Heath Zenith UT-5681-BZ User Manual

Item Model
135931 UT-5681-BZ
Compact Fluorescent Dusk-to-
Dawn 42 Watt Security Light
Questions or problems? Before returning to your retailer, call our technical service department at 1-800-858-8501 (English speaking only), 7:30 am to 4:30 pm, CST, Monday – Friday.
PACKAGE CONTENTS
• Security light • Bulb
• 1/2" NPT nut • Lag bolts (x3)
• Mounting template
INSTALLATION INSTRUCTIONS
Estimated Installation Time: 1 hour Items needed for installation (not included):
• Phillips and fl athead screwdrivers
• Pliers • Wire strippers/cutters
• Safety glasses • Silicone caulk
• Ladder • Black tape
• Conduit fi tting Additional item needed for junction box installation (not included):
• Junction box cover with threaded hole (1/2" NPT)
READ ALL INSTRUCTIONS CAREFULLY BEFORE
BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National
Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualifi ed electrician if there is any question as to the suit­ability of the system.
Lamp in Fixture Contains Mercury. Dispose According to Local, State, or Federal Laws.
Installation of Diffuser
Note: It is recommended to install the diffuser before mounting fi xture to wall or junction box.
1. Place fi xture upside down on a solid surface.
2. Remove diffuser locking screw from fi xture (see Figure 1).
3. Align the notches in the diffuser with the tabs on the fi xture and place the diffuser on the fi xture (see Figure 1).
Rotate the diffuser clockwise until the diffuser stops (see Figure 1).
4.
5. Install locking screw removed in step 2 (see Figure 1).
Diffuser
Diffuser Locking
Screw
Diffuser Notch
Fixture Tab
Fixture
Figure 1
© 2008 HeathCo LLC 598-1350-01
WARNING: Turn power off at the circuit breaker
or fuse.
This fi xture can be directly wall mounted or wall mounted using a weatherproof junction box. Use the instructions below that apply to your application.
Installation Without A Junction Box
1. Select a location on a fl at wall with structurally sound wood and from 5 to 25 feet (1.5 to 7.6 m) from the ground. The wood should be at least one inch (25 mm) thick to safely secure the fi xture.
2. Using the mounting template as a guide, mark the 3 mounting holes. We suggest drilling 3/16" (4.8 mm) pilot holes for the lag screws.
3. Install the two bottom lag screws fi rst. Screw in the lag screws so that there is about 3/8" (9.5 mm) of space under the head.
4. Apply silicone caulk around threaded hole on rear of fi xture.
5. Place the fi xture on these two screws and install the top lag screw. Tighten the top lag screw fi rst, then tighten the remaining lag screws.
6. Remove the two screws attaching the fi xture cover plate to the fi xture (see Figure 2).
7. Route the service wires from the conduit through the fi xture cover plate (see Figure 2).
8. Secure your outdoor cable or fl exible conduit to the cover plate with a fi tting (not supplied) in accordance with the National Electrical Code (Canadian Electrical Code in Canada).
Installation Using A Junction Box
1. Thread 1/2" NPT coupler (supplied) into the threaded hole on the rear of the fi xture.
2. Attach junction box cover plate with 1/2" NPT threads (not supplied) to coupler.
3. Verify the mounting holes on the cover plate are correctly aligned with the mounting holes on the junction box and install the 1/2" NPT nut behind the cover plate. Securely tighten nut against back of cover plate.
4. Caulk between coupler and cover plate.
5. Remove the two screws attaching the fi xture cover plate to the fi xture.
6. Route service wires through coupler and into the fi xture.
7. Securely attach the cover plate to the junction box.
Complete The Installation
1. Connect the fi xture wires to the service wires as shown in Figure 2 (black to black and white to white).
2. This fi xture must be connected to ground. Secure the service ground wire under the head of the green ground screw (see Figure 2).
3. Install the cover plate. Secure with the two screws provided (see Figure 2).
4. Plug in the 42 watt compact fl uorescent lamp provided (NEMA designation CFTR42W/GX24Q with GX24Q-4 base).
ATTENTION: When removing, grasp bulb by the base. Do not
grasp glass bulb to remove.
CAUTION: Do not use any other wattage lamps
in this fi xture.
To test operation during daylight, cover the photocontrol (round object on front of fi xture) with black electrical tape. Turn on the power. The light should come on immediately and will take a few minutes to reach full brightness. Uncover the photocontrol and your unit will operate automatically—on at dusk, off at dawn.
Lag Screw
Caulk
Ground
Screw
Cover Plate
Bulb
Figure 2
2
598-1350-01
Luz de seguridad compacta
fl uorescente de 42 vatios para
Articulos Modelo
135931 UT-5681-BZ
¿Preguntas o problemas? Antes de devolver el producto al minorista, llame a nuestro departamento de servicio técnico al 1-800-858-8501 (sólo se habla inglés), de 7:30 am a 4:30 pm, Hora Estándar del Centro, de Lunes a Viernes.
CONTENIDOS DEL PAQUETE
• Luz de seguridad • Bombilla
• Conectores de alambre • Acoplador NPT de 1/2 Pulg.
• Tuerca NPT de 1/2 Pulg. • Tirafondos (x3)
• Plantilla de montaje
INDICACIONES PARA SU INSTALACIÓN
Tiempo estimado de instalación: 1 hora Artículos que se necesitan para la instalación (no incluidos):
• Tornillos Phillips y de cabeza plana
• Alicates
• Desforrador/cortador de alambre
• Lentes de seguridad • Calafateo de silicona
• Escalera • Cinta aislante negra
• Accesorio del conducto Se necesita un artículo adicional para la instalación de la caja de
empalme (no incluidos):
• Tapa de la caja de empalmen con orifi cio roscado (1/2" NPT)
LEA TODAS LAS INDICACIONES CON CUIDADO
ANTES DE COMENZAR LA INSTALACIÓN.
NOTA: Todo el cableado debe estar hecho de acuerdo al Código
Eléctrico Nacional (Código Eléctrico Canadiense en Cana­dá) por medio de conductos o de otro medio aceptable. Co­muníquese con un electricista profesional si tiene preguntas relacionadas con la aptitud del sistema.
usarla desde el anochecer
hasta el amanecer
La lámpara en el dispositivo contiene mercurio. Deseche de acuerdo con las leyes locales, estatales o federales.
Instalación del difusor
Nota: Se recomienda instalar el difusor antes de instalar el aparato a la pared o a la caja de empalme.
1. Ponga el aparato boca arriba sobre una superfi cie sólida.
2. Quite del aparato el tornillo de fi jación del difusor (vea la Figura 1).
3. Alinee las ranuras del difusor con las aletas del aparato y coloque el difusor sobre el aparato (vea la Figura 1).
4. Gire el difusor en sentido horario hasta que el difusor se pare (vea la Figura 1).
5. Ponga el tornillo de fi jación que se quitó en el paso 2 (vea la Figura 1).
Difusor
Tornillo de
fi jación del
difusor
598-1350-01
Ranura del
aparato
Aleta del
aparato
Aparato
Figura 1
3© 2008 HeathCo LLC 598-1350-01 S