turn the power off for one minute, then back
on. After the calibration time the control will
be in the AUTO mode.
DualBrite® Dimmer Control
Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting
OFF disables this feature. The motion sensing
features will continue to work as described
in this manual. If motion is sensed, the light
turns on full bright for the ON-TIME (1, 5, or
10 minutes) then returns to dim mode.
INSTALLATION
For best performance, mount the fixture about
6 feet (1.8 m) above the ground.
WARNING: Turn power off at circuit
breaker or fuse.
1. Remove two nuts.
2. Remove
Mounting Plate.
SENS
MIN
Wire Path
5. Attach mounting
plate to junction box.
MAX
4. Set sensitivity control on back
of fixture to mid-position.
Ground Screw
This fixture comes with a universal mounting
bracket. It is pre-assembled on the fixture to
fit the majority of junction box applications.
However, if the slots on the mounting plate
do not line up with the junction box screw
holes:
1. Remove the fixture mounting screws from
the mounting plate. Note: Do not remove
the ground screw.
2. Attach ground wire “pigtail” to ground
screw on mounting plate (See Recom-mended Grounding Method for additional
information).
3. Flip the mounting plate over.
3. Tighten screws
finger tight.
2
598-1207-01
4. Rotate the mounting plate so the wire path
is on the upper right. Note: The wire path
on the mounting plate must be located
as shown below to allow the wires on the
back of the fixture to pass through.
5. Reinstall the fixture mounting screws and
attach the mounting plate to the junction
box as shown.
Wire Path
Ground Screw
Wire Path
White
Light
Fixture
Black
Green
or Bare
Two Motion Lights
Light
Fixture
❒ Twist the junction box wires and the
fixture wires together as shown below.
Secure with wire connectors. If you have
a metal junction box, you may not need
the green “pigtail”. If you are unsure about
the grounding method, consult your local
building code.
Fixture Screws
As Shipped Flipped and
Rotated
WIRING
Note: All wiring should be run in accordance
with the National Electrical Code through
conduit or another acceptable means.
Contact a qualified electrician if there is
any question as to the suitability of the
system.
CAUTION: DO NOT connect the RED
wire unless you want to control other
lights from the motion sensor.
Black
Green
or Bare
White
Light
Fixture
Connect the fixture wires to the wires in the
junction box. Twist the wires together and
secure with wire connectors.
Recommended Grounding Method
Use a green ground “pigtail” (not provided) and
twist one end together with the bare fixture wire
and the box ground wire. Secure with a wire
connector. Secure the other end of the “pigtail”
with the GND screw on the mounting plate.
Black to black
White to white
598-1207-01
One Motion Light
3
OPTIONAL WIRING
This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100
Watts, 260 Watts of additional load may be controlled by this sensor.
When determining what a fixture is rated for, do not simply look at the rating on the lamp in
the fixture. Look at the marking which specifies the maximum lamp wattage for which the
fixture is suitable.
Once you have selected the fixtures to be connected and determined their maximum ratings,
add these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and
75 Watts respectively, you have a total load of 325 Watts.
Wiring Diagram 1 – When wiring to control a standard light fixture: Strip the motion sensor’s
red wire and connect to the standard light’s black wire. Connect all white wires together.
Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 2 – When wiring to control another motion sensing light fixture (Master /
Slave): Strip the red wire in both light fixtures. Connect the red wire of the controlling (master)
fixture to the red and black wires of the controlled (slave) fixture. Connect all white wires
together. Total fixture ratings must not exceed 360 Watts (3.0 A).
White
Black
Green
or Bare
Light
Fixture
Wiring Diagram 1
Red
(Standard)
Light
Fixture
White
Black
Green
or Bare
MasterSlave
Light
Fixture
Wiring Diagram 2
Red
Light
Fixture
4
598-1207-01
COMPLETE THE
INSTALLATION
❒ Stuff the wires into the junction box. Make
sure the wires from the fixture go through
the wire path, and no wires get pinched.
TESTING
❒ Turn on the circuit breaker and light
switch.
Note: Sensor has a 1 1/2 minute warm up pe-
riod before it will detect motion. When
first turned on wait 1 1/2 minutes.
Note: Meets the ENERGY STAR® guidelines
when DualBrite® function is off.
❒ Switch the on-time to TEST position and
DualBrite® switch to the OFF position.
Slide the fixture onto the
mounting screws and
tighten nuts.
Junction
Box
❒Caulk fixture mounting surface with
silicone weather sealant. You may want
to wait until you have completed the tests
and adjustments on page 6.
❒ Install one 100 W max. light bulb.
TEST 1 5 10 MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Avoid aiming the control at:
• Pools of water or objects that change
temperature rapidly, such as heating vents and air conditioners. These heat sources
could cause false triggering.
• Areas where pets or traffic may trigger
the control.
• Nearby large, light-colored objects reflect-
ing daylight may trigger the shut-off feature.
Do not point other lights at the sensor.
150°
6 ft.
(1.8 m)
30 ft.
(9.1m)
Maximum Range Maximum
Coverage Angle
598-1207-01
5
The detector is less sensitive to motion directly towards it and more sensitive to across
motion.
Motion
Sensor
Motion
Least Sensitive Most Sensitive
❒ Walk through the coverage area noting
where you are when the lights turn on.
Move the sensor head left or right to
change the coverage area.
Note: Grasp the sensor
only as shown and turn
the entire sensor. Any
other method may
damage the sensor.
Do not force it past
the stops.
SPECIFICATIONS
Range . . . . . . . . . . . Up to 30 ft. (9.1 m)
[varies with surrounding
temperature]
Sensing Angle . . . . . Up to 150°
Electrical Load . . . . . Up to 1 00 Watt
Maximum Tungsten
Incandescent
Sensor Capacity . . . Up to 360 Watts (3.0 A.)
Maximum Tungsten
Incandescent
Power Requirements 120 VAC, 60 Hz
Operating Modes . . . TEST, AUTO, and
MANUAL MODE
Time Delay . . . . . . . 1, 5, 10 minutes
DualBrite® Timer . . . Off, 3, 6 hours, dusk-to
dawn
HeathCo LLC reserves the right to discontinue
products and to change specifications at
any time without incurring any obligation
to incorporate new features in products
previously sold.
240°
Sensor Aiming
Adjustment Angle
❒ If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.
❒ Set the amount of TIME you want the
light to stay on after motion is detected.
(1, 5, or 10 minutes).
❒ Set the amount of time after dusk you
want the lights on accent level.
6
598-1207-01
TROUBLESHOOTING GUIDE
If you experience a problem with your coach light, follow this guide before returning it to
the retailer.
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turn-off is in effect
(recheck after dark).
5. Incorrect circuit wiring, if this
is a new installation.
6. Re-aim the sensor to cover
desired area.
1. Light control may be installed
in a relatively dark location.
2. Light control is in Test. (Set
control switch to an ON-TIME
position.)
1. Light control may be sensing
small animals or automobile
traffic (re-aim sensor).
2. Sensitivity is set too high.
(Reduce sensitivity.)
SYMPTOM
Light stays on
continuously.
Light flashes
on and off.
Light does not
stay on in Manual mode.
POSSIBLE CAUSE
1. The sensor is pointed toward
a heat source like an air vent,
dryer vent, or brightly-painted
heat-reflective surface. (Re-aim
sensor.)
2. Light control is in Manual Mode.
(Switch to Auto.)
3. Light control is in DualBrite®
mode.
4. Sensitivity is set too high. (Re-
duce sensitivity.)
1. Sensor is in the Test mode.
(While in TEST mode, light only
stays on for 5 seconds.)
2. Heat being reflected from other
objects may be affecting the
sensor. (Re-aim sensor.)
1. Nearby large, light-colored
objects reflecting light may
trigger the shut-off feature. Do
not point other lights at the
sensor.
No Service Parts Available for this Product
598-1207-01
See your Canadian Tire retailer for warranty information.
7
DualBrite® Luces de
Coches Detectores de
Movimiento para
Canadian Tire
FUNCIONAMIENTO
Modalidad:A tiempo:Trabaja: Día Noche
Prueba
Autom.
Manual
Adorno
*Se pone en Automático al amanecer.
5 seg.xx
1, 5 ó 10 min.x
Hasta el
amanecer*
3, 6 hrs, hasta
el amanecer
x
x
Cumple con las normas ENERGY STAR® cuando la función
DualBrite® está apagada.
Características
• La luz se prende cuando se detecta movimiento.
• Apaga la luz automáticamente.
• La fotocélula mantiene la luz apagada
durante las horas del día.
Este paquete contiene:
• Farol
• Soporte universal de fácil uso
• Ferretería de montaje
• Conectores de alambre
Requisitos
• El control de luz requiere 120 VCA.
• Para usar el Sobrecontrol Manual, conecte
el control con un interruptor.
• Algunos códigos requieren instalación
por un electricista calificado.
Nota: Cuando lo prenda por primera vez es-
pere 1 1/2 minutos para que el circuito
se claibre.
PRUEBA
Ponga el interruptor de tiempo (ON-TIME), al fondo del
detector, en la posición de
prueba (TEST) y DualBrite®
a apagado (OFF).
AUTOMATICO
Ponga el interruptor de tiempo (ON-TIME) en la posición
de 1, 5 ó 10 minutos.
MODO MANUAL
El modo manual funciona
sólo por la noche porque la
luz del día pone al detector
en modo AUTOMATICO.
Apague el interruptor por
un segundo y vuélvalo a
prender.
TEST 1 5 10
TEST 1 5 10
1 segundo
APAGADO
luego...
El modo manual funciona
sólo cuando el interruptor
de tiempo (ON-TIME) está
en la posición de 1, 5 ó 10
minutos.