KEY BUTTONS
On the back of the HEDLER Profilux® LED
1000
T there are several key buttons. By pressing them the indicated functions will be switched
alternatingly.
Fan 100% / Automatic
100% - the fan cooling of the HEDLER Profilux® LED
1000
T will be set to full power irrespective of the operating temperature;
Automatic - the power of the fan cooling will be regulated as a function of the operating temperature
Dimmer OFF / ON
OFF - the continuous light output power is set to maximum (100%), the setting of the rotary potentiometer will be ignored;
ON - dimming function is available by turning the rotary potentiometer
POWER OFF / ON
OFF - light unit will be switched off or rather into stand-by-mode (if the light unit has to be currentless you have to disconnect the light unit from
the electric power supply);
ON - light unit will be switched on with a Softstart function, the pre-set continuous light output power will be restored
If not in use, please disconnect the light unit from the power supply completely.
STATUS-LEDs
Additionally you will find on the back of the HEDLER Profilux® LED
1000
T several status LEDs. Their operation mode will be indicated by their
glowing or blinking.
Error
Indicates an operating mode error of the HEDLER Profilux® LED
1000
T. In this case the light unit has to be checked. Please contact Hedler
Systemlicht GmbH directly or contact your photographic specialized dealer.
info@hedler.com
0049 (0) 6482-918100
Please note:
If the light unit will be disconnected from the electric power supply the Error LED is glowing until the mains adapter is discharged. This is not
indicating an error.
Service
A blinking of this LED indicates that the HEDLER Profilux® LED
1000
light unit model was in operation for 6000 hours. The light unit should be
send to Hedler Systemlicht GmbH for recalibration. Please contact Hedler Systemlicht GmbH directly or contact your photographic specialized
dealer.
info@hedler.com
0049 (0) 6482-918100
Power
A continuous glowing of this LED indicates the light unit is switched on.
Cooling
A continuous glowing of this LED indicates the fan cooling is working.
LED
The HEDLER Profilux® LED
1000
T is equipped with one 185 W high power single cell LED with 135 lm/W, which can´t be replaced by the user.
If any technical failure of the LED takes place please contact Hedler Systemlicht GmbH or your photographic specialized dealer how to proceed.
info@hedler.com
0049 (0) 6482-918100
HEDLER Systemlicht GmbH Heerstrasse 112 D-65594 Runkel / Lahn www.hedler.com
Telefon + 49 - (0) 6482 918 100 Telefax + 49 - (0) 6482 918 111 eMail info@hedler.com
OPERATION MANUAL
TECHNICAL DATA Profilux® LED
1000
T
Type: Profilux® LED
1000 T
Voltage: 110 - 230 V ~ 1,0A 50/60 Hz Power: 185 W LED Risk group: 0-RG
Color: CRI > 93 Color temperature: 3400K Safety class system: I Protection category: IP30
Weight: 3300g Ambient temperature (Ta): -15° - +40° C Surface temperature: 85°C
Light stand attachment: 5/8“ Fresnel lens code: < 6507 > Light unit code: < 5032 >
Safety clearance: Position:
Under any circumstances do not under-run the safety Tilt light unit max.
clearances given within the graphic to inflammable material! 45° upwards/down-
wards in operation!