Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to this manual. For assistance or additional information, consult a qualified installer,
service agency or the gas supplier.
07/0317789 Rev H1
WARNING!
NA SERIES INSTALLATION INSTRUCTIONS
TABLE OF CONTENTS
Design and Installation Considerations .......................................................................................................... 3
A. Listings and Code Approvals .......................................................................................................................... 4
B. Description of the Fireplace System ............................................................................................................... 4
C. Fireplace System Components ....................................................................................................................... 5
D. Pre-Installation Preparation .......................................................................................................................... 10
E. Chimney Requirements ................................................................................................................................ 12
F. Installation of Fireplace ................................................................................................................................. 15
G. Constructing a Chase ................................................................................................................................... 22
H. Operating Instructions ................................................................................................................................... 25
Index ............................................................................................................................................................. 31
Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insulation will produce an odor when the fireplace is used.
WARNING!
This appliance is tested and listed for use only with the optional accessories listed in these instructions. Use
of optional accessories not specifically tested for this appliance could void the warranty and/or result in a
safety hazard.
Safety Precautions
1. Please read these installation instructions completely before beginning installation procedures. Failure to follow them
could cause a fireplace malfunction resulting in serious injury and/or property damage.
2. Always check your local building codes prior to installation. The installation must comply with all local, regional, state
and national codes and regulations.
3. An adequate supply of replacement combustion air from outside the house must be available to the fire for the
fireplace to operate properly. To achieve this, the use of the optional outside air kit is highly recommended.
In the event the home is unusually tightly sealed, the optional combustion air kit may not provide all the air required
to support combustion. Hearth & Home Technologies is not responsible for any smoking or related problems that may
result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that adequate
combustion air has been provided for the fireplace.
4. The fireplace must be installed with the Hearth & Home Technologies SL Series Chimney System.
The chimney system must always terminate outside the building. Be sure to follow all chimney specifications given in
these installation instructions.
5. NEVER leave children unattended when there is a fire burning in the fireplace.
6. This fireplace is built for solid fuel only. NEVER use gasoline, gasoline type lantern fuel, kerosene, charcoal light fluid,
or similar liquids in this fireplace. Keep any flammable liquids a safe distance from the fireplace.
7. DO NOT use chimney cleaners or flame colorants in your fireplace.
8. The flue damper must be open at all times when the fireplace is in use.
9. While servicing this fireplace, always shut off any electricity or gas to the fireplace. This will prevent possible electric
shock or burns. Also, make sure the fireplace is completely cooled before servicing.
10. To ensure a safe fireplace system and to prevent the build up of soot and creosote, inspect and clean the fireplace
and chimney prior to use and periodically during the burning season. See Maintenance Instructions in this manual
for cleaning instructions.
217789 Rev H07/03
NA SERIES INSTALLATION INSTRUCTIONS
DESIGN AND INSTALLATION CONSIDERATIONS
When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern
construction techniques can create conditions that may not allow your chimney to draft properly. This may result in smoke
spillage from your fireplace, as well as cause other combustion appliances to operate incorrectly.
Tightly sealed construction is important for energy efficiency. Unfortunately, a great deal of effort has been directed to
tightening up sidewall construction, while considerably less attention has been paid to tightening upper portions of the
warm air envelope (insulated ceilings). This has increased the Stack Effect, a condition that increases the negative
pressure generated by the structure. This negative pressure will directly affect the drafting performance of a fireplace
chimney. To minimize the negative pressure generated by stack effect, make certain that all duct work installed in the attic
spaces is sealed airtight. Minimize the number of recessed light fixtures installed in the insulated ceiling, and use sealed
recessed light fixtures. Finally, make certain the whole house fans and attic access panels are tightly sealed. These are
important design considerations that must be observed during the design and construction stage of the home.
If you desire to put a fireplace in your basement, we recommend that you consider a direct vent gas fireplace. Basements
always have a significant negative air pressure that causes the fireplace system to be more susceptible to smoke spillage
and cold flue back drafting. Since direct vent gas fireplaces are sealed, they are not affected by the negative pressure that
exists in basements.
Finally, woodburning fireplaces perform best when their chimney (roof termination) is located on the upper half of the roof,
especially when cathedral ceilings are present. Chimneys that are located on the lower half of the roof realize what is
known as lazy flue and will not draft as well as a chimney that is located in the upper portion of the roof. The reason for
this is that the stack effect generated by the overall height of the living spaces inside the house will exceed the draft
generated by the chimney system. If you desire to place a woodburning fireplace in a location where the termination cap
would be located on the lower half of a roof, such as on an outside wall at the base of a cathedral ceiling, we recommend
that you consider using a direct vent gas fireplace. This will assure the homeowner a fireplace that operates correctly.
These properties do not affect just your woodburning factory built fireplace. They can cause any woodburning fireplace as
well as any conventionally vented (B-vent) gas appliance to operate improperly. Careful planning at this stage of your
project will ensure satisfaction with the operation of your fireplace once it is completed.
07/0317789 Rev H3
NA SERIES INSTALLATION INSTRUCTIONS
A. LISTINGS AND CODE APPROVALS
This fireplace system has been tested and listed in
accordance with UL127 and ULC-S610 standards, and has
been listed by Underwriters Laboratories Inc. for installation
and operation in the United States and Canada as described
in this manual.
This fireplace has been tested and listed for use with the
optional components listed on page 5. These optional
components may be purchased separately and installed at
a later date. However, installation of an outside air kit will
require significant reconstruction, and should be installed
at the time of the initial fireplace installation.
WARNING!
This fireplace and its components are designed to be installed and operated as a system. Any alteration to or
substitution for items in this system, unless allowed by these installation instructions, will void the Underwriters Laboratories listing and may void the product warranty. It may also create a hazardous installation. Read
through these instructions thoroughly before starting your installation and follow them carefully throughout
your project.
Check with your local building code agency prior to installing
this fireplace to ensure compliance with local codes,
including the need for permits and follow-up inspections. If
you need assistance during installation, please contact your
local dealer or the Heatilator Technical Services
Department, Hearth & Home Technologies, 1915 W.
Saunders St., Mt. Pleasant, Iowa 52641 (1-800-843-2848).
Heatilator® is a registered trademark of Hearth & Home
Technologies Inc., Division, HON INDUSTRIES.
B. DESCRIPTION OF THE FIREPLACE SYSTEM
1. The Heatilator fireplace system consists of the following:
a. Fireplace/Integral Grate
b. Refractory
c. Chimney Termination Cap
d. Chimney System
e. Hearth Extension
2. Optional Components Include:
a. Glass Doors
b. Chimney Air Kit
c. Outside Combustion Air System
d. Fan Kit
Note: Illustrations used throughout these instructions
reflect typical installations and are for design purposes
only. Actual installation may vary slightly due to individual design preferences. However, minimum and maximum clearances must be maintained at all times.
The illustrations and diagrams used throughout these
installation instructions are not drawn to scale.
The following pictures show only those chimney components which may be safely used with this fireplace.
#golataC:noitpircseD
A4KACtiKriAyenmihC
4DIriAedistuO/tcuDdetalusnI
4DUriAedistuO/tcuDdetalusninU
603LSgnol"6-noitceSyenmihC
213LSAN/213LSgnol"21-noitceSyenmihC
813LSgnol"81-noitceSyenmihC
423LSgnol"42-noitceSyenmihC
633LSAN/633LSgnol"63-noitceSyenmihC
843LSAN/843LSgnol"84-noitceSyenmihC
3LSrezilibatSyenmihC
513LS°51-nruteR/tesffOyenmihC
033LSAN/033LS°03-nruteR/tesffOyenmihC
833SFAN/833SF
933SF°51-potseriF
043SF°03-potseriF
8SA"42,dleihSnoitalusnIcittAthgiartS
778BJdnaBtnioJyenmihC
678BCtekcarByenmihC
073FRAN/073FRhctiP21/6ottalF-gnihsalFfooR
173FRhctiP21/21ot21/6-gnihsalFfooR
443RTAN/443RTpaCnoitanimreTdnuoR
243RTpaCnoitanimreTgnipocseleTdnuoR
573TSpaCnoitanimreTerauqS
543STpaCnoitanimreTerauqS
P543STdetniaP-paCnoitanimreTerauqS
53TCpoTesahC
33SDL'3x'3-duorhSevitaroceD
64SDL'6x'4-duorhSevitaroceD
thgiartS-potseriF
07/0317789 Rev H7
Chimney Sections
#golataCAB
603LS"6"¾4
213LS"21"¾01
213LSAN"21"¾01
813LS"81"¾61
423LS"42"¾22
633LS"63"¾43
633LSAN"63"¾43
843LS"84"¾64
843LSAN"84"¾64
=AhtgnellautcA
=Bfohtgnel(htgnelevitceffE
NA SERIES INSTALLATION INSTRUCTIONS
SL3 - Chimney StabilizerSL330/NASL330
Offset/Return
sahtiretfatrapyenmihc
)rehtonaotdeppansneeb
Firestop Spacer
#golataCAB
833SF°0"½41
833SFAN°0"½41
933SF°5181
043SF°03"32
CB876
Chimney Bracket
RF370/NARF370 - Roof Flashing
Flat to 6/12 Pitch
3
/8"
JB877
Joint Band
RF371 - Roof Flashing
6/12 to 12/12 Pitch
AS8
Straight Attic
Insulation Shield
817789 Rev H07/03
NA SERIES INSTALLATION INSTRUCTIONS
LDS33 (3 x 3)
LDS46 (4 x 6)
Decorative Shroud
ST375
Square
Termination Cap
TR344/NATR344
Round
Termination Cap
TS345/TS345P
Square
Termination Cap
TR342
Round Telescoping
Termination Cap
CT35
Chase Top
07/0317789 Rev H9
CAK4A
Chimney Air Kit
NA SERIES INSTALLATION INSTRUCTIONS
D. PRE-INSTALLATION PREPARATION
1. Fireplace Locations and Space Requirements
Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a
room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 2.
Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations
of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the
fireplace. Consideration should be given to these factors before deciding on a location.
CLEARANCES!
A minimum ½ air clearance must be maintained
at the back and sides of
the fireplace assembly.
Chimney sections at any
level require a 2 minimum air space clearance
Figure 2 - Fireplace Locations
Figures 3 and 4 show two typical installations assuming an outside air kit is
being used. Therefore, an allowance must be made for 90° bends. Less space
is required when ducting goes directly outside without forming elbows.
between the framing and
chimney section.
tuohtiW
riaedistuO
htiW
riAedistuO
#.taCAB
63AN"24"54
24AN"84"15
Figure 3
Installation Along a Wall or an Exterior Chase
These are rough framing
dimensions only.
riAedistuOtuohtiWrohtiW
#.taCABCDE
63AN"24273/4"633/8"515/8"153/8"
3
24AN"8487
Figure 4 - Corner Installation
/4"933/8"715/8"553/8"
WARNING!
Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous.
Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the
roofing where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will
reduce the possibility of fireplace smoking or air flow reversal.
WARNING!
To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers