Heath Zenith UT-5666-AL User Manual

Item Model
247591 UT-5666-AL
100 Watt H.P.S.
Dusk-to-Dawn Security Light
Questions or problems? Before returning to your retailer, call our technical service department at 1-800-858-8501 (English speaking only), 7:30 am to 4:30 pm, CST, Monday – Friday.
INSTALLATION INSTRUCTIONS
WITH TWO PIECE ARM
Estimated Installation Time: 60 minutes Items needed for installation (not included):
• Phillips and flathead screwdrivers
• 13 mm, 10 mm, and 8 mm sockets
• 3/16" Drill bit • Drill
• Pliers • Wire strippers/cutters
• Safety glasses • Silicone caulk
• Ladder • Small box or rag
READ ALL INSTRUCTIONS CAREFULLY BEFORE
BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National
Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suit­ability of the system.
Lamp in Fixture Contains Mercury. Dispose According to Local, State, or Federal Laws.
10. Connect the fixture wires to the service wires using the wire nuts provided (black to black and white to white). Push the connec­tions as far as possible into the straight arm.
11.
This fixture must be grounded. Connect the service ground under the head of the green ground screw and secure to the mounting strap.
12. Install the lens/reflector assembly with two screws and washers provided.
13. Screw in the 100 watt H.P. Sodium type S54 bulb provided.
14. Loosen the screw in the center of the photocontrol socket two turns. Twist the socket so that the arrow points north. Note: There is a stop to prevent the socket from turning all the way around. If you have trouble turning the socket, try turning it the other direc­tion. Retighten the screw in the center of the socket.
15. Align the photocontrol (it will only plug-in one way). Plug it in and twist clockwise until it stops.
To test operation during the daytime, cover the photocontrol with a small box or rag. Turn the power on. Light should turn on and reach full brightness within ten minutes. Remove the box or rag to expose the photocontrol to daylight. Light should turn off within two minutes. With the photocontrol exposed, the light will operate automatically – on at dusk and off at dawn.
Photocontrol
WARNING: Turn power off at the circuit breaker or
fuse.
1. Select a location on a flat wall with structurally sound wood and from 10 to 25 feet (3 to 7.6 m) from the ground. The wood should be at least one inch thick to safely secure the fixture.
2. Slide the curved section of the mounting arm into the mounting bracket. Tighten the bolts on the mounting bracket evenly.
3. Using the mounting arm and bracket as a guide mark four mount­ing holes. We suggest drilling 3/16" (4.8 mm) pilot holes for the lag screws.
4. Mount the arm and bracket using four lag screws and washers provided.
5. Place a ring of silicone caulk around mounting arm (see illustra­tion). Slide the straight section of the mounting arm on to the curved section aligning the predrilled holes.
6. Secure the two sections with two bolts, nuts and four washers provided. Place silicone caulk on top of the bolts and washers to prevent water from entering.
7. Thread your outdoor cable or flexible conduit through the mount­ing arm.
8. Loosely connect the mounting strap to the fixture using two bolts provided.
9. Slide the fixture on to the mounting arm until the fixture comes to a stop. Secure the fixture to the mounting arm by tightening the two mounting strap bolts.
© 2008 HeathCo LLC 598-1288-04
Mounting Strap
Lens/Reflector
Assembly
Package Contents and Fixture Assembly
Mounting
Arm
Silicone
Caulk
Ground
Screw
Lag Screw (4)
Bulb
Mounting
Bracket
Questions or problems? Before returning to your retailer, call our technical service department at 1-800-858-8501 (English speaking only), 7:30 am to 4:30 pm, CST, Monday – Friday.
INSTALLATION INSTRUCTIONS
WITHOUT TWO PIECE ARM
Estimated Installation Time: 45 minutes Items needed for installation (not included):
• Phillips and flathead screwdrivers
• 13 mm, 10 mm, and 8 mm sockets
• 3/16" Drill bit • Drill
• Pliers • Wire strippers/cutters
• Safety glasses • Silicone caulk
• Ladder • Small box or rag
READ ALL INSTRUCTIONS CAREFULLY BEFORE
BEGINNING INSTALLATION.
NOTE: All wiring must be run in accordance with the National
Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suit­ability of the system.
13. Loosen the screw in the center of the photocontrol socket two turns. Twist the socket so that the arrow points north. Note: There is a stop to prevent the socket from turning all the way around. If you have trouble turning the socket, try turning it the other direction. Retighten the screw in the center of the socket.
14. Align the photocontrol (it will only plug-in one way). Plug it in and twist clockwise until it stops.
To test operation during the daytime, cover the photocontrol with a small box or rag. Turn the power on. Light should turn on and reach full brightness within ten minutes. Remove the box or rag to expose the photocontrol to daylight. Light should turn off within two minutes. With the photocontrol exposed, the light will operate automatically – on at dusk and off at dawn.
Photocontrol
Lag Screw (3)
Lamp in Fixture Contains Mercury. Dispose According to Local, State, or Federal Laws.
WARNING: Turn power off at the circuit breaker or
fuse.
1. Select a location on a flat wall with structurally sound wood and from 10 to 25 feet (3 to 7.6 m) from the ground. The wood should be at least one inch (25 mm) thick to safely secure the fixture.
2. The fixture can be mounted with three lag screws and washers which are provided.
3. Using the mounting template as a guide, mark three mounting holes. We suggest drilling 3/16" (4.8 mm) pilot holes for the lag screws.
4. Install the bottom two lag screws first. Screw in the lag screws so that there is about 3/8" (9.5 mm) of space under the head.
5. Place the fixture on these two lag screws and install the top lag screw. Tighten the top lag screw first, then tighten the remaining lag screws
6. Secure your outdoor cable or flexible conduit to the cover plate with a fitting in accordance with the National Electrical Code (Canadian Electrical Code in Canada).
7. Thread the black and white fixture wires through the hole in the cover plate as shown.
8. Connect the fixture wires to the service wires using the wire nuts provided (black to black and white to white).
9. This fixture must be grounded. Connect the service ground under the head of the green ground screw and secure to the fixture.
10. Install the cover plate. Secure with the two screws, two nuts and four washers provided.
11. Install the lens/reflector assembly with two screws and washers provided.
12. Screw in the 100 watt H.P. Sodium type S54 bulb provided.
Mounting
Plate
Ground
Screw
Cover
Plate
Lens/Reflector
Assembly
Bulb
Flat Washer (9)
Package Contents and Fixture Assembly
2
598-1288-04
Lamp
Socket
Photocell
Socket
Ballast
Ignitor
Red
Red
Red
Black
Black
Blue Blue
White
White
White
Black
White
Black
120V AC
Input
Ballast Assembly Replacement Instructions
Ballast assembly can be replaced without the cutting of any wires. Use of a qualified electrician is recom­mended.
CAUTION: Make sure the power is off before starting the installation.
1. Remove bulb.
2. Loosen two screws holding plastic/aluminum reflector and remove reflector.
3. Remove two screws connecting ballast assembly to aluminum housing.
4. Remove tape from wire bundle. Be careful not to damage wires.
5. Label wires according to wiring diagram.
6. Remove wire nuts from wires. Retain wire nuts to connect replacement ballast assembly.
7. Remove screw holding ignitor to ballast assembly.
8. Remove two screws holding lamp socket to ballast assembly.
9. Dispose of used ballast assembly.
10. Connect the replacement ballast assembly following steps 1 through 8 in reverse order.
Aluminum
Housing
Ignitor Retention Screw
Ballast Retention Screw
Ballast Assembly
Lock Washer
Lamp Socket
Lamp Socket
Retention Screw
3
Ignitor
598-1288-04
THREE YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.
For a period of three years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other ex­pendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.
This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABIL­ITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclu­sion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
4
598-1288-04
Loading...
+ 8 hidden pages