Heiman 2 BEAMS, ABT-20, ABT-30, ABT-40, ABT-60 Installation Manual

...
ABT 2 BEAMS ACTIVE PHOTOELECTRIC DETECTOR WITH DIGITAL FREQUENCY COVNVERSION
INSTALLATION GUIDE
1
On working mode(non-programming mode),
signal strength indicator. Open signal indicator
when adjusting,after that ,close indicator for
saving power .
Switch
Tra/Rec
DIP1
DIP2
DIP3
DIP4
DIP5
Frequency switch
No
No
Buzzer switch
POWER DC13.8V-24V(NON-POLAR)
ABT-
TRANSMITTER
MODEL
LOT.
POWER
MODEL
POWER DC13.8V-24V(NON-POLAR)
ABT-
RECEIVER
LOT.
POWER
123
45
LH
ALARM
Power indicator
Power supply
Alarm
Test hole
Signal strength indication
State
. Parts Name
Housing
Vertical fine-tune knob
Wiring terminal
Tamper switch
Indicator
Lens
Voltage test hole
Response time Adjustment knob
Receiving box
Housing locking screw
Viewfinder
Bracket
Collimation hole
Grade
On on o n on on G 1 0 On on on on twinkle G 9 Off o n on on o n G 8 Off on on on twinkle G 7 Off o ff on on on G 6 Off off on on twinkle G 5 Off off off on on G4 Off off off on twinkle G 3 Off o ff off off on G 2 Off off off off twinkle G1 Off off off off off G0
Signal strength indication (11 grades) Suggested over 7 grades
Signal strength indication
(LED5-LED1)
Technical parameters:
Model ABT-20
20m
60m
ABT-30
30m
60m
ABT-40
40m
120m
ABT-60
60m
180m
ABT-80
80m
240m
ABT-100
100m
300m
No. of beams
Detection mode
Optical source
Response speed
Alarm output
Power supply
Operation temperature & humidity
Dimensions
Tamper output
Optical axis adjustment(H)
Optical axis adjustment(V)
Protection against dew, frost
Material
Net weight
Gross
Alert distance
Outdoor
Indoor
Calefaction housing (optional)
PC resin
658g(receiver +transmitter)
1150g
2 beams
2 beams blocked simultaneous
Infrared digital pulse beam
Relay contact output: NO. NC contact rating: AC/DC30V 30AMax
Contact output: NC contact rating DC24V 0.5Amax
Refer to its diagram
20(10)
50-240ms
DC13.8-24V 15W
RECEIVER
TRANSMITTER
-25-55 5-95%RH (relative humidity)
180 ( 90 )
No
2
50mm
50mm
. Precautions for setting
Impediment presents during setup
receiver
transmitter
receiver
transmitter Multi sensors may be used for long-distance guarding. Please install according to the below diagram to avoid interference between beams.
The base is unstable
receiver
transmitter
transmitter
receiver
Horizontal 180 ( 90 )
Vertical 10
Direct sunlight, lamplight etc.
Detection distance
Beam spread diameter
Style
ABT-20 ABT-30 ABT-40 ABT-60 ABT-80
ABT-100
Guarding distance
Beam spread diameter
20m 30m 40m 60m 80m
100m
0.6m
0.7m
1.0m
1.5m
1.8m
2.1m
Loading...