HeatPumps4Pools THP05NP, THP14NP, THP08NP, THP17NP, THP10NP Installation And User Manual

...
INSTALLATION AND USER MANUAL
Swimming Pool Heat Pump
Thank
you for choosing our product and trusting our company.
This manual is to provide you with necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent use.
Swimming Pool Heat Pump
Thank
you for choosing our product and trusting our company.
This manual is to provide you with necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent use.
Content
ⅠⅠⅠⅠ
. Introduction ................................................................................. 1
Safety precaution ........................................................................................ 1
Important features of this product .............................................................. 1
Parameters of product range ..................................................................... 3
ⅡⅡⅡⅡ
. Installation Guide ........................................................................ 5
Transport it in proper manner .................................................................... 5
Determining Optimum installation position ............................................... 5
Water pipe connection ................................................................................ 8
Electric connection .................................................................................... 8
Trial after first installation ....................................................................... 10
ⅢⅢⅢⅢ
. Operation guide.......................................................................... 11
LED controller ......................................................................................... 11
Testing ...................................................................................................... 12
Precautions .............................................................................................. 13
ⅣⅣⅣⅣ
. Maintenance............................................................................... 15
ⅤⅤⅤⅤ
. Trouble shooting ........................................................................ 16
Common faults ......................................................................................... 16
Failure code ............................................................................................. 17
Appendix: Heating priority (Optional) ........................................................
1
. Introduction
Safety precaution
- The swimming pool heat pump must be installed by a qualified electrician.
- Always install a differential protective device with a sensitivity of 30 mA on the
distribution unit before the electrical box.
- Always fit a circuit breaker for all active conductors on the power supply of the box.
- In case of abnormal behavior (noise, smell, smoke), cut off the power supply immediately
and contact you reseller. Do not attempt to repair the system yourself.
- Keep the main power supply switch beyond the reach of children.
- Rotating parts: Never remove the grid from the fan. Never place your hand or any other
object in the air inlet or outlet of the heat pump.
Important features of this product
Water Flow Switch
The water flow switch contacts are closed when pressure is applied as pool water flows through the titanium heat exchanger. Low flow rates as well as no flow will let these contacts open and this will cause the unit to shut down. The LED display will read “EE3” if the water pressure is not sufficient.
Always switch off power supply before working on the heat pump and stop the hydraulic circuit.
This swimming pool heat pump is equipped with safeguards that will stop operation to protect your unit automatically and display error code on the LED controller in case of some events as following:
Caution: Danger of electric shock
2
High / Low Refrigerant Pressure Switches
The high-pressure switch senses the refrigerant pressure in the sealed refrigeration system and shuts the heat pump down in the event unsafe operating pressures are reached. The heat pump will automatically reset after the system pressure drops back to normal operating pressures. When this switch is tripped, digital displays will read “EE1”
The low-pressure switch senses the refrigerant pressure in the sealed refrigeration system to protect against certain conditions that could be detrimental to compressor life. The switch shuts the unit down in the event of loss of refrigerant or not enough refrigerants. The switch automatically resets when the pressure rises to normal operating pressures. The display will show “EE2” if this switch is tripped.
Time Delay
All models use a 3-minute time delay to prevent repeated tripping of the compressor thermal overload, which is caused by attempting startup before system pressures are equalized. Any interruptions, outside of power loss, will result in a 3-minute time delay.
3
Parameters of product range
Specification
*C.O.P: Coefficient of performance
Note:
1. Machine can work well under air temp 7
℃℃℃℃
~43℃℃. Performance cannot be guaranteed outside the
operating ranges and depend on the exterior conditions of use, identified to select suitable mode (such as location, area of swimming pool, and numbers of swimmer.)
2. Above parameters are subjected to adjustment periodically for technical improvement with further notice.
Please refer to nameplate on each machine for accurate information.
Model
THP05NP THP08NP THP10NP THP12NP THP14NP THP17NP
Function
Heating capacity kW (air 26℃℃,water 26℃℃℃℃)
5.0 7.5 9.6 14.0
14.0
17.0
C.O.P. (air 26℃℃,water26
)
5.5 5.3 5.7 5.6 5.6 5.5
Heating capacity kW (air 15℃℃, water 26℃℃℃℃)
3.3 5.0 6.5 10.0
10.0
11.2
C.O.P.(air15℃℃,water26
)
4.2 4 4.3 4.3
4.3
4.3
Power supply
230V/1Ph/50Hz
Rated Input power kW
0.8 1.3 1.5 1.8
2.3
2.6
Rated Input current A
3.5 5.2 6.5 7.8
10.0
13.0
Advised water flux m³/h
2-3 3-4 4-6 4-6
5-7
6.5-8.5
Water pipe in-out spec mm
50 50 50 50
50
50
Net weight /Gross weight Kg
38/45 40/45 55/63 60/68
70/80
72/82
4
.Dimension:
Above data is subject to modification without notice
A B C D E F G H
THP05NP 315 429 312 340 800 250 76 558 THP08NP 315 429 312 340 800 220 76 558 THP10NP 315 590 312 340 961 280 77 658 THP12NP 315 590 312 340 961 320 77 658 THP14NP 395 590 392 420 961 310 77 658 THP17NP 395 590 392 420 961 310 77 658
Name
Size(mm)
Model
A D
5
. Installation Guide
Transport it in proper manner
1. Transport it in original package.
2. When moving the machine, do not lift the water nozzle since the titanium heat exchanger in side the machine will be damaged. Please refer to the following wrong operation picture:
Determining Optimum installation position
The location of the swimming pool heat pump is very important for efficient operation, think about the following factors when choose the proper place:
Avoidance of air recirculation Easy for wire and pipe connection and Water pipe line of long water lines (not
longer than 10m.) from heater to pool.
Easy for maintenance. Drainage of condensation.
!!Warning:
Because the machine is very heavy, the water nozzle can not bear to be lifted during transit or installation
The manufacturer cannot accept responsibility for damage incurred or repairs necessitated due to improper handling of our equipment.
This swimming pool heat pump must be installed by a skilled team.
A
ttention!
6
Pay attention to the following points:
1The heat pump must be installed OUTSIDE in a well ventilated place to avoid air
recirculation or in a place with adequate room area both for installation and maintenance. Please refer to the following illustration:
A minimum of 500mm of clearance from walls, shrubbery, equipment, etc. is required around the entire pump circumference. This allows for ample air intake. No less than 2500mm clearance on the air outlet is required to prevent recirculation of air. We recommend not to place the unit underneath eaves, decks, or porches, as this causes recirculation of discharged air, or the efficiency of the heater will be reduced or even stopped.
2The heater should be located on a solid, level and non-corrodible structure that is
capable of supporting the weight of the heat pump. It must be fixed by bolts (M10) to concrete foundation.
Wrong installation
!!Warning:
Don’t install the heat pump close to a wall or plants. And Never inside a closed building!
7
3The heat pump should be far from any source of combustibles and corrosive material to
avoid any damage to this unit.
Never place heat pump near sprinkler systems, evaporation of acid or alkaline gas. If you live in an oceanfront area, the heat pump should be placed out of direct spray of sand and salt, since this will also clog, damage, and corrode the unit. You may consider protecting your heat pump by planting shrubbery or a privacy fence between the unit and the prevailing beachfront wind.
4When the machine is running, there will be condensation water discharged from the
bottom. Make sure there is enough space for water drainage.
TIPS: HEAT PUMPS GENERATE WATER CONDENSATION DURING
NORMAL
OPERATION. THIS SHOULD NOT BE MISTAKEN FOR A LEAK IN THE UNIT.
!!Warning:
The machine must not be hung onto the wall with soft pipe since the inlet/outlet union on the machine can’t hold weight.
The machine must always be connected with hard pipe!
8
Water pipe connection
- The water flow through this machine needs to be driven by an appended water pump
(Prepared by the user). The recommended pump specification-flux is shown on the product specification and Max. lift 10m;
- Pipe length between heat pump and swimming pool should not be longer than 10m.
Electric connection
- Wiring must be handled by a professional technician according to the circuit diagram as
following.
- Connect the heat pump to appropriate power supply and the voltage should comply with
the rated voltage of each model stated on the specification.
- Make sure the machine is ground well.
- Always put leakage protector according to the local code for wiring (leakage operating
current 30mA).
- Protect the circuit with a suitable circuit breaker or fuse.
Noted: The drawing is just for demonstration, and layout of the pipes for reference.
9
Recommendation for protecting devices and cable specification
Above data is subject to modification without notice.
N
ote: The above data is adapted to power cord 10m. If power cord is 10m, wire
diameter must be increased. The signal cable can be extended to 50m at most.
MODEL
THP05NP THP08NP THP10NP THP12NP THP14NP THP17NP
Breaker
Rated
Current A
6 15 15 15 20 25
Rated
Residual Action Current mA
30 30 30 30 30 30
Fuse
A
6 15 15 15 20 25
Power Cord (mm2)
3×1.5 3×2.5 3×2.5 3×2.5 3×2.5 3×4
Signal cable (mm2) 3×0.5 3×0.5 3×0.5 3×0.5 3×0.5 3×0.5
Attention: The swimming pool heater must be earthed well.
10
Trial after first installation
Inspection before connecting power supply
- Check the installation of the whole machine and the pipe connections according to the
pipe connecting drawing.
- Check the electric wiring according to the electric wiring diagram, and ground well.
- Make sure no blockage on the air inlet and outlet, or the efficiency of the heater will be
reduced or cause machine to stop operation.
Trial after connecting power supply
- Connect the machine with electric power supply, then relative information will display on
the LED controller.
(For Detail operation of LED controller, please refer to Chapter “Operation guide”.)
- Start the water pump before turning on the Machine to avoid any damage.
- Press power on/off on LED controller to turn on/off machine.
- During the first start of machine, please check if there is any water leakage in the piping
connection system. Then set suitable temperature.
- After the swimming pool heater runs, check if there is any abnormal noise or smell.
Special cases:
- In the event of an unexpected power cut, the heat pump will automatically restart. Check
the setting and adjust if necessary.
- In the event of an expected power cut, switch off the heat pump. When power is restored,
switch on the pump, check the settings and adjust if necessary.
- Always switch off the machine in stormy weather.
Always Start the water pump before turning on this machine
Turn off
this machine
before
turn
ing off
the water p
ump.
Attention:
In any abnormal situation, such as serious noise, smell or smoking, please
cut the
power supply immediately and inform resellers, never try to repair it by yourself.
11
. Operation guide
LED controller
Power on/off
HEAT Shows the heat mode has been set Down-ALLOW Set required temperature UP-ALLOW Set required temperature LED screen Display temperature and machine failure code
1.. Operation Display
The display shows Temperature of the swimming pool water when the machine is on.
2.. Water temperature setting
A Available no matter the machine is on or off;
BPress the key or to set water temperature. The controller
indicates twinkling temp. Press
or adjust to your required
water temp;
C5 seconds later, the controller display will back to the normal mode.
Power On/Off
Water Temp
12
D When you want to check setting temperature, press or to
see the current setting.
Testing
1111.
Inspection before use
A. Check installation of the whole machine and the pipe connections
according to the pipe connecting drawing;
B. Check the electric wiring according to the electric wiring diagram and
earthing connection;
C. Make sure that the main machine power switch is off; D. Check the temperature setting; E. Check the air inlet and outlet.
2222.
Trial
A. The user must “Start the Pump before the Machine, and Turn off the
Machine before the Pump”, or the machine will be damaged;
B. The user should start the pump, check for any leakage of water; and then
set suitable temperature in the thermostat, and then switch on power supply;
C. In order to protect the swimming pool heater, the machine is equipped
with a time lag starting function, when starting the machine, the blower will run 1 minutes earlier than the compressor;
D. After the swimming pool heater starts up, check for any abnormal noise
from the machine.
13
Precautions
. Attention
A. Set proper temperature in order to get comfortable water temperature to
avoid overheating or overcooling;
B. Please don’t stack substances that can block air flow near inlet or outlet
area, or the efficiency of the heater will be reduced or even stopped;
C. Please don’t put hands into outlet of the swimming pool heater, and don’t
remove the screen of the fan at any time;
D. If there are abnormal conditions such as noise, smell, smoke and electrical
leakage, please switch off the machine immediately and contact the local dealer. Don’t try to repair it yourself;
E. Don’t use or stock combustible gas or liquid such as thinners, paint and
fuel to avoid fire;
F. In order to optimize the heating effect, please install heat preservation
insulation on pipes between swimming pool and the heater. During running period of the swimming pool heater, please use a recommended cover on the swimming pool;
G. Connecting pipes of the swimming pool and the heater should be 10m,
or the heating effect of the heater cannot be ensured;
H. This series of machines can achieve high efficiency under air temperature
of +15℃~+25.
. Safety
14
A. Please keep the main power supply switch far away from the children; B. When a power cut happens during running, and later the power is restored,
the heater will start up automatically. So please switch off the power supply when there is a power cut, and reset temp when power is restored;
C. Please switch off the main power supply in lightning and storm weather to
prevent from machine damage that caused by lightning;
D. If the machine is stopped for a long time, please cut off the power supply
and drain water clear of the machine by opening the tap of inlet pipe.
15
. Maintenance
AIn winter season when you don’t swim:
1. Cut off power supply to prevent any machine damage.
2. Drain water clear of the machine.
3. Cover the machine body when not in use.
B. Please clean this machine with household detergents or clean water,
NEVER use gasoline, thinners or any similar fuel.
C. Check bolts, cables and connections regularly.
“Cut off” power supply of the heater before cleaning, examination and repairing
Caution: Danger of electric shock
!!Important:
Unscrew the water nozzle of inlet pipe to let the water flow out.
When the water in machine freezes in winter season, the titanium heat exchanger may be damaged.
16
. Trouble shooting
Common faults
Phenomenon Possible reason
Not
failure
A.Noticeable White vaporous
cold air or water.
B. Plopping sound
A. The fan motor stops automatically for defrost. B. There will be sound from the solenoid valve when
machine starts or ends to defrost.
C. During machine working or just stopping, a sound like
water flow, in 2~3 minutes of starting the machine. This sound comes from refrigerant flowing or water drainage during dehumidification.
D. The plopping sound during the operation is caused by
expand on heating and contract on cooling of the heat exchanger when temperature varies.
Automatic start or stop Check whether there is mal-function on the timer.
Recheck
Heat pump does not run A. Power supply failure
B. Check manual power supply switch to make sure it is on. C. Fuse burned. D. If machine auto- protector has started (check failure code display on controller).
E. Check whether machine automatic on or off was set. Running but not heating or cooling
Check if there is blockage on air inlet and outlet of the unit.
Note: If the following conditions happen, please stop the machine and cut off the power
supply immediately, then contact your dealer: aInaccurate switch action; bThe fuse is frequently broken or leakage circuit breaker jumped.
17
Failure code
NO.
Failure code
Failure description Action
1 EE 1 High pressure protection Contact your dealer. 2 EE 2 Low pressure protection Contact your dealer.
3 EE 3 Low water pressure protection
1. Check if there is no water through the machine; make sure the pump is on.
2. Or contact your dealer.
4 EE 4
failure connection due to loose wire terminal of PROT2 on the PC board
Contact your dealer.
5 PP 1 Pool water temp sensor failure Contact your dealer. 6 PP 2 Heat only type: Exhaust temp sensor failure Contact your dealer. 7 PP 3 Heating coil pipe temp sensor failure Contact your dealer. 8 PP 4 Gas return temp sensor failure Contact your dealer. 9 PP 5 Air temp sensor failure Contact your dealer. 10 PP 6 Compressor exhaust overload protection Contact your dealer.
11 PP 7
When the temperature 7, auto stop for protection (Not Failure );
Machine Auto-protection
12
EE8/888 /Messy Code
Communication Failures Contact your dealer.
Loading...