Technical data
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 V AC ±15% 50/60 Hz
Max. pre-fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 A
Built-in circuit breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-pole, 16 A
Output relay . . . . . . . . . . . . . . . . . . . . . . . .Make contact - SPST - NO
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Max. 16 A / 3600 W
Control principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PWM regulation
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+0/+40°C
- control voltage signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 V AC
Frost protection temperature . . . . . . . . . . . . . . . . . . . . . .5°C absolute
- control voltage signal via rectifier diode . . . . . . . . . . . . . . .230 V AC
Sensor fault protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-20°C
Ambient operating temperature . . . . . . . . . . . . . . . . . . . . . . .0/+40°C
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .H/84, W/84, D/40 mm
Enclosure rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP 21
The thermostat is maintenance free.
Classification
The product is a Class II appliance (with reinforced insulation) and
must be connected as follows:
Term. 1: Live (L1) 230 V ±15%, 50/60 Hz
Term. 2: Neutral (L2)
Term. 3–4: Max. load 16 A, 3600 W
Heat Mat’s TPS30 electronic thermostat is designed for installation in
a standard wall box. The thermostat allows the required temperature
to be set within the range 0-40C. An LED indicates whether the
heating is active. The thermostat is suitable for a standard UK single
gang light switch box.
PRODUCT PROGRAM
TPS-345-0030 White (OTD2-1999-HM)
TPS-COL-0030 Silver (OTD2-1999-HMB5)
CE MARKING
Applied standards
EN 61000-6-3, EN 61000-6-2, EN 60 730-1 and EN 60730-2-9.
The product may only be used if the complete installation complies
with current directives.
The final electrical connection should be completed by a suitably
qualified person.
If the product has been damaged in any way, e.g. during transport, it
must be inspected and checked by a suitable qualified individual
before being connected to the power supply.
The product carries a manufacturer's warranty if installed in
accordance with these instructions and applicable regulations.
Type TPS-30 with room and floor sensor English