HellermannTyton TDDGT User Manual

0 (0)
HellermannTyton TDDGT User Manual

TDDGT - Instruction Manual

7-Day Digital Geyser Timer (Internal Relay)

Rated Voltage: 220-240V AC

Max 20A

(3500 Watts)

 

16 Programmable Settings

 

Resistive Load (Geyser)

 

15-Day Backup Battery

 

Max 10A

(Inductive Load)

 

IEC 60730 Rated

 

DIN Rail Mounted

Operating Instructions

Apply 220V to Live (L) terminal and Neutral (N) terminal on timer.

Wait for 20 seconds, then push recessed Reset button. Timer will reset.

SETTING DAY & TIME

Push and hold Clock button.

Push D+ repeatedly to adjust Day.

Push H+ repeatedly to adjust Hour.

Push M+ to adjust Minute.

Release Clock button. Time and Date set.

Push Clock button once. Program 1 is now set.

For timer to operate automatically press Manual button until On Auto appears on screen.

To operate timer manually press Manual button until On or Off appears on screen.

RECOMMENDED MUNICIPAL TIME SETTINGS

Timer 1: 04:00 ON – 06:00 OFF

Timer 2: 11:00 ON – 14:00 OFF

Timer 3: 16:00 ON – 18:00 OFF

Timer 4: 21:00 ON – 23:00 OFF

OR

RECOMMENDED POWER UTILITIES TIMES

21:00 ON – 06:00 OFF

PROGRAMMING TIMER

WIRING

 

Push P button once (Program 1 On appears.)

Connect 220V to Live (L) terminal and Neutral (N) terminal

 

 

on timer.

 

Push D+ repeatedly until desired day is reached (various

The Load must be connected to the Load terminal.

 

combinations of days are available).

 

 

Push H+ repeatedly until desired hour is reached.

The Load terminal will be LIVE only when timer is on.

 

Push M+ repeatedly until desired minute is reached.

The Neutral of the Load must be connected to the

 

 

appropriate Neutral bar and NOT the timer.

Push P button once again (Program 1 Off appears).

Push D+ repeatedly until desired day is reached (various combinations of days are available).

Push H+ repeatedly until desired hour is reached.

Push M+ repeatedly until desired minute is reached.

WIRING DIAGRAM

 

 

 

 

 

 

 

 

Line In

 

 

 

 

 

 

 

 

 

 

 

 

Neutral

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Live In

 

Geyser

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TDDGT

 

 

 

 

 

 

 

 

 

Circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer

 

 

Breaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Live

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Load Out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please note:

All electrical installations should be done by a qualified electrician.

The maximum current rating is 20 Amps.

Resistive loads (geysers, under-floor heating and lights)

Inductive loads (pool pump, air-conditioners).