Eco-Choice Insert Wood Burner Installation Instructions
Model:
WINS18-AU
INSTALLATIONS TO COMPLY WITH AS/NZS2918:2001
AND WILL REQUIRE A BUILDING CONSENT
IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these
instructions may result in a re hazard and will void the warranty.
• Fig. 3,4,5,6, 7 and Table 1,2,3,4 relate to installations with tested ue systems; as per AS/NZS
2918:2001 - Appendix F, with a ceiling angle between 0° - 30° inclusive.
• For installations with a ceiling angle greater than 30°, refer to Fig. 7 & 8 and AS/NZS 2918:2001
4.6.3(b)
• Ceiling Plate may vary in size depending on ceiling angle. Please specify ceiling pitch prior to
ordering the ceiling plate.
• Heatilator Eco Choice series wood burner’s are tested and approved to the N.Z. National Environmental Standards;
WINS18-AU Eco-Choice Hardwood Certied
Particulate Emissions = 1.0 g/kg Space Heating Efciency = 77%
Page 1
7065-144A
April 7, 2014
WS Series Wood Burner
OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD
(WHEN TESTED IN ACCORDANCE TO AS/NZS 4012:1999)
77%
AVERAGE PARTICULATE EMISSION FACTOR BURNING HARDWOOD
(WHEN TESTED IN ACCORDANCE TO AS/NZS 4013:1999)
1.0g/kg
MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD
7.7 kw
APPROVED FUEL
BURN ONLY HARDWOOD WITH A MOISTURE CONTENT LESS THAN 25% (dry basis).
WETBACK - ALL MODELS
MANUFACTURED BY
Wetbacks are NOT an approved option and must not be tted.
NOTE: Performance may vary from test values depending on actual operating conditions.
1.5” x .375 Barcode Label
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
2014
2015 2016
INSTALLATION
DATE
ECO CHOICE WOODFIRE COMPLIANCE LABEL
7065-143
This appliance has been TESTED TO AS/NZS4013:1999 for Hardwood by HRL Technology Report # HCMG/14/007
Date tested: February 2014
MODEL ECO CHOICE WINS18 WOOD HEATER
PERFORMANCE MAY VARY FROM TEST
VALUES DEPENDING ON ACTUAL OPERATING
CONDITIONS.
room for .14 x .875” S/N
SERIAL NO.
007067
Hearth & Home Technologies welcomes you to our tradi-
tion of excellence! In choosing a Heatilator appliance, you
have our assurance of commitment to quality, durability, and
performance.
This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world’s most
advanced technology to achieve the optimum operation of
our stoves, inserts and replaces. And yet we are old-fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and surfaces are hand-nished for lasting
beauty and enjoyment. Our pledge to quality is completed
as each model undergoes a quality control inspection.
We wish you and your family many years of enjoyment in
the warmth and comfort of your hearth appliance. Thank
you for choosing Heatilator.
Page 2
7065-144A
April 7, 2014
Heatilator WS18 Wood Burner Dimensions
24-1/4 in.
(616mm)
15-11/16 in.
(398mm)
9-7/16 in.
(240mm)
33-1/4 in.
(845mm)
10-1/2 in.
(267mm)
10-1/2 in.
(267mm)
5-3/16 in.
(132mm)
21-1/16 in.
(534mm)
6-1/16 in.
(154mm)
4-1/2 in.
(114mm)
7-5/16 in.
(186mm)
20 in.
(508mm)
B
WS Series Wood Burner
A
Figure 3.1 - Front View
Surround Sizes
A B
SP-WINS18-STD 1092mm 787mm
SP-WINS18-LRG 1295mm 864mm
Figure 3.2 -Top View
April 7, 2014
Figure 3.3 - Side View
7065-144A
Page 3
WS Series Wood Burner
FLOOR PROTECTOR
Heatilator WINS18 does require a insulating Floor Protector minimum 900mm deep, 800mm wide
and 75mm thick (clay bricks), as they are tested and comply with the minimum Floor Protector
requirements of AS/NZS 2918:2001.
Note:
▪ The minimum Floor Protector sizes are specied in the clearance chart, see Fig. 3 and 4.
▪ A Floor Protector can include ceramic tiles with grouted joints xed directly onto a wooden oor or
a sheet of toughened glass, panel steel or any other non combustible material laid directly onto a
wooden oor.
▪ If installed directly onto a concrete slab, the concrete slab can be considered as the oor
protector,but must maintain the minimum measurement listed.
MINIMUM CLEARANCES
Fig. 3
Mantel
1050mm
250mm
NOTE: HEAT SHIELD REQUIREMENTS FOR HEAT SENSITIVE WALLS
Clearances may be reduced by provision of an appropriately located heat shield refer to
AS/NZS 2198:2001 3.2.3 TABLE 3.1
Page 4
300mm
7065-144A
April 7, 2014
MINIMUM CLEARANCES (CONT.)
Fig. 4
WS Series Wood Burner
800mm
Mantle
uprights
must be
less than
50mm thick
April 7, 2014
7065-144A
Page 5