USING.
Before you start to install and use the sauna heater check the following:
- that you have got all the parts needed.
- check that the voltage of the heater and the control box is the right one and that the
control box suits your heater.
- chech that the effect of the heater suits your sauna. You must not exceed or go be low the volumes mentioned in table 1.
- look at the installation distances in table. 1. You have to follow these, otherwise it can
cause a burn.
- study these installation- and using instructions carefully.
HOW TO CHOOSE THE EFFECT OF THE HEATER.
Noticing the volume of the sauna you choose the effect of the heater according to
table 1.
The volumes mentioned in table 1 are valid under the assumption that the sauna is
well insulated. If there are walls of bricks or concrete in the sauna you have to add to
the volume about 1,2m2 for every brick- or concerete wall m3 and then you choose the
effect of the heater according to the composed volumes.
MOUNTING OF THE SAUNA HEATER
The sauna heaters are freestanding models and these heaters must be firmly fastened
to the floor by screwbolts through two of the feet. When fastening the heater to the
floor please follow the requirements about the minimum distances to combustible material indicated on the name plate of the heater and in table 1 and fig. 1. The sauna
heater can be placed on a wooden floor. Do not protect the wall behind the heater with
for instance asbest- or eternite plates, as these may cause a too high temperature
increase in the wall.
Do not place the sauna heater in a nisch, and you must not have a compact quard rail
around the heater. Draught from door, vents etc. should be avoided as this effects the
thermostat.
QUARD RAIL
If you put a quard rail around the heater you have to note the minimum distances
mentioned in table 1.
MOUNTING OF THE CONTROL BOX
The control box must be installed in a dry place outside the sauna room. The sensor
unit should be fastened to the wall in the sauna according to fig 1. please follow the
measurements mentioned in fig 1. otherwise it may cause a burn.
TABLE 1.
HEATER SAUNA MINIMUM DISTANCES CABLES TO FUSES CONTROL
Type Effect Volume Height From heater to Control Sensor Steamy Main PANEL
Min. Max Min panel unit unit fuse
side- cei- quard rail HO7BB and ling and upper F5G
bench
Hmin A min B min C min
kW m m mm mm mm mm mm mm mm A
1105-.. 9,0 8 12 1900 80 1200 80 6 x 1,5 4 x 0,5 5 x 2,5 16 X
1105-.. 10,5 9 15 1900 80 1200 80 6 x 1,5 4 x 0,5 5 x 2,5 16 X
1105-.. 12,0 10 18 2100 120 1400 120 6 x 1,5 4 x 0,5 5 x 4 20 X
1105-.. 15,0 14 24 2100 120 1400 120 6 x 1,5 4 x 0,5 5 x 6 25 X
backwall
0518-2-151704