As an ENERGY STAR® Partner, Heath®/Zenith has determined that this product meets
the ENERGY STAR® guidelines for energy
efficiency. This product is ENERGY STAR
compliant when used with 120 Watt bulbs.
Model SL-9525
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Lamp Holders
Cover
Plate
OPERATION
Mode:On-Time:Works:DayNight
Test5 Secxx
Auto1, 5, 10 min.x
ManualUntil Dawn*x
* resets to Auto Mode at dawn.
1
Note: When first turned on wait about 1
the circuitry to calibrate.
®
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Manual mode only works at night
because daylight returns the sensor to AUTO.
TEST
AUTO
MANUAL MODE
/2 minutes for
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
2 Shells
Sensor
Light Control
Light Shield
4 Screws
(2 sizes included)
2 Flood Lamps
2 Wire
Connectors
Gasket
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
Flip the light switch off for one second then back on to toggle between
AUTO and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
1 Second OFF
then...
... back on.
Mode Switching Summary
TEST
Move ON-TIME Switch to
1, 5, or 10 minutes
AUTO
Flip light switch off
for one second then
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
For easy installation, select an existing light with a wall
switch for replacement.
❒Drill out the holes if
needed to mount the
backplate to the junction box.
❒Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
White to
Gasket
White
2345678901234567
Wall MountEave Mount
For under eave installation, the sensor head must be
rotated as shown in the next two steps for proper opera-tion and to avoid the risk of electrical shock. Also for
proper under eave operation, remove the protective
backing from the Light Shield and stick on as shown below.
For eave mount only:
❒Swing the sensor head towards the clamp screw
joint.
Clamp Screw
❒Then rotate the sensor head clockwise 180° so
the controls face down.
Controls
Light Shield
Opening
Controls
Black to
Black
Junction box ground wire to
green ground screw on fixture.
MOUNTTHE LIGHT CONTROL.
❒Align the Light Control cover plate and cover plate
gasket. Secure with the screws provided.
❒Align the three slots in the decorative shell with the
lamp holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
Shell Slot
❒If a wet location junction box was not used, caulk the
wall plate mounting surface with silicone weather
sealant.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
❒Turn power off at the fuse or circuit breaker.
❒Remove the existing light fixture.
❒Route the Light Control’s wires through the large
gasket hole.
Controls
WIRETHE LIGHT CONTROL.
Keep lamps at least
1" (2.5 cm) from the
sensor. Do not allow
Lens
the lamps to block
the lens.
❒Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
2
595-5612-08
TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has about 1 1/
period before it will detect motion. When first
turned on, wait about 1 1/
❒Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum RangeMaximum
minutes warm up
2
minutes.
2
RANGE
MINMAX
180°
Coverage Angle
❒Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor.
❒Walk through the coverage area
noting where you are when the
lights turn on (also, the LED will
flash several times when motion is detected). Move the sensor head up, down, or sideways
to change the coverage area.
Keep the sensor at least 1"
(2.5 cm) away from the lamps.
❒Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5 or 10 minutes).
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
Aim Sensor
Down for Short
Aim Sensor
Higher for Long
Clamp
Screw
Ball
Joint
Coverage
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . . Up to 180°
Electrical Load. . . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements. . . 120 VAC, 60 Hz
Operating Modes. . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . . 1 , 5, 10 minutes
DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
The detector is most sensitive to motion across its field
of view.
Motion
Sensor
Motion
Least Sensitive Most Sensitive
595-5612-08
3
TROUBLESHOOTING GUIDE
SYMPTOM
Lights will not come
on.
Lights come on
in daylight.
Lights come on for
no apparent reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Flood light is loose or
burned out.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turn-off is in effect
check after dark)
5. Incorrect circuit wiring, if this is a
new installation.
6. Re-aim the sensor to cover desired area.
1. Light Control may be installed in
a relatively dark location.
2. Light Control is in Test.
.
(re-
(Set control switch to an
ON-TIME position)
1. Light Control may be sensing
small animals or automobile traffic
(re-aim sensor)
2. Range is set too high.
(Reduce Range)
.
.
.
SYMPTOM
Lights stay on
continuously.
Lights flash on
and off.
POSSIBLE CAUSE
1. A flood lamp is positioned too close to
the sensor or pointed at nearby objects that cause heat to trigger the
sensor.
from the sensor or nearby objects)
2. Light Control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface.
3. Light Control is in Manual Mode.
(Reposition the lamp away
(Reposition sensor)
.
.
(Switch to Auto.)
1. Heat or light from the lamps may be
turning the Light Control on and off.
(Reposition the lamps away from the
sensor)
2. Heat being reflected from other objects may be affecting the sensor.
(Reposition sensor)
3. Light Control is in the Test mode and
warming up.
der these conditions)
4. Light may be leaking through the
floodlamp reflectors.
.
.
(Flashing is normal un-
.
(Replace the lamps
with new high quality PAR 38 lamps)
.
TECHNICAL SERVICE
(Do Not Send Products)
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the
problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
DESA Specialty Products™
P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service Specialty Products
* If contacting Technical Service, please have the following information available: Model Number, Date of
Purchase, and Place of Purchase.
No Service Parts Available for this Product
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province
to province.
For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected
at no charge to you. Light bulbs are not covered. To obtain a refund or a replacement, return the product to the place of purchase.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs and other expendable items
are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty
in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, or unauthorized
service.
This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that
a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY,
REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR
PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE
PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or
provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not
apply to you. Retain receipt for warranty claims.
TEN YEAR LIMITED WARRANTY
4
595-5612-08
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.