
2 1
Check-weighing smaller than instruction
2 2
Enter accumulation
- 4 -
7.1 FUNCTION SETTING:---
KEYPAD FUNCTION
NO/OFF +
Parameter setting
NO/OFF + +
display COUNT(OFFSET)
NO/OFF + + +
weighing mode
NO/OFF +
Linearity calibration
NO/OFF +
Single point calibration RTC on/off, display and setting
NO/OFF + +
Initialization setting
7.2 PARAMETER SETTING:(underline words are initial setting) ---
OPERATION LCD display
press to switch on
Backlight setting--
press z on / off / auto (“on” means the backlight is always be light; “off” means the backlight is turn down; “auto” means the backlight will on when there is weight on it.)
press to change the setting
Resolution setting--
press z 1 (15000 dual display resolution)
2 (3000 or 3750)
3 (6000 or 7500) 4 (15000)
(normal type)
z 2 (3000 or 3750) 3 (6000 or 7500)
4 (15000)
5 (30000)
(high resolution and filter type)
press to select in turn
-5 -
Filter setting--
press z F1 / F2 / F4 / F8
(higher value, higher filter grade)
press to select in turn
Zero band setting--
press z d0 / d1 / d2 / d3 / d4 / d5
(more bigger means auto zero Tracking more bigger)
press to select in turn
Band rate setting--
press
z band rate setting: 9600
Buzzer setting--
press z on(buzzer on) / oFF(buzzer off)
press to select in turn
- 6 -
Check-weighing mode setting:--
press z HI(upper )/ Lo(lower)/ In(during
upper value to lower value) /un ( outside the value)/ 3b( 3 point)/ oK( 1 point) /oFF(close)
z (totally we have 3 value to set. For
example, if you set 3kg for HI, and 1kg for LO, and 2kg for OK, then if you want it warning when upper than 3kg, then you choose HI, if you want it warning when lower than 1kg, then you choose LO, if you want it warning when during 1kg-3kg, then you choose IN, if you want it warning when upper than 3kg and lower than 1kg, then you choose Un, if you want it warning just in 3kg, 2kg, and 1kg, then you choose 3b, if you want it warning in 2kg, then you choose OK, if you do want any warning, then you choose OFF.)
press to select in turn
Check-weighing memory setting--
press z M.On / M.oFF
(“M.On” means check-weighing memory is open; “M.oFF” means check-weighing memory is closed)
press to select in turn
press and to eliminate check-weighing
RS232 output format setting--
press z Prt.Pr -data sent when key
Pressed(can do date send in dual direction, see page 22)
z Prt.Co- data sent continuously z Prt.St-data sent auto matically when
stable symbol show
press to select in turn
-7 -
External device setting--
press z PC / SH / TDP/ SCR(“PC” means
connect to computer; “SH” means connect to matrix printer; “TDP” means connect to thermal printer; “SCR” means connect to large screen.)
press to select in turn
Auto- tare setting--
press z YES(on) / NO(off)
press to select in turn
RS232 output content setting (net weight)--
press z Pr(print/ nPnot print
press to select in turn
RS232 output content setting (accumulation value)--
press z Pr(print/ nPnot print
press to select in turn
Units setting
press then press
press and on/off setting in turn
press back to parameter setting
- 8 -
Initial unit setting--
press z units
press to select in turn
press back to normal weighing mode
8、KEYPAD:---
ZERO--
z press
tare--
z
z press z tare can’t operate below zero or
above max capacity
-9 -
Pre-tare--
press
z press ~ and to
input pre-tare value
z press z tare condition: zero symbol should
display on
0~9 and ●:--
z ~ and z to load the pre-tare value and
check-weighing
Imput eliminate--
z press z in the pre-tare, check-weighing
mode
- 10 -
Weighing function conversion--
z press z used for weighing, pcs and % mode
Units conversion:
z press z for units conversion
Sample in PCS and % mode--
z in PCS and % mode
z press ~ and
z put on object
z press to sample
print:--
Condition of printing:must be stable. press printing LCD display value.
return--
press return to weighing mode
Net and total weight conversion--
press net and total weight conversion
-11 -
accumulate:--
z
z press perform accumulation z accumulation conditionin the stable
conditon; only can accumulate once, remove objects on the pan and could accumulate once more; totally can accumulate for ten times.
z 1 sec later return to normal weighing
mode
z when accumulating more than 10
times
z means: times of accumulation over
range, 1sec later return to normal weighing mode
- 12 -
Accumulate display:--
z press ,perform accumulating
display
z press ~ or or to select accumulation time
z press z means: accumulate the first
accumulation and quantities of individual accumulation
z press z meanstotal weight accumulation,
times of accumulation and quantities of accumulation
z press back to normal
weighing mode
z when total value of accumulation
over display range, it will show
press to get the accumulation value
-13 -
Accumulation eliminate:--
z press to carry out
accumulation
z press ~ or or to select time of accumulation
z press z meansaccumulate value of the first
time and individual quantities.
z press to cancel the
accumulation value
z press z means total weight, times and
quantities of accumulation
z press to cancel the
accumulation value
z press back to normal
weighing mode
z press to get accumulation
value.
- 14 -
Check-weighing--
z press
z press to select
the check-weighing value
z select check-weighing condition then press ~ and to load check-weighing range
z press to confirm the loading of check-weighing range
z then press back to normal weighing mode, when check-weighing wrong, it will show
z press to cancel check-weighing and back to normal weighing mode
Auto-tare--
z auto-tare condition: cann’t work below zero or above max
capacity. In the stable condition, max≥2%
z Can not tare constantly (after auto tare, press “tare” to
cancel pre-tare and get new tare value)
z if need another auto tare, clear the pan, press “zero” or
“tare” to re-tare.
-15 -
9、CALIBRATION OPERATION:---
9.1 calibration(six point calibration
--
operation LCD display
z press to switch on the
machine.
z press z zero point calibration
z waiting
z place 1/6 of load on press to perform 1/6 load calibration
z waiting
z place 2/6 of load onpress to perform 2/6 load calibration
z waiting
z place 3/6 of load onpress to perform 3/6 load calibration
z waiting
z place 4/6 of load onpress to perform 4/6 load calibration
- 16 -
z waiting
z place 5/6 of load onpress to perform 5/6 load calibration
z waiting
z place full load onpress to perform full load calibration
z waiting
z press to return normal weighing mode
9.2 single point calibration:--
operation LCD display
z press to switch on the
machine
z press
z press
z place poise of equivalent weight
-17 -
z waiting for judging the weight
z waiting
z press
z press back to normal
weighing mode
10、COUNT DISPLAY,testing:---
operation LCD display
z press to switch on the
machine
z press z then press any other key, display
total weight
z press display offset value
z press back to normal weighing mode
- 18 -
11、RTC:--
z press to switch on the
machine
z press
z press
z press to chooseon(with RTC)/oFF( without RTC)
z press
z press back to normal
weighing mode
-19 -
RTC time display:--
operation LCD display
z press to switch on the
machine
z press
z press
z press to display on turn
z press
z press back to normal weighing mode
- 20 -
RTC time setting::--
operation LCD display
z press to switch on the
machine
z press
z press
z press to display in turn
z press ~ from let to right
to load time, press to
confirm
z press
z press back to normal weighing mode
-21 -
12、ERROR MESSAGE:---
12.1、 errou message:
message problem
Err5
Over loadmax capacity +9e
ACC.ov Times of accumulation over 10 times
over Display value over range
Battery symbol Low battery
12.2、trouble shooting:---
when Error message Trouble shooting
Power on Battery symbol appear Charge the battery
Normal weighing mode Err5 Check if weighing object over the capacity +9e,Err
13、specifications:---
(normal type)
mode
1530 3075 7515 1530K
Max. Cap
0g~1500g 1500g~3000g 0g~3000g 3000g~7500g 0g~7500g 7500g~15000g 0g~15000g 15000g~30000g
Resolution kg
0.0001kg 0.0002kg 0.0002kg 0.0005kg 0.0005kg 0.001kg 0.001kg 0.002kg
Resolution g
0.1g 0.2g 0.2g 0.5g 0.5g 1g 1g 2g
Linearity
±2d ±2d ±2d ±2d
Repeatability
0.1g 0.2g 0.2g 0.5g 0.5g 1g 1g 2g
Internal resolution
0.01g 0.02g 0.05g 0.1
LCD LCD Display LED backlight 6 1/2 DigitsWith 24.5 mm digits
dimension
300X320 cm
pan
300X200 cm
adaptor DC12V 300mA Adaptor6V4A rechargeable battery
resolution 1/7,500 1/6,000
Keypad
25 key
Protect device
Over load and transportation protect
Wind shields
yes
Function
Check-weighing, weight accumulation(10times) Pre-tarelinearity calibration,six point 1/6 max2/6 max3/6 max4/6 max5/6 max、max) Soft-ware filtering, units conversion, printing setting, auto average
temperature
0°c~40°c
RS-232 Bi-direction and dual-direction, could connect PC、SH-24TDP-643 printer、SCR
RELAY
HI LO OK RELAY output module
- 22 -
(high resolution and filter type)
mode
3000 7500 15K 30K
Max. Cap
0g~3000g 0g~7500g 0g~15000g 0g~30000g
Resolution kg
0.0001kg 0.0002kg 0.0005kg 0.001kg
Resolution g
0.1g 0.2g 0.5g 1g
Linearity
±2d ±2d ±2d ±2d
Repeatability
0.1g 0.2g 0.5g 1g
LCD LCD Display LED backlight 6 1/2 Digits With 24.5 mm digits
dimension
300X320 cm
pan
300X200 cm
adaptor DC12V 300mA Adaptor6V4A rechargeable bettery
resolution 1/15,000
Keypad
25 key
Protect device
Over load and transportation protect
Wind shields
yes
function
Check-weighing weight accumulation (10 times) Pre-tare, linearity calibration( six point, 1/6 max2/6 max3/6 max4/6 max5/6 maxmax)
soft-ware filteringunits conversion, printer setting and auto average
temperature
0°c~40°c
RS-232 Bi-direction and dual-direction、can connect with PC、SH-24TDP-643 printer、SCR
RELAY
HI LO OK RELAY output
bi-direction RS-232 interface
14、RS-232 output format:---
Remarks for Dual output:1. data can be sent in dual direction when you choose Prt.Pr,
2. it equals with pressing when computer send “Z”to scale;
it equals with pressing when computer send “T”to scale;
it equals with pressing when computer send “R”to scale;
SCALE
單向
DSUB9
5
9
4
8
3
7
2
6
1
SCALE
雙向
DSUB9
5
9
4
8
3
7
2
6
1
TXD1
RXD1
GND
TXD2
GND
BI-DIRECTION DSUB9
UNI-DIRECTION DSUB9
-23 -
RS-232 serial interface
The 9PIN interface in the right back is the standard interface of RS-232, 3rd PIN is output, 5th PIN is groundedthe rest is
useless.
BAUD RATE9600 bps DATA BIT8 PARITY BITNONNE﹞ STOP BIT1 CODEASCII BIT FORMAT
LSB MSB 0 1 2 3 4 5 6 7
START BIT DATA BIT STOP BIT
DATA FORMAT:(Prt.Co)
N W : +/- k g CPLF T W : +/- k g CPLF G W : +/- k g CPLF
e.g.
N.W.: 1.000 kg T.W.: 0.050 kg G.W.: 1.050 kg
DATA FORMAT:(Prt.Co)
N W : +/- g CPLF T W : +/- g CPLF G W : +/- g CPLF
e.g.
N.W.: 1000 g T.W.: 50 g G.W.: 1050 g
DATA FORMAT:(Prt.Co)
N W : +/- l b CPLF T W : +/- l b CPLF G W : +/- l b CPLF
e.g.
N.W.: 1.000 lb T.W.: 0.050 lb G.W.: 1.050 lb
DATA FORMAT:(Prt.Co)
N W : +/- o z CPLF T W : +/- o z CPLF G W : +/- o z CPLF
e.g.
N.W.: 1.000 oz T.W.: 0.050 oz G.W.: 1.050 oz
DATA FORMAT:(Prt.Co)
N W : +/- T - J i n g CP LF T W : +/- T - J i n g CP LF G W : +/- T - J i n g CP LF
e.g.
N.W.: 1.000 T-Jing T.W.: 0.050 T-Jing G.W.: 1.050 T-Jing
- 24 -
DATA FORMAT:(Prt.Co)
N W : +/- H - J i n g CP LF T W : +/- H - J i n g CP LF G W : +/- H - J i n g CP LF
e.g.
N.W.: 1.000 H-Jing T.W.: 0.050 H-Jing G.W.: 1.050 H-Jing
DATA FORMAT:(Prt.Co)
N W : +/- t l . t CP LF T W : +/- t l . t CP LF G W : +/- t l . t CP LF
e.g.
N.W.: 1.000 tl.t T.W.: 0.050 tl.t G.W.: 1.050 tl.t
DATA FORMAT:(Prt.Co)
N W : +/- t l . H CP LF T W : +/- t l . H CP LF G W : +/- t l . H CP LF
e.g.
N.W.: 1.000 tl.H T.W.: 0.050 tl.H G.W.: 1.050 tl.H
DATA FORMAT:(Prt.Co)
N W : +/- P C S CPLF T W : +/- P C S CPLF G W : +/- P C S CPLF
e.g.
N.W.: 1000 PCS T.W.: 50 PCS G.W.: 1050 PCS
DATA FORMAT:(Prt.Co)
N W : +/- % CPLF T W : +/- % CPLF G W : +/- % CPLF
e.g.
N.W.: 1000 % T.W.: 50 % G.W.: 1050 %
DATA FORMAT(Prt.St Prt.Pr)
A c c ● X X N W : +/- X X X X X X CP LF A c c ● A l l X X N W : +/- X X X X X X CP LF
e.g.
HAWXXXX N/S:XXXXXX Acc.01 N..W.: 1.000 XX Acc.ALL01 N..W.: 1.000 XX
Loading...