Heath Zenith UT-5105-WH, UT-5105-BZ User Manual

Motion Sensor Light Control
Requirements
• The light control requires 120-volts AC.
• If you want to use the Manual Mode, the control must be wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
Items Models
247580 UT-5105-BZ 182155 UT-5105-WH
Meets the ENERGY STAR® guidelines when DualBrite® function is off and ON-TIME is 1 or 5 minutes and when used with 120 W Max bulbs.
Questions or problems? Before returning to your re­tailer, refer to the troubleshooting guide in this manual or call our technical service department at 1-800-858­8501 (English speaking only), 7:30 am to 4:30 pm, CST,
Monday – Friday.
Features
DualZone™ Technology.
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
DualBrite® Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
OPERATION
Mode: On-Time Works: Day Night
Test Auto Manual Accent
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put ON-TIME switch on the sensor bottom to TEST and the Dual-
Brite® switch OFF.
Put the ON-TIME switch in the 1, 5, or 20 minute position.
5 Seconds x x
1, 5, or 20 Min x
To Dawn* x
3, 6 Hr, to Dawn x
* resets to Auto Mode at dawn.
TEST
ON-TIME
TEST 1 5 20
AUTO
DualBrite
Off 3 6 Dusk to Dawn
ON-TIME
TEST 1 5 20
®
Package Contents
Manual mode only works at night
Bulb Holders
Cover
Plate
Light Control
Mounting Bolt
Plastic Hanger
© 2007 HeathCo LLC 598-1292-03
Rubber Plug
2 Shells
Sensor
Gasket
6 Screws
(3 sizes included)
Connectors
Mounting Strap
because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.
MANUAL MODE
1 Second OFF
then...
... back on.
Mode Switching Summary
MANUAL MODE
AUTO
TEST
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
For easy installation, select an existing light with a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground. 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
NOTE:
If fixture is mounted higher than
DualBrite® Timer
Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.
INSTALLATION
Estimated Installation Time: 30 minutes Items needed for installation (not included):
• Phillips and flathead screwdrivers
• Pliers • Wire strippers/cutters
• Safety glasses • Light bulbs
• Silicone caulk • Ladder
• Black tape
WARNING: Turn power off at circuit breaker
or fuse.
Wall Mount
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
Swing the sensor head towards the clamp screw
joint.
Clamp Screw
Then rotate the sensor head clockwise 180° so
the controls face down.
Controls
Eave Mount
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
2
598-1292-03
WIRING
❒ Remove the existing light fixture. Install the mounting strap as shown using two screws
that fit your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
❒ Route the light control’s wires through the large
gasket holes.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mount the Light Control
Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
Align the three slots in the decorative shell with the
bulb holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell.
Push the rubber plug firmly into place.
Shell Slot
Mounting
Strap
Junction box ground wire to green ground screw on fixture.
White to White
Black to Black
Gasket
Rubber
Plug
Mounting
Bolt
If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone weather sealant.
To avoid water damage and electrical shock, keep bulb holders 30° below horizontal.
Keep bulbs at least 1" (25 mm) from the
Lock Nut
❒ Adjust the bulb holders by loosening the lock nuts
but do not rotate the bulb holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.
sensor. Do not allow the bulbs to block the lens.Lens
598-1292-03
3
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF
3
6
DUSK TO
DAWN HOUR
B
O
O
S
T
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on, wait 1 1/2 minutes.
Note: Meets the ENERGY STAR® guidelines when
DualBrite® function is off and ON-TIME is 1 or 5 minutes
and when used with 120 W Max bulbs.
Turn the RANGE control to the medium position
(halfway between MIN and MAX), DualBrite® to OFF, and the ON-TIME control to the TEST position.
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance. The detector is less sensitive to motion directly towards it.
Motion
D
ualZone
Motion
D
ualZone
Sensor
Least Sensitive Most Sensitive
Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor.
Walk through the coverage
area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected). Move the sensor head up, down, or sideways to change the cover­age area. Keep the sensor at
Down for Short least 1" (25 mm) away from the bulbs.
Adjust the RANGE as needed.
RANGE set too high may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Higher for Long
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
Set the DualBrite® switch to the amount of time
after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).
Clamp Screw
Ball Joint
Aim Sensor
Coverage
Aim Sensor
Coverage
15 ft.
(4.6 m)
ualZone
D
70 ft. 100 ft. (21 m) (30.5 m)
D
ualZone
Boosted
Maximum Maximum Range Coverage Angle
240°
WARNING: Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
NOTE: DualZone™ is a new zone of detection which
was added as an option to select Heath®/Zenith motion sensing products. This feature adds a zone of detec­tion under the motion sensor. DualZone™ requires no additional adjustment and operates in conjuction with the forward-looking sensor.
4
598-1292-03
SPECIFICATIONS
Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost. [varies with surrounding
temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
Maximum each bulb holder.] Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
DualBrite® Timer . . . . 3, 6 hours, Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue prod­ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM
Lights will not come on.
Lig hts com e on in daylight.
Lights come on for no apparent rea­son.
Lights turn off too lat e in Dus k-to­Dawn setting
POSSIBLE CAUSE
1. Light switch is turned off.
2. F l o o d ligh t i s l o o s e or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect check after dark).
5. Incorrect circuit wiring, if this is a new installation.
6. Re-aim the sensor to cover de sired area.
1. Light control may be installed in a relatively dark location.
2. Light control is in T e s t .
(Set control switch t o an ON-TIME position).
1. Light control may be sensing small animals or automobile traffic (Re-aim sensor).
2. R a n g e is se t too high. (Reduce Range).
3. D
ualBrite
1. Sensor is in a relatively dark location. (Relocate sensor, or
use 3 hr or 6 hr setting.)
®
Timer is on.
(Re-
SYMPTOM
Lights stay on continuously.
-
Lights flash on and off.
Lig hts flash once, then stay off in Manual Mode.
POSSIBLE CAUSE
1. A flood bulb is positioned too close to the sensor or pointed at nearby objects that cause heat to trigger the sensor.
(Reposition the bulb away from the sensor or nearby objects).
2. Light control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface. (Reposition sensor. Reduce Range).
3. Light control is in Manual Mode.
(Switch to Auto.)
1. Heat or light from the bulbs may be turning the light control on and off.
(Reposition the bulbs away from the sensor).
2. Heat being reflected from other objects may be affecting the sensor. (Reposi- tion sensor).
3. Light control is in the Test mode and warming up. (Flashing is normal under
these conditions. Turn Boost off.)
4. Light may be leaking through the flood lamp reflectors. (Replace the bulbs
with new high quality PAR 38 bulbs or make sure the metal bulb protectors are installed).
1. Sensor is detecting its own lights.
(Reposition bulbs to keep area below the sensor relatively dark.)
-
598-1292-03
5
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to: HeathCo LLC P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur­chase, and Place of Purchase.
No Service Parts Available for this Product
FIVE YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of five years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modifica­tion of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROF­ITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
6
598-1292-03