Heatilator CD4236MR, CD4236MLR, CD4236MILR, CD4842MLR, CD4842MIR Owner's Manual

...
Models: CD4236MR CD4842MR CD4236MLR CD4842MLR CD4236MIR CD4842MIR CD4236MILR CD4842MILR Direct Vent Gas Appliance
Owner’s Manual
Installation and Operation
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating and maintenance instructions included.
Read, understand and follow these instructions for safe installation and operation.
WARNING
If the information in these instruc­tions is not followed exactly, a re may result causing property damage, personal injury, or death.
• Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance.
• What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fi re department.
• Installation and service must be performed by a qualifi ed installer, service agency, or
the gas supplier.
DO NOT
DISCARD
Leave this manual with party responsible for use and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as appliance.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other ammable materials.
• Keep clothing, furniture, draperies and other combustibles away.
This appliance has been supplied with an integral barrier to prevent direct contact with the fi xed glass panel. Do NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.
¨
This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for
Installation in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated on the rating plate.
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 1
In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter;
See Table of Contents for location of additional Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be performed by qualifi ed personnel. Hearth & Home Technologies suggests NFI certifi ed or factory-trained professionals, or technicians supervised by an NFI certifi ed professional.
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
Congratulations
Congratulations on selecting a Heatilator gas appliance—an elegant and clean alternative to wood burning appliances. The Heatilator gas appliance you have selected is designed to provide the utmost in safety, reliability, and effi ciency.
As the owner of a new appliance, you’ll want to read and carefully follow all of the instructions contained in this owner’s
The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems.
Your new Heatilator gas appliance will give you years of durable use and trouble-free enjoyment. Welcome to the Heatilator family of appliance products!
manual. Pay special attention to all cautions and warnings.
This owner’s manual should be retained for future reference. We suggest you keep it with your other important documents and product manuals.
We recommend that you record the following pertinent
Homeowner Reference Information
information about your appliance:
Model Name: Date purchased/installed:
Serial Number: Location on appliance:
Dealership purchased from: Dealer phone:
Notes:
Listing Label Information/Location
The model information regarding your specifi c appliance can be found on the rating plate located in the control area of the appliance.
Serial #
XXXXXXXXX
XXXX
CERTIFIED
FOR CANADA
CERTIFIÉ POUR LE
CANADA
Orifice Size
Model #
Gas Type
Hearth & Home Technologies Inc
1915 W. Saunders Street Mt. Pleasant, IA 52641
ANSI Standard
MODEL MFG. DATE MODÈLE DATE DE FAB.
GAS TYPE/TYPE DE GAZ NATURAL/NATUREL PROPANE ALTITUDE 0-2000 2000-4000 FT/PI 0-2000 2000-4000 FT/PI MAX INPUT/DÉBIT XX,XXX XX,XXX BTUH XX,XXX XX,XXX BTUH MIN INPUT/DÉBIT XX,XXX XX,XXX BTUH XX,XXX XX,XXX BTUH MANIFOLD PRESSURE/PRESSION TUBULAIRE MAX. XX IN. W.C./C. D'EAU XX IN. W.C./C. D'EAU MIN. XX IN. W.C./C. D'EAU XX IN. W.C./C. D'EAU MIN. INLET PRESS. XX IN. W.C./C. D'EAU 1XX IN. W.C./C. D'EAU FOR THE PURPOSE OF INPUT ADJUSTMENT PRESS. MIN. D'ALIMENTATION ORIFICE SIZE DIAM. DE L'INJECTEUR XX/XX DIA. in./mm XX/XX DIA. in./mm
XXXXXX
SERIAL NO. DE SÉRIE
LESS THAN/MOINS DE 3 AMPÈRES., 115V., 60 Hz
DO NOT REMOVE OR COVER THIS LABEL. VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUEL. FOYER À GAZ À ÉVACUATION - NE DOIT PAS ÊTRE UTILISÉ AVEC UN COMBUSTIBLE SOLIDE.
2 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
Table of Contents
1 Listing and Code Approvals 4
A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . 4
B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . 4
C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . .4
E. Non-Combustible Materials . . . . . . . . . . . . . . . . . . . . .4
F. Combustible Materials . . . . . . . . . . . . . . . . . . . . . . . . . 4
G. Requirements for the
Commonwealth of Massachusetts. . . . . . . . . . . . . . . . 5
2 Getting Started 6
A. Design and Installation Considerations . . . . . . . . . . . .6
B. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . 6
C. Inspect the Appliance and Components . . . . . . . . . . . 6
3 Framing and Clearances 7
A. Select Appliance Location . . . . . . . . . . . . . . . . . . . . . .7
B. Construct the Appliance Chase . . . . . . . . . . . . . . . . . . 8
C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4 Termination Locations 11
A. Vent Termination Minimum Clearances . . . . . . . . . . . 11
5 Vent Information and Diagrams 14
A. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
B. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
C. Measuring Standards. . . . . . . . . . . . . . . . . . . . . . . . . 14
D. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
E. Installing Vertical Termination Baffl e . . . . . . . . . . . . . 24
6 Vent Clearances and Framing 25
A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . 25
B. Wall Penetration Framing . . . . . . . . . . . . . . . . . . . . .25
C. Install the Ceiling Firestop . . . . . . . . . . . . . . . . . . . . . 26
D. Install Attic Insulation Shield . . . . . . . . . . . . . . . . . . . 27
7 Appliance Preparation 28
A. Convert from Top Vent to Rear Vent . . . . . . . . . . . . . 28
B. Securing and Leveling the Appliance . . . . . . . . . . . .32
8 Installing Vent Pipe 33
A. Assemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . 33
B. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . 36
C. Install the Heat Shield and
Horizontal Termination Cap . . . . . . . . . . . . . . . . . . . .37
D. Install Roof Flashing and Vertical Termination Cap . . 39
E. Assemble and Install Storm Collar . . . . . . . . . . . . . . 40
9 Gas Information 41
A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
B. Gas Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . .42
10 Electrical Information 43
A. Recommendation for Wire . . . . . . . . . . . . . . . . . . . . . 43
B. Connecting to the Appliance . . . . . . . . . . . . . . . . . . . 43
C. Intellifi re Ignition System Wiring . . . . . . . . . . . . . . . .43
D. Standing Pilot Ignition System Wiring . . . . . . . . . . . . 44
E. Junction Box Installation . . . . . . . . . . . . . . . . . . . . . . 45
F. Wall Switch Installation for Fan (Optional) . . . . . . . . . 45
11 Finishing 46
A. Mantel Projections . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
12 Appliance Setup 47
A. Remove Clean Face Components . . . . . . . . . . . . . . 47
B. Remove Glass Assembly. . . . . . . . . . . . . . . . . . . . . . 47
C. Remove the Shipping Materials. . . . . . . . . . . . . . . . . 47
D. Clean the Appliance. . . . . . . . . . . . . . . . . . . . . . . . . .47
E. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
F. Install the Refractory . . . . . . . . . . . . . . . . . . . . . . . . .47
G. Lava Rock, Vermiculite, Rockwool Placement . . . . .47
H. Log Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
I. Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
J. Install Trim . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
K. Install Clean Face Components . . . . . . . . . . . . . . . . 49
L. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
13 Operating Instructions 52
A. Before Lighting Appliance . . . . . . . . . . . . . . . . . . . . . 52
B. Lighting the Appliance . . . . . . . . . . . . . . . . . . . . . . . .53
C. After the Appliance is Lit . . . . . . . . . . . . . . . . . . . . . . 55
D. Frequently Asked Questions . . . . . . . . . . . . . . . . . . .55
14 Troubleshooting 56
A. Standing Pilot Ignition System . . . . . . . . . . . . . . . . . . 56
B. Intellifi re Ignition System . . . . . . . . . . . . . . . . . . . . . . 58
15 Maintaining and Servicing the Appliance 60
16 Reference Materials 62
A. Appliance Dimension Diagram . . . . . . . . . . . . . . . . .62
B. Vent Components Diagrams . . . . . . . . . . . . . . . . . . . 63
C. Service Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
D. Optional Components . . . . . . . . . . . . . . . . . . . . . . . . 78
E. Limited Lifetime Warranty . . . . . . . . . . . . . . . . . . . . . 83
F. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . .84
Note: An arrow (¨) found in the text signifi es change in content.
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 3
1
Listing and Code Approvals
1
A. Appliance Certifi cation
MODELS: CD4236MR, CD4236MLR,CD4236MIR, CD4236MILR, CD4842MR, CD4842MLR, CD4842MIR, CD4842MILR
LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Appliance STANDARD: ANSI Z21.88-2005/CSA2.33-2005/UL307B
This product is listed to ANSI standards for “Vented Gas Fireplace Heater” and applicable sections of “Gas Burn­ing Heating Appliances for Manufactured Homes and Rec­reational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either
supplemental room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.
B. Glass Specifi cations
Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defi ned by the Consumer Product Safety Commission (CPSC). The tempered glass has been tested and certifi ed to the requirements of ANSI Z97.1 and
CPSC 16 CFR 1202 (Safety Glazing Certi cation Council SGCC# 1595 and 1597. Architectural Testing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Section
1201.5 “Certi cation and labeling requirements” which refers
to 15 U.S. Code (USC) 2063 stating “…Such certifi cate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”
Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.
Note: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.
C. BTU Specifi cations
Caliber CD Mesh Series CD4236M CD4842M
Standing Pilot or IPI
Max/Min Input Rate (NG) 30,000/20,000 33,000/22,000
Orifi ce Size (NG) .104 in./2.64 mm .109 in./2.77 mm
Max/Min Input Rate (LP) 29,500/20,000 32,500/20,500
Orifi ce Size (LP) .065 in./1.65 mm .067 in./1.70 mm
D. High Altitude Installations
U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.
When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang­ing the existing burner orifi ce to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop­er orifi ce size, check with the local gas utility.
If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.
WARNING
Do NOT use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
E. Non-Combustible Materials
Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136, Stan-
dard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750° C, shall be considered non-combus-
tible materials.
F. Combustible Materials
Materials made of or surfaced with wood, compressed pa­per, plant fi bers, plastics, or other material that can ignite and burn, whether fl ame proofed or not, or whether plastered or unplastered shall be considered combustible materials.
4 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
NOTE: The following requirements reference various
G. Requirements for the Commonwealth of Massachusetts
Massachusetts and national codes not contained in this document.
G. Requirements for the Commonwealth of Massachusetts
For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, includ­ing but not limited to decks and porches, the following requirements shall be satisfied:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon mon­oxide detector with an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
Signage
A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT
DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUC­TIONS”.
Inspection
The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installa­tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and
• Product Approved side wall horizontally vented gas
fueled equipment installed in a room or structure sepa rate from the dwelling, building or structure used in whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
Detailed instructions for the installation of the venting
system design or the venting system components; and
A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satis­fied by the manufacturer:
• The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and
• The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equip ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
See Gas Connection section for additional Common­wealth of Massachusetts requirements.
-
-
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 5
2
Getting Started
2
A. Design and Installation Considerations
Heatilator direct vent gas appliances are designed to op­erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and national codes and regulations.
• Consult insurance carrier, local building, fire offi cials or authorities having jurisdiction about restrictions, installation inspection, and permits.
When planning an appliance installation, it’s necessary to determine the following information before installing:
• Where the appliance is to be installed.
• The vent system confi guration to be used.
• Gas supply piping.
• Electrical wiring.
• Framing and fi nishing details.
• Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.
C. Inspect the Appliance and Components
WARNING
Inspect appliance and components for damage. Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
• Carefully remove the appliance and components from the packaging.
• The vent system components and trim doors are shipped in separate packages.
• The gas logs may be packaged separately and must be eld installed.
• Report to your dealer any parts damaged in shipment, particularly the condition of the glass.
• Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefi t.
WARNING
Keep appliance dry.
• Mold or rust may cause odors.
• Water may damage controls.
B. Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Reciprocating saw Framing material
Pliers Hi temp caulking material
Hammer Gloves
Phillips screwdriver Framing square
Flat blade screwdriver Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level Manometer
Voltmeter Tape measure
Non-corrosive leak check solution
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
One 1/4 in. female spade connection (for optional fan)
WARNING
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent system component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
6 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
3
Framing and Clearances
3
Note:
• Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design preference.
A. Select Appliance Location
When selecting a location for your appliance it is important to consider the required clearances to walls (See Figure 3.1).
WARNING
Fire Risk
Provide adequate clearance:
• Around air openings.
• For service access.
Locate appliance away from traffi c areas.
Note: For actual appliance dimensions refer to Section 16.
1/2 in. (13 mm) min.
appliance to
combustibles
B
F
B
D
A
Top Vent
One 90° elbow
Horiz Term
Rear Vent
One 90° elbow
Vert Term
A
C
Drywall
In addition to these framing dimensions, also reference the following sections:
• Clearances and Mantel Projections (Section 3.C.)
• Vent Clearances and Framing (Section 6)
No elbows
Horiz Term
A G
Alcove
Installation
A
H
Rear Vent
Two 90° elbows
Horiz Term
C
1/2 in. (13 mm) min.
Rear vent
One 45° elbow
Horiz Term
E
appliance to
combustibles
A
A
1 in. (25 mm) min.
pipe to
combustibles
E
I
1 in. (25 mm) min.
pipe to combustibles
F
Model # A B C D E F G H I
CD4236 in. 42 50-5/8 23-1/2 71-5/8 50-5/8 52-5/8 43 48 59-3/4
mm 1067 1286 597 1819 1286 1337 1092 1220 1518
CD4842 in. 48 55-1/4 23-1/2 78-1/4 55-1/4 55-1/4 49 48 59-3/4
mm 1219 1403 597 1988 1403 1403 1245 1220 1518
Figure 3.1 Appliance Locations
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 7
I
B. Construct the Appliance Chase
A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not required to be, installed inside a chase.
Construction of the chase may vary with the type of build­ing. These instructions are not substitutes for the require­ments of local building codes. Local building codes MUST be checked.
Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside building envelope in any manner.
WARNING
Fire Risk
• Construct chase to all clearance specifi cations in manual.
• Locate and install appliance to all clearance specifi cations in manual.
Walls, ceiling, base plate and cantilever fl oor of the chase should be insulated. Vapor and air infi ltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infi ltration may be an issue, the inside surfaces may be sheetrocked and taped (or the use of an equivelent method) for maximum air tightness.
To further prevent drafts, the ceiling fi restops should be caulked with high temperature caulk to seal gaps. Gas line holes and other openings should be caulked with high tem­perature caulk or stuffed with unfaced insulation. If the appli-
8 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
C. Clearances
WARNING
Fire Risk Odor Risk
1/2 in. (13 mm)
Combustible flooring may be installed next to the front of the appliance.
30 in.
(762 mm)
to ceiling
0 in. TO LEVEL
OF STANDOFFS
1/2 in. (13 mm)
Drywall
0 in.
• Install appliance on hard metal or wood surfaces extending full width and depth of appliance.
• Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.
Note: I f t he inside of t he framed cavit y is to be fi nished, the framing dimensions must include the fi nished sur fac e. If dry wall i s t o be at t a c h e d to the rear wal l , the depth must be measured from the drywall surface.
D
36 in.
(914 mm)
Combustible Object
Figure 3.2 Clearances to Combustibles
B
0 in.
A
Rough
Opening
Model
CD4236 in. 42 38-3/4 23-1/2 10
CD4842 in. 48 38-3/4 23-1/2 10
(Width)
mm 1067 984 597 254
mm 1219 984 597 254
B
Rough
Opening
(Height)
Rough
Opening
(Depth)
A
C
Rough
Opening
(DVP Pipe)
C
D
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 9
ance is being installed on a cement slab, a layer of plywood may be placed underneath to prevent conducting cold up into
30 in. minimum
to ceiling
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
6-1/4
5-1/2
5
7-3/4
7
9-1/4
8-1/2
Measured from top of hood (in inches)
10-3/4
10
12-1/4
11- 1/2
14-1/2
13-3/4
13
16
15-1/4
Figure 3.3 Clearances to Mantels or Other Combustibles Above Appliance
Top o f Appliance
A
B
Mantel Leg or
Perpendicular Wall
1 in. (25 mm) min.
A
to perpendicular wall 3-1/2 in. (89 mm) min.
B
from fireplace opening to perpendicular wall
Figure 3.4 Clearances to Perpendicular Wall
Drywall
48 in.
(1219 mm)
max.
WARNING
Fire Risk
• Comply with all minimum clearances to combustibles as specifi ed.
• Framing or fi nishing material used on the front of, or in front of, the appliance closer than the minimums listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).
Failure to comply may cause fi re.
10 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
4
Termination Locations
4
A. Vent Termination Minimum Clearances
WARNING
Fire Risk Explosion Risk
Inspect external vent cap regularly.
• Ensure no debris blocks cap.
• Combustible materials blocking cap may ignite.
• restricted air flow affects burner operation.
WARNING
Fire Risk Explosion Risk
Maintain vent clearance to combustibles as specifi ed.
• Do not pack air space with insulation or other materials.
Failure to keep insulation or other materials away from vent pipe may cause fi re.
Measure vertical clearances from this surface
Measure horizontal clearances from this surface.
(see Figure 4.4 for specifi c clearances)
Figure 4.1 Clearances from Cap Surfaces
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 11
Figure 4.2 specifi es minimum vent heights for various pitched roofs.
Horizontal overhang
24 in. min.
(610 mm)
20 in.
(508 mm)
Lowest
Vertical wall
Discharge
Termination
Opening
Cap
Storm Collar
X
12
Roof
Flashing
Roof Pitch is X / 12
H (min.) - Minimum height from roof to lowest discharge opening.
Roof Pitch H (Min.) Ft. Roof Pitch H (Min.) Ft.
Flat to 6/12 1.0* Over 11/12 to 12/12 4.0 Over 6/12 to 7/12 1.25* Over 12/12 to 14/12 5.0 Over 7/12 to 8/12 1.5* Over 14/12 to 16/12 6.0 Over 8/12 to 9/12 2.0* Over 16/12 to 18/12 7.0 Over 9/12 to 10/12 2.5 Over 18/12 to 20/12 7.5 Over 10/12 to 11/12 3.25 Over 20/12 to 21/12 8.0
* 3 ft. minimum in snow regions
Figure 4.2 Minimum Height from Roof to Lowest Discharge Open­ing
Direct Vent Gas, Wood or Fuel
Oil Termination
20 in.
(508 mm)
(minimum) to
Perpendicular
Wall
(gas only)
(457 mm)
Gas
Termination
18 in.
A
B
Termination Caps Staggered Height
A Gas Termination Wood or Fuel Oil Termination B 6 in.
(152 mm) min. 20 in. (508 mm) min.
Figure 4.3 Multiple Vertical Termination
Termination Caps Same Height
Direct Vent Gas, Wood or Fuel
Oil Termination
20 in.
(508 mm)
(minimum) to
Wood or
Gas Termination
* If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instruc­ tions supplied with the decorative cap cover.
20 in. min. *
(508 mm)
Perpendicular
Wall
(gas only)
12 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
D
E
B
L
C
V
V
B
F
V
B
V
V
B
X
A
J
Fixed
Fixed
Closed
M
V
K X
RES TRI CTION ZO NE (TE RMI NATION NOT ALL OWE D)
AIR SU PPLY IN LET
X
GAS ME TER
V
TERMINATION CAP
H
B
Openable
Fix ed
Clo sed
V
V
O
N
A
V
V
G
Closed
TERMINATION CAP
Openable
Fixed
Closed
Measure vertical clearances
from this surface
T
Measure horizontal clearances
Alcove Clearances
from this surface.
Dimension Descriptions
A Clearance above the ground, a veranda, porch, deck or balcony - 12
in. (30 cm) minimum. *
B Clearance to window or door that may be opened – 10,000 BTUs
or less, 6 in. (15 cm) minimum; 10,000-50,000 BTUs, 9 in. (23 cm) minimum; over 50,000 BTUs, 12 in. (30 cm) minimum. *
C Clearance to permanently closed window – 12 in. (30 cm) minimum
- recommended to prevent condensation on window.
D Vertical clearance to ventilated soffi t located above the termination
within a horizontal distance of 2 ft (60 cm) from the centerline of the termination – 18 in. (46 cm) minimum. **
E Vertical clearance to unventilated soffi t - 12 in. (30 cm) minimum. **
F Clearance to outside corner - 6 in. (15 cm) minimum.
G Clearance to inside corner - 6 in. (15 cm) minimum.
H Not to be installed above a meter/regulator assembly within 3 ft (90
cm) horizontally* from the center line of the regulator (Canada only)
I Clearance to service regulator vent outlet – 3 ft (.91 m) U.S. minimum
and 3 ft (.91 m) Canada minimum. *
J Clearance to non-mechanical air supply inlet into building or the
combustion air inlet to any other appliance – 9” (23 cm) U.S. minimum and 12 in. (30 cm) Canada minimum. *
K Clearance to mechanical air supply inlet - 3 ft (.91 m) U.S. minimum
and 6 ft (1.8 m) Canada minimum. *
L Clearance above a paved sidewalk or paved driveway located on public
property - 7 ft (2.1 m) minimum.
A vent may not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both dwellings.
M Clearance under veranda, porch, deck or balcony - 12 in. (30 cm)
minimum. * Recommended 30 in. (76 cm) for vinyl or plastic.
Only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the fl oor. *
N Vertical clearance between two horizontal termination caps – 12 in. (30
cm) minimum.
O Horizontal clearance between two horizontal termination caps – 12 in.
(30 cm) minimum.
I
GAS METER
AIR SUPPLY INLET
Q
P
V
R
S
RESTRICTION ZONE (TERMINATION NOT ALLOWED)
V
V
W
U
lectrical
Service
U
V
D*
V
Clearances to Electrical Service
P 6” - Non-vinyl sidewalls
12” – Vinyl sidewalls
Q 18” – Non-vinyl soffi t and overhang
42” – Vinyl soffi t and overhang
R 8 ft.
S
min
T
max
1 cap 3 ft 2 x S actual
2 caps 6 ft 1 x S actual
3 caps 9 ft 2/3 x S actual
4 caps 12 ft 1/2 x S actual
S
= # term caps x 3 T
min
= (2/# term caps) x S (actual)
max
U 6” min. – Clearance from sides of electrical service.
W 12” min. – Clearance above electrical service.
* As specifi ed in CGA B149 Installation Codes
Note: Local codes or regulations may require different clearances.
** Clearance required to vinyl soffi t material – 30 in. (76 cm) minimum.
Note: Location of the vent termination must not interfere with access
to the electrical service.
WARNING!
In the U.S.: Vent system termination is NOT permitted in screened
porches. You must follow side wall, overhang and ground clearances as stated in the instructions.
In Canada: Vent system termination is NOT permitted in screened
porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow all side wall, overhang and ground clearances as stated in the instructions.
Hearth & Home Technologies assumes no responsibility for the improper
performance of the appliance when the venting system does not meet these requirements.
Figure 4.4 Minimum Clearances for Terminations
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 13
5
Vent Information and Diagrams
5
A. Vent Table Key
The abbreviations listed in this vent table key are used in the vent diagrams.
Symbol Description
V
V
H
H
First section (closest to appliance) of vertical length
1
Second section of vertical length
2
First section (closest to appliance) of horizontal length
1
Second section of horizontal length
2
Vertical
12 in.
8-1/2 in.
8-1/2 in.
WARNING
Fire Risk Explosion Risk Asphyxiation Risk
Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance.
• Vent this appliance directly outside.
• Use separate vent system for this
appliance.
May impair safe operation of this appliance or other appliances connected to the fl ue.
B. Use of Elbows
CAUTION
ALL vent configuration specifications MUST be followed.
• This product is tested and listed to these specifi cations.
• Appliance performance will suffer if specifi cations are not followed.
Diagonal runs have both vertical and horizontal vent aspects when calculating the effects. Use the rise for the vertical as­pect and the run for the horizontal aspect (see Figure 5.1).
Two 45° elbows may be used in place of one 90° elbow. On 45° runs, 1 ft of diagonal is equal to 8-1/2 in. horizontal run and 8-1/2 in. vertical run. A length of straight pipe is allowed between two 45° elbows (see Figure 5.1).
Horizontal
Figure 5.1 Using Two 45° Elbows
C. Measuring Standards
Vertical and horizontal measurements listed in the vent dia­grams were made using the following standards.
• Pipe measurements are shown using the effective length of pipe (see Figure 5.2).
• Measurements are made from the appliance outer wrap, not from the standoffs.
• Horizontal terminations are measured to the outside mounting surface (flange of termination cap) (see Figure 4.1).
• Vertical terminations are measured to top of last pipe before termination cap.
• Horizontal pipe installed level with no rise.
Pipe Effective Length
DVP4 4 in. (102 mm) DVP6 6 in. (152 mm)
Effective
Length
DVP Pipe
(see chart)
DVP12 12 in. (305 mm) DVP24 24 in. (610 mm) DVP36 36 in. (914 mm) DVP48 48in.(1219mm) DVP6A 3to6in.(76to152mm)
DVP12A 3to12in.(76to305mm) DVP12MI 3 to 12 in. (76 to 305 mm) DVP24MI 3 to 24 in. (76 to 610 mm)
14 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
Figure 5.2 DVP Pipe Effective Length
D. Vent Diagrams
WARNING
Fire Risk Explosion Risk
Do NOT pack insulation or other combustibles between fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install fi restops as specifi ed. Failure to keep insulation or other material away from vent pipe may cause fi re.
The fi rst 90° elbow MUST be a starter elbow.
To replace the fi rst starter elbow with two 45° elbows, refer to Figure 5.4. All other 90° elbows can be replaced with two 45° elbows.
General Rules:
SUBTRACT 3 ft from the total H measurement for each 90° elbow installed horizontally. SUBTRACT 1-1/2 ft from the total H measurement for each 45° elbow installed horizontally.
A maximum of three 90° elbows (or six 45° elbows) may be used in any vent confi guration. Some elbows may be installed horizontally. See Figure 5.6.
Elbows may be placed back to back anywhere in the system except as shown in Figure 5.4.
When penetrating a combustible wall, a wall shield restop must be installed.
When penetrating a combustible ceiling, a ceiling restop must be installed.
Top Vent—Horizontal Termination—One Elbow
V1 min. V1 max. H1 max.
0* - 18 in./457 mm
6 in./152 mm - 6 ft/1.83 m
12 in./305 mm - 11 ft/3.35 m
18 in./457 mm - 18 ft/5.49 m
24 in./610 mm - 25 ft/7.62 m
- 25 ft/7.62 m 25 ft/7.62 m
* You may install the elbow directly on top of the
CD4236. The CD4842 requires the DVP6 vent section prior to the elbow.
H
1
V
1
Figure 5.3 Top Vent-Horizontal Termination-One Elbow
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 15
Top Vent—Horizontal Termination—Two 45° Elbows
Installation requirements to replace the fi rst 90° elbow with two 45° elbows:
Figure 5.4 Minimum Installation Requirements for Two 45° Elbows-Top Vent-Horizontal Termination
Top Vent—Horizontal Termination—Three Vertical Elbows
See Figure 5.6 for information about installing elbows horizontally.
4 ft min.
(1.22 m)
25 ft max.
(7.62 m)
H
V1 min. V1+V2 max. H1+H2 max.
1 ft
.30 m
2
V
2
24 ft
7.32 m
19 ft
5.79 m
Installed
Vertically
H
1
V
1
Figure 5.5 Three Vertically Installed 90° Elbows
16 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
Top Vent—Horizontal Termination—Two or Three Elbows
You may use a maximum of three 90° elbows (or six 45° elbows) in any vent confi guration, Some may be installed hori- zontally.
Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally. Subtract 1-1/2 ft (457 mm) from the total horizontal measurement for each 45° elbow installed horizontally.
V1 min. V1 max. H1+H2 max. H1+H2 +H3 max.
6 in./152 mm x 6 ft/1.83 m x
12 in./305 mm x 11 ft/3.35 m 11 ft/3.35 m
18 in./457 mm x 18 ft/5.49 m 18 ft/5.49 m
24 in./610 mm x 25 ft/7.62 m 25 ft/7.62 m
x 25 ft/7.62 m 25 ft/7.62 m 25 ft/7.62 m
Horizontally
H
2
Figure 5.6 Two or Three Elbows, some Horizontal
H
2
H
3
Installed
H
1
Installed
Vertically
V
1
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 17
Top Vent—Vertical Termination—No Elbows
Note: If installing a vertical vent/termination
run off the top of the appliance, the vertical termination baffl e supplied with the appliance may be used. See Section E.
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Figure 5.7 Vertical Termination - No Elbows
Top Vent—Vertical Termination—Two Elbows
Note: If installing a vertical vent/
termination run off the top of the appliance, the vertical termination baffl e supplied with the appliance may be used. See Section E.
12 ft (3.66 m) min. 60 ft (18.29 m) max.
Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m)
Figure 5.8 Vertical Termination - Two Elbows
18 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
Top Vent—Vertical Termination—Three Elbows
Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally. Subtract 1-1/2 ft (457 mm) from the total horizontal measurement for each 45° elbow installed horizontally.
Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m)
12 ft (3.66 m) min. 60 ft (18.29 m) max.
Figure 5.9 Vertical Termination - Three Elbows (some horizontal)
Rear Vent—Horizontal Termination—No Elbows
Note: If installing a vertical vent/termination
run off the top of the appliance, the vertical termination baffl e supplied with the appliance may be used. See Section E.
Figure 5.10 Horizontal Termination - No Elbows
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 19
18 in. (457 mm) max.
Rear Vent—Horizontal Termination—One 45° Elbow
18 in. (457 mm) max.
Figure 5.11 Horizontal Termination - One 45° Elbow
Rear Vent—Horizontal Termination—Two Elbows
H
2
V
1
H
1
H1 Max V1 Min H1 + H2 Max
2 ft/.61 m 1 ft/.30 m 3 ft/.91 m
4 ft/1.22 m 2 ft/.61 m 6 ft/1.83 m
6 ft/1.83 m 3 ft/.91 m 9 ft/2.74 m
8 ft/2.44 m 4 ft/1.22 m 12 ft/3.66 m
8 ft/2.44 m 5 ft/1.52 m 15 ft/4.57 m
8ft/2.44 m 6 ft/1.83 m 18 ft/5.49 m
Figure 5.12 Horizontal Termination - Two Elbows
20 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
Rear Vent—Horizontal Termination—Three Elbows
Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally. Subtract 1-1/2 ft (457 mm) from the total horizontal measurement for each 45° elbow installed horizontally.
Installed
Horizontally
H
3
H
Max V1 Min H1 + H2 + H3 Max
1
2 ft/.61 m 1 ft/.30 m 3 ft/.91 m
4 ft/1.22 m 2 ft/.61 m 6 ft/1.83 m
6 ft/1.83 m 3 ft/.91 m 9 ft/2.74 m
8 ft/2.44 m 4 ft/1.22 m 12 ft/3.66 m
8 ft/2.44 m 5 ft/1.52 m 15 ft/4.57 m
8 ft/2.44 m 6 ft/1.83 m 18 ft/5.49 m
H
V
2
1
H
1
Figure 5.13 Horizontal Termination - Three Elbows
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 21
Rear Vent—Vertical Termination—One Elbow
Note: If installing a vertical
vent/termination run off the rear of the appliance, the vertical termination baffle supplied with the appliance may be used. See Section E.
12 ft (3.66 m) min. 60 ft (18.29 m) max.
Figure 5.14 Vertical Termination - One Elbow
0 min.
6 ft (1.83 m) max.
Rear Vent—Vertical Termination—Two Elbows
Note: Subtract 3 ft (914 mm) from the total horizontal measurement for each 90° elbow installed horizontally. Subtract 1-1/2 (457 mm) ft from the total horizontal measurement for each 45° elbow installed horizontally.
12 ft (3.66 m) min. 60 ft (18.29 m) max.
Maximum horizontal run is 100% of vertical, but cannot exceed 26 ft (7.92 m)
0 min.
6 ft (1.83 m) max.
Note: If installing a vertical vent/termination run off the rear of the appliance, the vertical termination baffl e supplied with the appliance may be used. See Section E.
Figure 5.15 Vertical Termination - Two Elbows
22 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
Rear Vent—Vertical Termination—Three Vertical Elbows
12 ft (3.66 m) min. 60 ft (18.29 m) max.
Maximum horizontal run is 100% of vertical, but can­not exceed 26 ft (7.92 m).
0 min.
6 ft (1.83 m) max.
Figure 5.16 Vertical Termination - Three Vertical Elbows
Note: If installing a vertical vent/termination
run off the rear of the appliance, the vertical termination baffl e supplied with the appliance may be used. See Section E.
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 23
E. Installing Vertical Termination Baffl e
Note: For vertically terminated installations only.
Note: If installing a vertical vent/termination run off the
top or rear of the appliance, the vertical termination baffl e supplied with the appliance may be used.
1. Remove the glass (refer to Section 12.H.) to access the
rebox and 5 in. inner fl ue.
2. Fold the baffl e (Figure 5.17) to an approximate 90° angle
(see Figure 5.18).
3. Squeeze the open end of the bent baffl e with one hand. Insert the baffl e bent side up into the inner fl ue so that the bottom of the baffl e is above the bead on the inside of the collar. See Figure 5.19.
Figure 5.19 Placing the Baffl e
4. Release pressure on the baf e so that it is wedged against
the sides of the fl ue collar. See Figure 5.20.
Figure 5.17 Flat Baffl e
Figure 5.18 Baffl e Bent to 90° Angle
Figure 5.20 Baffl e in Place
5. Replace the glass (refer to Section 12.H.).
6. Start the appliance.
24 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
D
Top Vent
E
Rear Vent
inches
42-1/4 27-1/4
mm
1073 692
inches 48-1/4 27-1/4
mm
1226 692
Model
CD4236R
CD4842R
6
Vent Clearances and Framing
6
A. Pipe Clearances to Combustibles
Fire Risk Explosion Risk
Maintain vent clearance to combustibles as specifi ed.
• Do not pack air space with insulation or
Failure to keep insulation or other materials away from vent pipe may cause fi re.
Drywall
1 in. (25 mm)
2 x 4 or 2 x 6 header
WARNING
other materials.
3 in.
(76 mm)
Air space clearances to bottom and sides of horizontal pipe must be at least 1 in. (25 mm)
No combustible framing to be located within shaded area.
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required.
Heat Shield
Wall
Shield
Firestop
WALL
Figure 6.2 Minimum Horizontal Venting Clearances to Combus­tible Materials
3 in. (76 mm) top clearance
Heat Shield
1 in. (25 mm) clearance bottom & sides
1/2 in. (13 mm) minimum to
WALL
perpendicular wall.
Figure 6.1 Minimum Top Vented DV Pipe Clearances
B. Wall Penetration Framing
• Wherever a combustible wall is penetrated, the hole must be framed with a wall shield fi restop. This shield maintains minimum clearances and restricts cold air infi ltration.
• If the wall being penetrated is of noncombustible materials (material which will not ignite or burn, or has a UL fi re rating of zero), a 9 in. (229 mm) diameter hole is acceptable.
• Whenever a wall is penetrated the wall shield fi restop is only required on one side and no heat shield is necessary.
• If your local inspector requires the wall shield fi restop on both sides of the wall, then both wall shield fi restops must have a heat shield attached to them.
10 in.
12 in.
The center of the framing hole is 1 in. (25mm) above the center of the horizontal vent pipe.
Framing should be constructed of 2 X 4 lumber or heavier.
* Measured to center of pipe.
Figure 6.3 Exterior Wall Hole
6ENTFRAMINGHOLE $/./40!#+7)4( ).35,!4)/./2/4(%2
-!4%2)!,
D*
E*
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07 25
C. Install the Ceiling Firestop
• Frame an opening 10 in. by 10 in. whenever the vent system penetrates a ceiling/fl oor (see Figure 6.4).
• Frame the area with the same sized lumber as used in ceiling/fl oor joist.
• When installing a top vent vertical termination appliance the hole should be directly above the appliance, unless the fl ue is offset.
• The ceiling fi restop may be installed above or below the ceiling. Refer to Figure 6.5.
• Secure with three fasteners on each side.
• Do not pack insulation around the vent. Insulation must be kept away from the pipe.
Attic Above
10 in. (254 mm)
10 in.
(254 mm)
Hole should measure
10 in. x 10 in.
(254 mm x 254 mm)
inside to inside
Figure 6.4 Installing Ceiling Firestop
Install attic insula­tion shields before or after installation of vent system.
3 fasteners
per side
Ceiling firestop
installed below ceiling.
Figure 6.5 Installing Ceiling Firestop & Attic Insulation Shield
Ceiling firestop
installed above ceiling.
26 Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
Loading...