NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
OPERATING INSTRUCTIONS
Model #
AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
MH18CH
PORTABLE PROPANE
LANGUAGES INCLUDED
CABINET HEATER
DO NOT LEAVE HEATER UNATTENDED OR IN OPERATION WHILE SLEEPING
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER
CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM
HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR
ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR
SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS INSTRUCTION MANUALS, LABELS,
ETC., CONTACT THE MANUFACTURER.
WARNING:
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES SUCH AS
BUILDING MATERIALS, PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS
RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY
CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE, SOLVENTS,
PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.
•English
•French
•Spanish
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE
27502 MR. HEATER, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
SPECIFICATIONS
MODEL NO...................MH18CH
GAS TYPE..................... LP-Gas
GAS SUPPLY PRESSURE
TO REGULATOR.............MAX 200 psi (1380 kPa)
MIN 5 psi (34.5 kPa)
MANIFOLD
PRESSURE.....................11” W.C
Do not exceed the gas supply pressures shown on rating plate
for Model MH18CH. The maximum inlet gas supply pressure and
the minimum inlet gas supply pressure (for purposes of input
adjustment) for LP-Gas are shown as follows:
WARNING
DO NOT EXCEED 14” W.C. (1/2 psi) INLET
PRESSURE TO HEATER.
VENTILATION
WARNING
THIS APPLIANCE IS UNVENTED AND MUST BE
USED ONLY IN A WELL VENTILATED AREA.
The flow of combustion and ventilation air must not be
obstructed. DO NOT use in a tightly enclosed area. Any
combustion process requires and consumes oxygen, and may
produce carbon monoxide. This heater must be operated with
adequate ventilation. Two openings directly to the outdoors must
be provided, one low and one high, preferably on opposite sides
of the area to be heated. Each of these openings must provide
at least three square inches of combustion air-intake area and
exhaust outlet area for every 1000 BTUs per hour of heater input
rate in order to complete the combustion/ventilation process.
Provide additional ventilation for any additional fuel-burning
appliances and/or additional occupants.
CLEARANCE (Minimum clearances to combustible materials)
MODEL NO. BTU/HR RATING NORMAL OPERATING CLEARANCES TO
TYPE GAS POSTION COMBUSTIBLES
LP TOP SIDES BACK FRONT
MH18CH 18,000* VERTICAL 24” 12” 0” 72”
*Tank size and tank temperature can directly affect BTU output
CONTENTS
Specifications and Warnings ............................................. 2
General Information .......................................................... 3
Replacement Parts List ................................................... 7-8
Service and Parts Ordering Information ........................... 10
WARNING: Fuels used in liquefied
propane gas appliances, and the products of
combustion of such fuel, can expose you to
chemicals including benzene, which is known to
the state of California to cause cancer and cause
birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov.
FOR YOUR SAFETY
Do not use this heater in a space where
gasoline or other liquids having flammable
vapors are stored or used.
The heater is designed and approved for use as a construction
heater under ANSI Z83.7 - 2017 / CSA 2.14 - 2017.
We cannot anticipate every use which may be made of our
heaters. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF
YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing
products in specific applications. Your local authority can advise
you about these.
This appliance is intended to be used primarily for the heating of
buildings under construction, alteration or repair.
WARNING: THIS PRODUCT CAN
EXPOSE YOU TO CHEMICALS INCLUDING LEAD
AND LEAD COMPOUNDS, WHICH ARE KNOWN
TO THE STATE OF CALIFORNIA TO CAUSE CANCER
AND BIRTH DEFECTS OR OTHER REPRODUCTIVE
HARM. FOR MORE INFORMATION GO TO WWW.
P65WARNINGS.CA.GOV.
Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
2
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
GENERAL INFORMATION
A. Your portable gas-fired infra-red heater comes fully assembled
and is tested at the factory for proper gas and input as stated
on the nameplate.
B. Each heater is equipped with a 100% safety shutoff, push
button valve which will automatically stop the flow of gas in
the event the heater fails to operate for any reason. A tip over
switch and an excess flow check are also standard on the
model MH18CH.
C. Before proceeding with this installation, be sure to inspect
for damages. The freight company must be notified of any
damages and request that an inspection be made. Enerco
Technical Products will send replacements for damaged parts
only after receiving a signed inspection report to prove the
liability of the freight company.
FOR SAFE OPERATION
1. READ THESE INSTRUCTIONS CAREFULLY. Read and
adhere to these instructions. DO NOT allow anyone
who has not read these instructions to assemble, light,
adjust or operate this heater.
2. LP-Gas IS HIGHLY FLAMMABLE. In the event of a leak,
LP-Gas will accumulate and the possibility of a fire is present.
LP-Gas is scented and its strong odor is readily detectable.
Never strike a match, bring any flame or create an electric
spark in an enclosure when you smell LP-Gas. Ventilate the
area thoroughly, move the heater outside, and correct the
source of the leak before attempting to light any appliance.
3. Keep children and pets away from the heater.
4. Check the heater thoroughly for damage. DO NOT operate a
damaged heater.
5. DO NOT modify the heater or operate a heater which has
been modified from its original condition.
6. Use only propane gas.
7. Use only VAPOR WITHDRAWAL propane supply. If there is
any question about vapor withdrawal, ask your propane
dealer.
8. Mount the propane cylinders vertically (shutoff valve up).
Secure the 20# propane tank inside the cabinet to protect it
from damage.
9. DO NOT direct the heater toward another propane tank
within 20 feet of the heater.
10. IMPORTANT Use only the hose and regulator assembly
provided with the heater. Replace only with factory approved
components..
11. This heater is primarily intended for temporarily heating of
buildings under construction, alteration or repair. Area must
be well ventilated. Never use in an occupied dwelling.
12. If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has been
located and corrected. Read enclosed Odor Fade and Propane
Sheet for additional information about detecting propane
leaks.
13. Install the heater such that it is not directly exposed to water
spray, rain and/or dripping water.
14. Maintain minimum clearance from combustible material (like
paper). Page 2. Never place flammable items on the heater.
15. Due to the high surface and exhaust temperatures, adults and
children must observe clearances to avoid burns or clothing
ignition.
16. Operate only on a stable, level surface.
17. DO NOT connect to an unregulated propane source.
18. DO NOT move, handle or service while hot or burning.
19. DO NOT use heater on finished floors.
20. Use only in accordance with local codes or, in the absence of
local codes, with the Standard for the Storage and Handling
of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1,
Natural Gas and Propane Installation Code.
INSTALLATION INSTRUCTIONS
GENERAL
For the U.S. and/or Canada, the installation of this appliance must
comply with local and/or Provincial codes or, in the absence of
these codes,
• With the (U.S.) National Fuel Gas Code, ANSI Z223.1 – Latest
Edition, AND with the (U.S.) Standard for the Storage and
Handling of Liquified Petroleum Gases, ANSI/NFPA 58, OR
• With the current (Canadian) CAN/CGA B149.1 AND B149.2
INSTALLATION CODES.
This heater (including hose and regulator assembly) must be
inspected before each use and at least annually by a qualified
service person. If the hose for Model MH18CH shows evidence
of excessive abrasion or wear, or if the hose is cut, it must
be replaced prior to the heater being put into operation. The
replacement hose assembly shall be that specified by the
manufacturer. See the parts list.
The minimum ambient temperature rating for this heater is 20
degrees F.
This heater incorporates a “Tip Over” switch which automatically
shuts off the burner in the event of tipping. Ensure that this switch
is in the vertical position and is secured with the screws provided.
DO NOT operate this heater with the LP-gas supply cylinder
in any other than the upright position.
Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
3
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
INSTALLATION OF BASE TANK SUPPORT
Packaged Items :
Base Tank Support
Part # 27521
1. Remove the two phillip head screws from the base tank support.
(4) Locking Casters
Part # 27514
2. Align the Base Tank Support tabs (2) with the open slots(2) on the
bottom of the heater along with aligning the bottom heater tabs(2)
with the open slots(2) on the base tank support. Once the tabs and
slots are aligned slide down to lock into place.
SLOTS
TABS
3. Once the Tank Support is aligned and locked into place with
bottom of the heater screw the (2) phillip head screws into
place.
SLOTS
TABS
4. Screw the (4) casters clockwise into threaded openings on the
bottom of the Tank Support and bottom of the heater.
Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
4
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
LOCATION
Although this heater incorporates a “tip over” switch, the heater
and LP-Gas supply cylinder must be located on a hard, flat,
level surface to minimize the risk of accidental tipping. The LP
Gas supply cylinder should be adequately restrained to prevent
accidental tipping. DO NOT OPERATE this heater with the
supply cylinder in any other than the upright position.
This appliance must be installed only in locations where the
potential for physical damage to the appliance (i.e., due to
physical contact) is reduced to a minimum.
Use of this heater in a draft/windy area may decrease its
efficiency. If possible, operate the unit in a draft free area or turn
the face of the heater away from the draft.
WARNING
NEVER USE A FORK LIFT TRUCK TYPE
CYLINDER.
The connection of Model MH18CH to an LP-Gas cylinder must
be made in a well ventilated area using the regulator and hose
assembly supplied with the appliance. DO NOT attempt to adjust
this regulator. It has been preset at the factory to provide safe and
proper operation of the appliance.
IMPORTANT: To install the gas cylinder, you must first remove
the tank mount bracket (ref.# 9 in parts list) located inside heater
housing. After placing cylinder onto the base tank support,
reinstall the bracket to secure the cylinder.
The heater must be located at least six feet away from any LP-Gas
cylinder and must not be directed toward any LP-Gas cylinder
within 20 feet. If more than one heater is used, they and the
supply cylinders must be separated by at least 20 feet.
The gas supply must be turned off at the LP-Gas supply cylinder
when the heater is not in use.
When the heater is to be stored indoors, the connection between
the LP-Gas supply cylinder and the heater must be disconnected
and the cylinder removed from the heater and stored in
accordance with Chapter 5 of the Standard for the Storage and
Handling of Liquefied Petroleum Gases, ANSI/NF-PA 58 (U.S.), OR
CAN/CGA B149.2 (Canada). Never store LP tanks indoors.
Piping must be clean and free from scale or burr.
Before attempting to ignite the appliance, all gas fittings and
connections must be thoroughly checked for gas leaks. Apply a
small amount of a mild soap and water solution to all fittings and
connections and observe for escaping bubbles. If any leaks are
detected, shut off the gas supply to the appliance immediately.
Wait a minimum of five minutes, repair the leak(s) and retest for
leakage. Dry all fittings and connections after leak testing.
WARNING
NEVER USE A FLAME FOR GAS LEAK TESTING.
OPERATING INSTRUCTIONS
WARNING: IF YOU DO NOT FOLLOW
THESE INSTRUCTION EXACTLY, A FIRE
OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY,
OR LOSS OF LIFE.
CAUTION
THIS APPLIANCE IS HOT DURING
NORMAL OPERATION. AVOID
PHYSICAL CONTACT.
CAUTION
DO NOT PLACE CLOTHING OR
OTHER COMBUSTIBLE MATERIALS
ON THIS APPLIANCE.
DO NOT operate this heater if any part has been under
water. Call a qualified service technician to inspect the
appliance and to replace any part of the control system or gas
control valve which has been under water.
This appliance must be installed and operated only in locations
where the potential for physical damage to the appliance is
reduced to a minimum. The owner/operator of this appliance
must ensure that precautions are taken to protect the appliance
from physical damage.
ODOR FADING - NO ODOR DETECTED
• Some people cannot smell well. Some people cannot
smell the odor of the man-made chemical added to
propane (LP) or natural gas. You must determine if you
can smell the odorant in these fuel gases.
• Learn to recognize the odor of propane (LP) gas and
natural gas. Local propane (LP) gas dealers will be more
than happy to give you a scratch and sniff pamphlet.
Use it to become familiar with the fuel gas odor.
• Smoking can decrease your ability to smell. Being
around an odor for a period of time can affect your
sensitivity to that particular odor. Odors present in
animal confinement buildings can mask fuel gas odor.
• The odorant in propane (LP) gas and natural gas
is colorless and the intensity of its odor can fade
under some circumstances.
• If there is an underground leak, the movement of gas
through the soil can filter the odorant.
• Propane (LP) gas odor may differ in intensity at different
levels. Since Propane (LP) gas is heavier than air, there
may be more odor at lower levels.
• Always be sensitive to the slightest gas odor. If you
continue to detect any gas odor, no matter how small,
treat it as a serious leak. Immediately go into action as
discussed previously.
Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
5
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
LIGHTING AND SHUT-DOWN
Lighting the Heater:
1. Use only the fuel intended for this appliance. Check the
appliance rating plate for the correct fuel information.
2. Turn off the main gas supply to the appliance. Wait five
minutes.
3. Turn on the main gas supply.
4. Depress and turn Control Knob counterclockwise to
“PILOT” position and hold for 15 seconds. With the
Control Knob still depressed rotate to the “OFF” position
and back to the “Pilot” position to generate a spark
at the ignitor. (If needed, repeat until pilot lights).
Continue to hold control knob down in “PILOT” position
of 30 seconds (See Figure 1).
5. Release the control knob. If the pilot does not stay lit,
repeat Step 4. If the pilot stays lit, turn the control knob
counterclockwise to the desire heat setting.
IMPORTANT: DO NOT attempt to adjust the main
burner input using the main gas supply valve, as this
may cause the thermocouple to shut down the burner.
Shut-down instructions:
To turn the heater OFF:
1. Turn the control knob clockwise to the “OFF” position.
2. Turn off the propane tank by turning the tank valve knob
clockwise until it stops.
3. If the heater is not going to be used for an extend period
of time disconnect the regulator/hose assembly from the
propane tank.
• Turn the heater off and wait until it has completely cooled (at
least 20 minutes) before cleaning.
• Clean the outside of the heater using a damp cloth. DO NOT
clean the heater by spraying water on it. Wipe the outside of
the heater off with a dry cloth after cleaning.
• Clean the inside of the heater using compressed air. Using
an OSHA appoved blow gun, blow compressed air back and
forth along the entire burner face to dislodge dust and debris
from the ceramic tiles. Using an OSHA appoved blow gun,
blow compressed air through venturi from the control end of
the heater.
• Clean the orifice of each burner with a #68 drill bit
(for LP-Gas).
• Clean the thermocouple lead.
DO NOT operate this heater if any part has been under
water. Call a qualified service person to inspect the appliance
and to replace any part of the control system or gas control valve
which has been under water.
This heater must be inspected at least annually by a qualified
service person.
MAINTENANCE INSTRUCTIONS
This heater (including hose and regulator assembly) must be
inspected before each use. If the hose for Model MH18CH shows
evidence of excessive abrasion or wear, or if the hose is cut, it
must be replaced prior to the heater being put into operation.
The replacement hose assembly shall be that specified by the
manufacturer. See the parts list.
The appliance area must be kept free and clear of combustible
materials, gasoline and other flammable vapors and liquids at all
times.
The flow of combustion and ventilation air must not be
obstructed.
Cleaning the heater:
Periodically, the heater must be cleaned of all dirt and dust
particles.
DANGER
DO NOT ATTEMPT TO CLEAN THE HEATER
WHILE IT IS OPERATING OR WHILE IT IS
STILL HOT.
Figure 1
Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
6
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
TROUBLESHOOTING INFORMATION:
(Model MH18CH)
If burner lights, but goes out when button is released.
CHECK
• Loose wires on tipover switch.
• Loose lead wire at control valve and ODS/Pilot
Assembly.
• Loose thermocouple and tighten if necessary.
• Defective ODS/Pilot Assembly. Replace if necessary.
• Defective control. Replace if necessary.
• Defective tip over switch. Replace if necessary.
Tip-Over Switch Arrangement
NOTE: The purpose of the Tip-Over Switch is to stop the flow of
gas when heater is accidentally knocked over. When and if the
heater is knocked over, simply stand heater up, wait 5 minutes
and relight.
REPLACEMENT PARTS LIST
ITEM
NO.
127510PANEL, FRONT, MH18CH
227 511PANEL, TOP, MH18CH
327 512SHIELD, RADIATION, MH18CH
427 513KNOB, CONTROL, MH18CH
527514CASTER, LOCKING, MH18CH
627 515ASSEMBLY, HOSE, REGULATOR
727516VALVE, CONTROL, MH18CH
827517GUARD, WIRE, MH18CH
927518BRACKET, TANK, MOUNT,
104211 6SWITCH, TIPOVER, MH18CH
1227524SHIELD, HEAT, MH18CH
PART
NUMBER
DESCRIPTION
1327520BASE, METAL, MH18CH
1427521BASE, TANK, SUPPORT, MH18CH
1527530SCREW, HAND, BASE, MH18CH
1627531BRACKET, HOUSING, SUPPORT
1727529REFLECTOR, MH18CH
1827528GUARD, WIND, MH18CH
1927522BRACKET, ODS, MH18CH
2027523ODS, MH18CH
2127526ASSEMBLY, BURNER, MH18CH
2227941O-RING, ORIFICE
2327527ORIFICE, MH18CH
2427525BRACKET, VALVE, MOUNT
2527532HOLDER, ORIFICE, MH18CH
Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
7
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
Portable Propane Caninet Heater • Model MH18CH
IF SERVICE IS REQUIRED
PLEASE DO NOT RETURN THIS APPLIANCE TO YOUR STORE
For information regarding service, please call our Toll-Free
Number: 1-800-251-0001.
Our office hours are 8:00 AM to 5:00 PM, Eastern Time Zone,
Monday through Friday
Please include the model number, date of purchase and
description of problem in all communication.
Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
8
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
WARNING
Air Quality Hazard
• Do not use this heater for heating human living quarters.
• Use of direct-fired heaters in the construction environment can result in exposure to levels of CO, CO2, and NO2 considered to be hazardous to health and potentially life threatening.
• Do not use in unventilated areas.
• Know the signs of CO and CO2 poisoning.
• Headaches, stinging eyes
• Dizziness, disorientation
• Difficulty breathing, feels of being suffocated
• Proper ventilation air exchange (OSHA 29 CFR 1926.57) to support combustion and maintain acceptable air quality shall
be provided in accordance with OSHA 29 CFR Part 1926.154, ANSI A10.10 Safety Requirements for Temporary and Portable Space Heating Devices and Equipment used in the Construction Industry or the Natural Gas and Propane Installation Codes CSA B149.1.
• Periodically monitor levels of CO, CO2 and NO2 existing at the construction site – at the minimum at the start of
the shift and after 4 hours.
• Provide ventilation air exchange, either natural or mechanical, as required to maintain acceptable indoor air quality.
USA 8-Hr Time weighted average
(OSHA 29 CFR 1926.55 App A)
CO50 ppm25 ppm
CO
2
NO
2
(Short Term Exposure Limit = 15 minutes)
CO100 ppm
CO
2
NO
2
5000 ppm5000 ppm
USA – Ceiling Limit
5 ppm
Canada 8-hr time weighted average
WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
3 ppm (Reg 833)
Canada STEL (15 minutes Reg 833/1 hour
WSBC) WorkSafe BC OHS Guidelines Part
5.1 and Ontario Workplaces Reg 833
15000 ppm (WSBC)
30000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
• Ensure that the flow of combustion and ventilation air exchange cannot become obstructed.
• As the building ‘tightens up’ during the construction phases ventilation may need to be increased.
Installation of this appliance at altitudes above 2000 ft (610 m) shall be in accordance with local codes, or in the absence of
local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or National Standard of Canada, Natural Gas and Propane
Installation Code, CSA B149.1
The heater has been shipped from the factory set up for operation on propane gas.
Operating Instructions and Owner’s ManualPortable Propane Cabinet Heater
9
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place
instructions in a safe place for future reference. Do not allow anyone who has
not read these instructions to assemble, light, adjust or operate the heater.
WARNING:
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE
AGENCY.
PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any Mr. Heater local dealer or
direct from the factory
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001
www.mrheater.com • www.enerco.com
Our office hours are 8:00 AM – 5:00 PM, EST, Monday through Friday.
Please include the model number, date of purchase, and description of problem in
all communication.
MR. HEATER
MODEL
MH18CH
WARRANTY
MR. HEATER warrants that Infra Red Heaters manufactured and sold will be free from defects
in material and workmanship.
Parts assemblies, controls, etc. furnished by Enerco Group, Inc. will carry a one (1) year
warranty on the applicable warranties of the suppliers.
The sole responsibility of Enerco Group, Inc. under this warranty shall be to replace or repair
any part for which a written claim is made to Enerco Technical Products within the time limit
of this warranty which is returned upon request to Enerco Group, Inc. – F.O.B. Cleveland,
Ohio – or F.O.B. any Enerco Technical Products authorized service facility and which is proved
to be defective upon inspection by Enerco Technical Products.
This warranty shall not apply to any part or product which has been subjected to misuse or
neglect, damaged by accident, or rendered defective by reason of improper installation. THIS
WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, and
of any other responsibility of Enerco Technical Products for parts or products sold by Enerco
Technical Products, including consequential or special damages. This Warranty gives you
specific legal rights, and you may have other rights which vary from state to state.
Enerco Group, Inc. reserves the right to make changes at any time, without notice or
obligation, in colors, specifications, accessories, materials and models.
PRODUCT REGISTRATION: Thank you for your purchase.
Please log in to http://www.egiregistration.com to register your product.
MR. HEATER, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
Enerco and Mr. Heater are registered trademarks of Enerco Group, Inc.