Heatstore Ultima Profile Eco 2.5, Ultima Profile Eco 5.0, Ultima Profile Eco 7.5 Installation And User Instruction Manual

1
1
ULTIMA PROFILE ECO
Installation and User Instructions
Models: 2.5, 5.0, 7.5 litre
Please read and understand these instructions before starting work.
Please leave this leaflet with the user following installation.
This Boiling Water Heater must only be installed
by qualified persons.
2
INTRODUCTION
Thank you for purchasing a Heatstore Ultima Profile Eco Boiling Water unit. The heater is manufactured to the highest standards and has been designed to meet all the latest relevant safety specifications.
This water heater must be installed (Sections 1-5), commissioned (Section 6) and maintained (Sections 7-8) by a competent person. Please read and understand these instructions prior to installing your Ultima Profile Eco water heater. Following installation and commissioning the operation of the heater should be explained to the user (Section 10) and these instructions left with them for future reference.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
COMPONENT CHECKLIST
Before commencing installation check that all the following components have been supplied with your Ultima Profile Eco water heater.
Wall mounting bracket• No.12 x 2” screws (2 off)• No.8 x 1” screw (1 off)• No.12 x 2” wall plug (2 off)• No.8 x 1” wall plug (1 off)• 15mm x 15mm straight push-fit connector (fitted)• 15mm x 15mm 90 ° elbow push fit connector (fitted)•
3
3
TECHNICAL SPECIFICATION
CONNECTIONS
Inlet connection -15mm ext. diameter Water entry point - bottom and rear Cable entry point - bottom and rear
ELECTRICAL
Model numbers
Heatstore Ultima Profile Eco 2.5ltr ..........................HSBW025ECO
Heatstore Ultima Profile Eco 5.0ltr ..........................HSBW050ECO
Heatstore Ultima Profile Eco 7.5ltr ..........................HSBW075ECO
Electrical rating ....................................................2.3/2.5kW@230/240V
Weight (full) Model 2.5 litre ..............................8.4kg
Model 5.0 litre ...............................11.8kg
Model 7.5 litre ..............................15.4kg
Rated pressure
Minimum supply pressure ......................................0.05MPa (0.5 bar)
Maximum supply pressure .....................................1.0MPa (10 bar)
Enclosure rated ....................................................IP X2
Nominal commissioning times (minutes) to temperature ready
Model 2.5 litre ....................................................16
Model 5.0 litre ....................................................24
Model 7.5 litre ....................................................32
STANDARDS AND APPROVALS
Complies with the requirement of EN 60335-2-35. British Electromechanical Approvals Board (BEAB) approved. Complies with European Community Directives (CE).
4
1.0 IMPORTANT INSTALLATION POINTS
1.1 The Heatstore Ultima Profile Eco stores and dispenses water at or close to boiling point at all times it is switched on. Due caution must be taken when choosing a location for the product to minimise misuse. Locate the unit over a draining board NOT over the sink or basin.
1.2 Push fit connectors DO NOT grip chromed or stainless pipe.
1.3 The Heatstore Ultima Profile Eco is a vented water heater. The vent pipe must never be blocked or obstructed, it must be a minimum of 15mm outside diameter pipe. Where the vent pipe length exceeds 3m the pipe diameter should be increased. The vent pipe must be laid to a continuous fall and discharge in a safe and visible position; it must discharge via a tundish or finish a minimum of 20mm above a draining board. The vent pipe material must be capable of conveying boiling water. The vent pipe must never be connected directly to a soil pipe.
1.4 Wherever possible the Heatstore Ultima Profile Eco should be supplied directly from a rising main. If fed from a cold water feed cistern, the cistern must comply with the Water Regulations Guide (clause R27.2). It should be noted that water quality may be reduced when supplied from a cistern and additional forms of water pretreatment may be necessary.
1.5 In hard water areas, heated water will produce lime scale which will be deposited within the heater. If this is not regularly removed it will impair the operation of the heater. Where rapid and excessive scale build up is likely to occur the use of a proprietary scale reducing device may be beneficial.
1.6 The installation must be carried out in accordance with the relevant requirements of:
The appropriate Building Regulations either The Building Regulations • (England & Wales), The Building Regulations (Scotland) or Building Regulations (Northern Ireland). The Water Supply (Water Fittings) Regulations in England & Wales or • Water Byelaws in Scotland.
1.7 The Heatstore Ultima Profile Eco will adjust for ambient (room) temperatures of between 1°C and 40°C.
1.8 When not in use care must be taken to prevent it freezing; if thought to be frozen it must not be switched on. It must be left to thaw and must then be thoroughly inspected to ensure it is totally thawed and undamaged.
1.9 The unit is not suitable for installation in an area where a water jet could be used.
5
5
2.0 IMPORTANT INSTALLATION POINTS
2.1 The Heatstore Ultima Profile Eco must be vertically wall mounted using the
bracket supplied.
2.2 Fig.1, p6 details the outside dimensions of the unit. It is recommended
that the unit is positioned above the draining board. If this is not possible, consideration should be given to any spillages that may occur under the appliance. The heater should be positioned at a height to suit the items being filled (flasks, pans, cups etc.). This is likely to position the base of the unit 250mm above the work surface.
2.3 Sufficient room should be left around the heater to allow access for
maintenance and servicing. The top should not be covered as this will reduce the efficiency of the unit.
2.4 Ensure that the wall can support the full weight of the unit (see technical
specifications, p3) and that there are no hidden services (electricity, gas or water) below the surface of the wall.
2.5 Using the backplate mark the fixing positions and water and vent entry
points. Drill and plug the fixing positions. Fix the mounting bracket to the wall using the two No. 12 x 2” screws provided (confirm suitability of all screws and plugs for use with the wall, if unsuitable due to wall type provide alternative fixings)
2.6 If rear entry services are to be used the necessary holes for these should be
prepared prior to hanging the unit onto its bracket.
2.7 Remove the front cover by unscrewing the top and bottom cover fixing screws
bottom and top. Hang the unit onto the wall mounting bracket. Secure anchor point to the wall with the No.8 x 1” screw (provided).