Heath Zenith Motion Sensing Diecast Metal Lantern User Manual

Motion Sensing
Diecast Metal Lantern
Dated receipt required for warranty replacement.
FEATURES
• Automatically comes on when motion is detected.
• Automatically turns light off.
• Photocell keeps the light off during daylight hours.
REQUIREMENTS
• The light control requires 120 volts AC.
NOTICE: Not to be used on light dimmer or timer-
controlled circuits.
Some electrical codes require installation by a
qualified electrician.
UNPACKING
Be sure to remove all contents from packaging and verify all items are present before assembling this light fixture. This package includes the following items:
• Lantern
• Three LED light bulbs
• Universal mounting bracket (X-Bar)
• Mounting hardware
• Wire nuts
• Owner’s Manual
INSTALLATION
For best performance, mount the fixture about 6 feet (1.8 m) above the ground.
1. Remove two decorative nuts.
2. Remove X-Bar.
3. Tighten mounting screws on X-Bar finger tight.
4. Attach X-Bar to junction box.
Lantern Base
Decorative Nut
X-Bar
X-Bar
Lantern Mounting Screw
Junction Box
Bracket Mounting Screw
Note: We recommend having an assistant help hold the lantern assembly during the wiring process.
© 2008 598-1338-01
WIRING
WARNING: Turn power off at circuit breaker
or fuse.
Note: All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means. Contact a qualified electrician
if there is any question as to the suitability of the system.
CAUTION: DO NOT connect the RED wire unless you want to control other lights from the motion sensor (see Optional Wiring).
Connect the fixture wires to the wires in the junction box. Twist the wires together and secure with wire connectors.
Recommended Grounding Method
Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire con­nector. Secure the other end of the “pigtail” with the GND screw on the X-bar.
Black
Green or
White
White
Black
Green or
Bare
Bare
One Motion Light
Light
Fixture
Two Motion Lights
Light
Fixture
Light
Fixture
Black to black
White to white
If you have metal junction box, you may not need the green “pigtail”. If you are unsure about the grounding method, consult your local building code.
2
598-1338-01
OPTIONAL WIRING
This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100 Watts, 260 Watts of additional lighting may be controlled by this sensor.
When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the marking which specifies the maximum lamp wattage for which the fixture is suitable.
Once you have selected the fixtures to be connected and determined their maximum ratings, add these rat­ings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325 Watts.
Wiring Diagram 1 – When wiring to control a standard light fixture: Strip the motion sensor’s red wire and connect to the standard light’s black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 2 – When wiring to control another motion sensing light fixture (Master / Slave):
the red wire in both light fixtures. Connect the red wire of the controlling (master) fixture to the red and black wires of the controlled (slave) fixture. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 3 – When wiring so either motion light turns on the both motion lights (Master / Master):
Strip the red wire in both light fixtures. Connect the red wire of one fixture to the red wire of the second fixture. Note: In most installations, an additional wire (same gage as existing house wire) will have to be installed in the house to connect the two fixtures as master / master. Connect all white wires together and all black wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Strip
White
Black
Green or
Bare
598-1338-01
(Standard)
White
Light
Fixture
Red
Wiring Diagram 1 Wiring Diagram 2
White
Black
Green
or Bare
Light
Fixture
Master
Light
Fixture
Wiring Diagram 3
Black
Green or
Bare
Master
Red
Fixture
Master Slave
Light
Fixture
Light
3
Red
Light
Fixture
1. Push the wires into the junction box. Make sure
FINAL ASSEMBLY
none of the wires get pinched.
2.
Slide the fixture assembly onto the mounting screws. Tighten decorative nuts removed in step 1 of Instal- lation section securely against fixture base.
Decorative Nut
Top Cover
Star Washer
Nut
3 Light Bulbs (60 Watt Maximum each)
Finial
Decorative Nut
Fixture Assembly
Mounting Screw
Junction Box
3. Caulk around fixture base with silicone weather sealant.
4. Install the three LED bulbs (included). Note: This fixture uses either LED or tungsten incandescent Type “B” bulbs with E12 candelabra base (60 Watt maximum each).
5. Insert threaded rod of finial through top cover. Slide star washer onto rod and thread the nut onto the rod. Tighten securely.
6. Place top cover onto fixture and attach using the two decorative nuts (included). Hand tighten only.
4
598-1338-01
TESTING AND ADJUSTMENTS
TEST 510DUSK
MINUTES TO DAWN
+
SEN
1. Turn on the circuit breaker and light switch.
Note: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on wait 1 1/2 minutes.
2. Set:
ON-TIME switch to TEST SENSITIVITY dial to Midway
Photocell
3.
Walk through the coverage area noting where you are when the lights turn on. In TEST mode, light will stay on for 5 seconds after sensing motion and then turn off.
4. Adjust the SENSITIVITY to increase or decrease the range as needed. Too much sensitivity may cause false triggering due to heat sources in the coverage area (see Adjustment of Coverage Area or Troubleshooting section).
5. Set the amount of ON-TIME you want the light to stay on after motion is detected (5 or 10 minutes) or...
Set the ON-TIME to the DUSK-to-DAWN setting
if you want the light to stay on all night, every night. The photocell will turn the light off during the day.
180°
6 ft.
(1.8 m)
30 ft.
(9.1 m)
Maximum Range Maximum Coverage Angle* (Top View)
The sensor is less sensitive to motion directly towards it and more sensitive to motion across coverage area.
Motion Motion
Sensor
Least Sensitive Most Sensitive
598-1338-01
5
OPERATION
MANUAL MODE
AUTO
TEST
Mode: On-Time Works: Day Night
Test Security Automatic Override Manual Override
Note: When first turned on wait about 1 1/2 minutes
for the circuitry to calibrate.
5 Seconds x x
5 or 10 Minutes x
Dusk-to-Dawn x
Until Dawn* x
* resets to Security mode at dawn.
MANUAL OVERRIDE MODE
Manual Override mode can only be activated at night when the ON-TIME switch is set to the 5 or 10 minute position.
Flip the light switch off for one sec­ond then back on to change from SECURITY mode to MANUAL OVERRIDE mode.
To return to SECURITY mode, either:
• turn the light off for one minute then turn it on, or...
• daylight will automatically reset the light to SECURITY mode.
1 Second OFF then...
... back on.
MODE SWITCHING SUMMARY
ON-TIME Switch at 5 or 10
SECURITY
MODE
* If you get confused while switching modes, turn the power off for one minute, then back on. After the calibra­tion time the control will be in the SECURITY mode.
minutes
Flip light switch off for one second then back on*
ADJUSTMENT OF COVERAGE AREA
The sensor on this light fixture detects “motion” by the movement of heat across the coverage area. However, following are examples of objects that also produce heat and can cause the sensor to trigger:
• Pools of Water • Air Conditioners
• Dryer Vents • Animals
• Heating Vents • Automobile Traffic If you suspect that a heat source of this type is trig-
gering the sensor, reduce the sensitivity.
SPECIFICATIONS
Range ........................... Up to 30 ft. (9.1 m) [varies
Sensing Angle ..............180°
Electrical Load .............. Up to 180 Watt Maximum
Bulb Type ...................... E12 Candelabra Base,
Sensor Capacity ...........360 Watt (3.0 A) Maximum
Power Requirements .... 120 VAC, 60 Hz
Operating Modes .......... TEST, SECURITY, AUTO-
ON-Timer ...................... 5 or 10 minutes
Test Timer ..................... 5 Seconds
Automatic
Override Timer .............. Dusk-to-Dawn
Manual
Override Timer .............. Until Dawn
6
with surrounding tempera­ture].
LED or Tungsten Incan­descent
Type “B”, 60 Watt Maxi­mum LED or Tungsten Incandescent
Tungsten Incandescent
MATIC OVERRIDE and MANUAL OVERRIDE
598-1338-01
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
Lights will not come on.
Lights come on in daylight.
Lights come on for no apparent reason.
Lights stay on continu­ously.
Lights flash on and off.
Light does not stay on in Manual mode.
1. Light switch is turned off.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect.
5. Incorrect circuit wiring, if this is a new installation.
1. Light control may be installed in a relatively dark location.
2. Light control is in TEST.
Light control may be sensing small animals or automobile traffic.
1. The sensor may be picking up a heat source like an air vent, dryer vent, or brightly painted, heat-reflective surface.
2. Sensor is in Automatic Override or Manual Override mode.
1. Heat being reflected from other objects may be affecting the sensor.
2. Sensor is in the Test mode.
Nearby large, light-colored objects reflecting light may trigger the shut-off feature.
1. Turn light switch on.
2. Check lamp and replace if burned out.
3. Replace fuse or turn circuit breaker on.
4. Recheck after dark.
5. Verify wiring is correct.
1. The fixture is operating normally under these conditions.
2. Set control switch to 5 or 10 minutes or Dusk-to­Dawn.
Reduce sensitivity.
1. Reduce sensitivity.
2. Set control switch to 5 or 10 minutes.
1. Reduce sensitivity.
2. While in TEST mode, light only stays on for 5 seconds.
Do not point other lights at the sensor.
598-1338-01
7
TWO YEAR LIMITED WARRANTY
Product will be free of defect due to workmanship for a period of two (2) years. If product fails within the stated life, return defective product to retailer of Lights of America.
Warranty terms and conditions of retailer apply. Warranty and guarantee void if product is misused. If replacement product is not available at retail store, please return product in the original package, along
with a copy of the dated sales receipt, description of the problem, and your name and return address to the manufacturer at the address listed below:
Lights of America 611 Reyes Drive Walnut, CA 91789 Attn: Consumer Affairs Dept.
Distributed by:
611 Reyes Drive
Walnut, California 91789
Tel: (800) 321-8100 / (909) 594-7883
Fax: (909) 594-6758
Website: www.lightsofamerica.com
8