• If you want to use the Manual Mode, the control must
be wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
ItemsModels
247580UT-5105-BZ
182155UT-5105-WH
Meets the ENERGY STAR® guidelines
when DualBrite® function is off and
ON-TIME is 1 or 5 minutes and when
used with 120 W Max bulbs.
Questions or problems? Before returning to your retailer, refer to the troubleshooting guide in this manual
or call our technical service department at 1-800-8588501 (English speaking only), 7:30 am to 4:30 pm, CST,
Monday – Friday.
Features
• DualZone™ Technology.
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• DualBrite® Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
OPERATION
Mode:On-TimeWorks:Day Night
Test
Auto
Manual
Accent
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put ON-TIME switch
on the sensor bottom
to TEST and the Dual-
Brite® switch OFF.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
MANUAL MODE
1 Second OFF
then...
... back on.
Mode Switching Summary
MANUAL MODE
AUTO
TEST
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
For easy installation, select an existing light with a wall
switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m)
above the ground.
8 ft. (2.4 m), aiming the sensor down will reduce coverage
distance.
NOTE:
If fixture is mounted higher than
DualBrite® Timer
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒ Then rotate the sensor head clockwise 180° so
the controls face down.
Controls
Eave Mount
Controls
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
2
598-1292-03
WIRING
❒ Remove the existing light fixture.
❒ Install the mounting strap as shown using two screws
that fit your junction box.
❒ The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
❒ Route the light control’s wires through the large
gasket holes.
❒ Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Mount the Light Control
❒ Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
❒ Align the three slots in the decorative shell with the
bulb holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
❒ Push the rubber plug firmly into place.
Shell Slot
Mounting
Strap
Junction box ground wire to
green ground screw on fixture.
White to
White
Black to
Black
Gasket
Rubber
Plug
Mounting
Bolt
❒ If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone
weather sealant.
To avoid water damage and electrical shock,
keep bulb holders 30° below horizontal.
Keep bulbs at least
1" (25 mm) from the
Lock Nut
❒ Adjust the bulb holders by loosening the lock nuts
but do not rotate the bulb holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
sensor. Do not allow
the bulbs to block
the lens.Lens
598-1292-03
3
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST 1 5 20
MINUTES
OFF
3
6
DUSK TO
DAWN HOUR
B
O
O
S
T
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
Note: Meets the ENERGY STAR® guidelines when
DualBrite® function is off and ON-TIME is 1 or 5 minutes
and when used with 120 W Max bulbs.
❒ Turn the RANGE control to the medium position
(halfway between MIN and MAX), DualBrite® to OFF,
and the ON-TIME control to the TEST position.
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
may trigger the shut-off feature. Do not point other
lights at the sensor.
NOTE:
If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
D
ualZone™
Motion
D
ualZone™
Sensor
Least Sensitive Most Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected). Move
the sensor head up, down, or
sideways to change the coverage area. Keep the sensor at
Down for Short
least 1" (25 mm) away from
the bulbs.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Higher for Long
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
❒ Set the DualBrite® switch to the amount of time
after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).
Clamp
Screw
Ball
Joint
Aim Sensor
Coverage
Aim Sensor
Coverage
15 ft.
(4.6 m)
ualZone™
D
70 ft. 100 ft.
(21 m) (30.5 m)
D
ualZone™
Boosted
Maximum
Maximum Range Coverage Angle
240°
WARNING: Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
NOTE: DualZone™ is a new zone of detection which
was added as an option to select Heath®/Zenith motion
sensing products. This feature adds a zone of detection under the motion sensor. DualZone™ requires
no additional adjustment and operates in conjuction
with the forward-looking sensor.
4
598-1292-03
SPECIFICATIONS
Horizontal Range . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80°
Vertical
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
Maximum each bulb holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 20 minutes
DualBrite® Timer . . . . 3, 6 hours, Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM
Lights will not come
on.
Lig hts com e on
in daylight.
Lights come on for
no apparent reason.
Lights turn off too
lat e in Dus k-toDawn setting
POSSIBLE CAUSE
1. Light switch is turned off.
2. F l o o d ligh t i s l o o s e or
burned out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turn-off is in effect
check after dark).
5. Incorrect circuit wiring, if this is
a new installation.
6. Re-aim the sensor to cover de
sired area.
1. Light control may be installed in
a relatively dark location.
2. Light control is in T e s t .
(Set control switch t o an
ON-TIME position).
1. Light control may be sensing
small animals or automobile
traffic (Re-aim sensor).
2. R a n g e is se t too high.
(Reduce Range).
3. D
ualBrite
1. Sensor is in a relatively dark
location. (Relocate sensor, or
use 3 hr or 6 hr setting.)
®
Timer is on.
(Re-
SYMPTOM
Lights stay on
continuously.
-
Lights flash on
and off.
Lig hts flash
once, then stay
off in Manual
Mode.
POSSIBLE CAUSE
1. A flood bulb is positioned too close to
the sensor or pointed at nearby objects
that cause heat to trigger the sensor.
(Reposition the bulb away from the
sensor or nearby objects).
2. Light control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface.
(Reposition sensor. Reduce Range).
3. Light control is in Manual Mode.
(Switch to Auto.)
1. Heat or light from the bulbs may be
turning the light control on and off.
(Reposition the bulbs away from the
sensor).
2. Heat being reflected from other objects
may be affecting the sensor. (Reposi-tion sensor).
3. Light control is in the Test mode and
warming up. (Flashing is normal under
these conditions. Turn Boost off.)
4. Light may be leaking through the flood
lamp reflectors. (Replace the bulbs
with new high quality PAR 38 bulbs or
make sure the metal bulb protectors
are installed).
1. Sensor is detecting its own lights.
(Reposition bulbs to keep area below
the sensor relatively dark.)
-
598-1292-03
5
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com.
If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST
(M-F). You may also write* to:
HeathCo LLC
P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
FIVE YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from
state to state or province to province.
For a period of five years from the date of purchase, any malfunction caused by factory defective parts or
workmanship will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs,
batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does
not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or
return shipping charges.
This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and
components that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT
THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF
ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL
BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please
keep your dated sales receipt, it is required for all warranty requests.