Workin’
Warm.
Workin’
Tough.
CONSTRUCTION HEATERS
1
Small Jobsites
Model # Description
F170250 HS50K 50,000 BTU/HR
F170275 HS75KT 75,000BTU/HR
STANDARD FEATURES:
• Heavy Construction - Illuminated On-Off Switch - 115 V 60Hz
• Flame Safety/Overheat Safety Shutoff
• Enclosed Motor - Fuel Gauge • Continuous Ignition
• Cord Wrap (HS75KT only) - High Output Fan
• Larger “Glove-Friendly” Controls
• CSA Certified
Large Jobsites
Model # Description
F170325 HS125KT 125,000 BTU/HR
F170375 HS175KT 175,000 BRU/HR
F170380 HS210KT 210,000 BTU/HR
THE ONLY HEAVY DUTY
KEROSENE HEATER
BUILT FOR THE JOBSITE
STANDARD FEATURES:
• Heavy Construction - Illuminated On-Off Switch -115 V 60Hz
• Flame Safety/Overheat Safety Shutoff
• Enclosed Motor - Fuel Gauge - High Output Fan • Continuous Ignition
• Large Heavy-Duty Handles w/cord wrap
• 10” Pneumatic Tires
• Larger “Glove-Friendly” Controls
• CSA Certified
Big Projects
Model # Description
F151089 HS3500DF 360,000 BTU/HR
F151100 HS6000DF 610,000 BTU/HR
STANDARD FEATURES:
• Heavy Construction - Built-In Oil Burner - 115 V 60Hz
• Flame Safety/Overheat Safety Shutoff
• Electronic Flame Control System • Continuous Ignition
• Stainless Steel Heat Exchanger
• High Output Fan
• Pre-Heated Oil Filter (HS6000DF only) - Pre-Purge And Ventilation Cycles
• Optional Remote Thermostat • CSA Certified
SPECIFICATIONS: HS50K HS75KT HS125KT HS175KR HS210KT HS3500DF HS6000DF
Stock Number F170250 F170275 F170325 F170375 F170380 F151089 F151100
Output (BTU/HR) 50,000 75,000 125,000 175,000 210,000 360,000 610,000
Heang Area (SQ. FT.) 1,200 1,750 3,000 4,250 6,000 9,400/75,000 14,250/114,000
CFM Output 165 240 275 400 400 1,800 2,800
Fuel Consumpon (GAL/HR-L/HR) .38/1.43 .56/2.11 .77/2.91 1.15/4.35 1.60/6.05 2.75/10.41 4.4/16.65
Tank Capacity (GAL-L) 4/15 6/22 14/52 14/52 14/52 27.7/104 35.6/134
Tires/Wheels NA NA 10” Pneumac 10” Pneumac 10” Pneumac 10” Pneumac 10” Pneumac
Operang Hours On Full Tank 11 11 15 10 8 9.5 8.6
Shipping Size (L x W x H) 32” x 14” x 14.5” 32” x 14.25” x 17” 42” x 18” x 22” 42” x 18” x 22” 42” x 18” x 22” 66” x 27” x 39” 76” x 27” x 39”
HEAVY DUTY PORTABLE DIRECT-FIRED FORCED AIR HEATERS
Shipping Weight 43 lbs. 43 lbs. 74 lbs. 81 lbs. 87 lbs. 227 lbs. 247 lbs.
Mul-Fuel (No. 1 Or No. 2 Diesel
Oil, Kerosene, JP-8 Or Jet A)
Oponal Remote Thermostat NA NA NA NA NA F150035 F150035
Yes Yes Yes Yes Yes Yes Yes
2
Large Jobsites
Model # Description Fuel
F151010 HS1000ID 110,000 BTU/HR
F151020 HS2000ID 205,000 BTU/HR Oil
F151030 HS3000ID 300,000 BTU/HR Oil
F151040 HS4000ID-HD 400,000 BTU/HR Oil With 2-Stage Burner
F151092 HS4000IDG-HD 380,000 BTU/HR Dual-F uel: N atur al Gas/LP
HEAVY DUTY PORTABLE INDIRECT-FIRED FORCED AIR HEATERS
Oil
CSA Certified
HS1000ID
F151010
SPE CIFICA TI ONS: HS1000ID HS2000ID HS3000ID HS4000ID-HD HS4000IDG-HD
Operang Hours On Full
Oil Fuel Consumpon (GAL/
LP Fuel Consumpon (GAL/
NG Fuel Consumpon
Tank Capacity (GAL)
Max Lenght Of Duct
Shipping Size (L x W x H)
Duct Adapter
Stock Number
LP/NG Burner
Oil Burner
Input (BTU/HR)
CFM Output
Tank
HR-L/R)
HR-L/R)
(CUBIC/FT)
Fuel Type
Power Required
Duct Diameter
Shipping Weight (LBS)
HS2000ID
F151020
F151010 F151020 F151030 F151040 F151092
NA NA NA NA Included
Included Included Included Included NA
110,000 205,000 300,000 400,000 380,000
880 1,530 2,500 2,760 3,250
12 11 12.5 15 NA
0.81/3.06 1.56/5.90 2.18/8.25 2.68/10.14 NA
NA NA NA NA 4.2/15.89
NA NA NA NA 380
Oil Oil Oil Oil NG/LP
11.9 17.2 27.7 57 NA
115V 115V 115V 115V 115V
12” 14” 16” 20” 20”
25 50 50 100 100
47” x 18” x 27” 9” x 21” x 42” 76” x 29” x 46” 70” x 29” x 50” 72” x 30” x 31”
94 176 264 330 306
Heat Duct
Shown With
Optional Duct
Adapter
HS3000ID
F151030
Dual Duct
Adapter
Remote
Thermostat
w/32” cord
HS4000IDHD
F151040
OPTIONAL ACCESSORIES: HS1000ID HS2000ID HS3000ID HS4000ID-HD HS4000IDG-HD
Duct Adapter F151015 (12”) F151025 (14”) F15035 (16”) F151045 (20”) F151045 (20”)
Dual Duct Adapter 2-12* NA F151052 F151032 NA NA
Dual Duct Adapter 2-16* NA NA NA F151042 F151042
3-Way Duct Adapter 3-12” NA NA NA F151043 F151043
Flexible Heat Duct (25Ft.)
12” F150040 F150040 F150040 F150040 F150040
14” NA F150043 NA NA NA
16” NA NA F150050 F150050 F150050
20” NA NA NA F151084 F151084
Remote Thermostat F150035 F150035 F150035 F150035 F150035
Li Bracket Kit F150031 F150031 F150031 Included Included
External Tank Kit F150032 F150032 F150032 F150032 NA
Oil Fuel Tank Included Included Included Included NA
Heavy-Duty Frame And
Wheel Kit
NA NA F150285 Included Included
3
new stronger design
built for the jobsite
SMALL WORKSITES
Model # Description Heats Up To Operates Up To
F170035 HS35FA 35,000 BTU/HR 800 Sq. Ft. 12 hrs. on a 20 lb. tank
F170060 HS60FAV 30,000-60,000 BTU/HR 1,250 Sq. Ft. 14 hrs. on a 20 lb. tank
F170085 HS85FAV 50,000-85,000 BTU/HR 2,000 Sq. Ft. 8 hrs. on a 20 lb. tank
F170125 HS125FAV 75,000-125,000 BTU/HR 3,000 Sq. Ft. 11 hrs. on a 40 lb. tank
LARGE JOBSITES
Model # Description Heats Up To Operates Up To
F170170 HS170FAVT 125,000-170,000 BTU/HR 4,000 Sq. Ft. 17 hrs. on a 100 lb. tank
F170180 HS170NG 150,000 BTU/HR 3,500 Sq. Ft. Natural Gas
F172425 HS400FAVT 250,000-400,000 BTU/HR 9,000 Sq. Ft. 17 hrs. on (2) 100 lb. tanks
CSA Certified
HS35FA
F170035
SPECIFICATIONS:
Stock Number F170035 F170060 F170085 F170125 F170170 F170180 F172425
Output (BTU/HR_ 35,000 30,000-60,000 50,000-85,000 75,000-125,000 125,000-170,000 150,000 250,000-400,000
Output CFM 100 300 300 350 450 450 1400
Fuel Propane Gas Propane Gas Propane Gas Propane Gas Propane Gas Natural Gas Propane Gas
Min. LP Tank Size 20 lb. 20 lb. 20 lb. 40 lb. 100 lb. NA 100 lb.
Fuel Consumpon (lbs/hr) 1.6 1.2 to 2.08 2.3 to 3.9 3.5 to 5.8 5.8 to 7.8 138 cub. ./r. (NG) 11.5 to 18.5
Pressure Regulator Sengs 10 PSI 28” W.C. 28” W.C. 28” W.C. 28” W.C. 4” W.C. 20 PSI
Adjustable Height Control - Yes Yes Yes Ye s Ye s -
Flame Safety Ye s Yes Ye s Ye s Ye s Ye s Ye s
High Temperature Limit
Propane Hose-20.
POL/Excess Flow Check Valve Yes Yes Ye s Yes Yes NA Yes
Shipping Size (L x W x H) 19” x 11.5” x 14” 18.5” x 11.5” x 14” 21” x 11.5” x 16” 20.25” x 12” x 15.5” 26.5” x 11.5” x 16.75” 26.5” x 11.5” x 16.75” 38.58” x 15” x 22.25”
Net Weight ( Includes Hose/
Regulator/POL Assembly)
Switch
Ignion Piezo Connuous Connuous Connuous Automac Solid State Automac Solid State Automac Solid State
Thermostat - - - - Built-in Built-in Built-in
Power Required 115 V. 60 Hz 3a 115 V. 60 Hz 3a 115 V. 60 Hz 3a 115 V. 60 Hz 3a 115 V. 60 4a 115 V. 60 4a 115 V. 60 4a
1/4” I.D. w/Regulator
Shipping Weight 17 lbs. 20 lbs. 20 lbs. 25 lbs. 34 lbs. 34 lbs. 51 lbs.
Shipping Cube 1.8’ 1.7’ 2.2’ 2.7’ 3.0’ 3.0’ 7.5’
HS125FAV
F170125
HA35FA HS60FAV HS85FAV HS125FAV HS170FAV HS170NG HS400FAVT
240 F 240 F 240 F 240 F 240 F 240 F 240 F
and POL
15 lbs. 16lbs. 18 lbs. 23 lbs. 32 lbs. 32 lbs. 47 lbs.
3/8” I.D w/Regulator
and POL
HS170FAVT
F170170
3/8” I.D. w/Regulator
and POL
3/8” I.D. w/Regulator
and POL
3/8” I.D. w/Regulator
and POL
HS400FAVT
F172425
NA
1/4” I.D. w/Regulator
and POL
PORTABLE PROPANE AND NATURAL GAS FORCED AIR HEATERS
4