TDDGT - Instruction Manual
7-Day Digital Geyser Timer (Internal Relay)
Rated Voltage: 220-240V AC |
Max 20A |
(3500 Watts) |
||
|
16 Programmable Settings |
|
Resistive Load (Geyser) |
|
|
15-Day Backup Battery |
|
Max 10A |
(Inductive Load) |
|
IEC 60730 Rated |
|
DIN Rail Mounted |
Operating Instructions
Apply 220V to Live (L) terminal and Neutral (N) terminal on timer.
Wait for 20 seconds, then push recessed Reset button. Timer will reset.
SETTING DAY & TIME
Push and hold Clock button.
Push D+ repeatedly to adjust Day.
Push H+ repeatedly to adjust Hour.
Push M+ to adjust Minute.
Release Clock button. Time and Date set.
Push Clock button once. Program 1 is now set.
For timer to operate automatically press Manual button until On Auto appears on screen.
To operate timer manually press Manual button until On or Off appears on screen.
RECOMMENDED MUNICIPAL TIME SETTINGS
Timer 1: 04:00 ON – 06:00 OFF
Timer 2: 11:00 ON – 14:00 OFF
Timer 3: 16:00 ON – 18:00 OFF
Timer 4: 21:00 ON – 23:00 OFF
OR
RECOMMENDED POWER UTILITIES TIMES
21:00 ON – 06:00 OFF
PROGRAMMING TIMER |
WIRING |
|
|
Push P button once (Program 1 On appears.) |
Connect 220V to Live (L) terminal and Neutral (N) terminal |
|
|
on timer. |
|
Push D+ repeatedly until desired day is reached (various |
The Load must be connected to the Load terminal. |
|
combinations of days are available). |
|
|
Push H+ repeatedly until desired hour is reached. |
The Load terminal will be LIVE only when timer is on. |
|
Push M+ repeatedly until desired minute is reached. |
The Neutral of the Load must be connected to the |
|
|
appropriate Neutral bar and NOT the timer. |
Push P button once again (Program 1 Off appears).
Push D+ repeatedly until desired day is reached (various combinations of days are available).
Push H+ repeatedly until desired hour is reached.
Push M+ repeatedly until desired minute is reached.
WIRING DIAGRAM |
|
|
|
|
|
|
|
|
|||||
Line In |
|
|
|
|
|
|
|
|
|
|
|
|
Neutral |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
Live In |
|
|||||||||
Geyser |
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
TDDGT |
|
|
||||||
|
|
|
|
|
|
|
|||||||
Circuit |
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
Timer |
|
|
|||||
Breaker |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
Live |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Load Out |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Please note:
All electrical installations should be done by a qualified electrician.
The maximum current rating is 20 Amps.
Resistive loads (geysers, under-floor heating and lights)
Inductive loads (pool pump, air-conditioners).