Heatstore HSAC3 Operating Instructions Manual

Telephone: 0117 923 5375 Fax: 0117 923 5374 Victoria Road, Avonmouth, Bristol BS11 9DB
www.heatstore.co.uk
IMPORTANT SAFEGUARDS
WHEN USING ANY ELECTRICAL APPLIANCE, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED.
PLEASE READ ALL INSTRUCTIONS CAREFULLY
ISSUE 1: 0616
HSAC3 Air Curtain
Operating Instructions
3kW Air Curtain with ‘half power’ setting
and air circulation mode
HSAC3[16]instructions 9/6/16 09:18 Page 1
Usage and product description
The air curtain is designed to prevent the entry of the cold ambient air into
a building and to reduce the thermal losses inside the premises. The
curtain is designed for the operation in premises with the ambient
temperature of from -10°C to +40°C and the relative humidity up to 80%
(at the temperature +25°C).
The HSAC3 is manufactured from sheet steel coated with a high-quality
polymer. The ‘body’ of the unit contains heating elements, the fan modules
and the control switches. The fans draw in the air through the front
perforated grid of the body (2); the airflow passing through the heating
elements is heated, enters the ventilation assembly and released through
the air-relief nozzle (3) as the directed flow.
The HSAC3 also has a cool air circulation function in addition to ‘full’ and
’half’ power heating functions.
Before Installation
Select a suitable position for installation, allowing free access all around
and no closer than 100mm to the ceiling. For wide doorways, these units
may be mounted end-to-end, but allowing a suitable gap for the mounting
brackets if these are used, and for access and cable entry.
Installation
The HSAC3 may be fixed directly to the surface above an entry or for
greater operational flexibility may be installed using the supplied mounting
brackets. See overleaf for details.
Model covered by these instructions:
HSAC3 – 3kW Air Curtain with ‘half-power’ setting and air circulation
mode
Safety Instructions
• Please read these installation and operating instructions before using the product. Failure to do so may cause injury or void the warranty.
• This Air Curtain is NOT suitable for installation in a hostile environment.
• DO NOT operate the heat curtain in premises with the relative humidity >80%.
• The heater MUST be earthed when installed.
• DO NOT switch on the heater if the covers are removed.
• If the curtain is connected directly to the fixed wiring it must be provided with an automatic circuit breaker or tripping device.
• ALWAYS conform to the general safety rules for electrical devices.
• DO NOT cover the unit and do not limit the air flow at the inlet and outlet,
• DO NOT operate the unit if there is visible damage to the unit or power supply.
• Only a suitable qualified person should install and maintain the unit, otherwise there may be a risk of, electric shock or fire.
• To avoid electric shock disconnect the device from the power mains before starting cleaning or maintaining.
32
Figure 1
Dimensions
L = 585mm
A = 450mm
B = 65mm
C = 30mm
E = 155mm
F = 150mm
HSAC3[16]instructions 9/6/16 09:18 Page 2