Heath Zenith BL-5511 User Manual

Compact 150 Watt
MANUAL MODE
AUTO
TEST
Motion Sensing Halogen
Model BL-5511
The Motion Sensor Quartz Security Light turns on 150 watts of quartz-halogen lighting when motion is detected and then, after a selectable period of time, automati­cally turns the lighting off. The built-in photocell keeps the lighting off during daylight hours.
This package includes:
OPERATION
Mode: On-Time Works: Day Night
Test Auto Manual
Note: When first turned on wait about 11/2 minutes for
the circuitry to calibrate.
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
Put the ON-TIME switch in the 10 minute position.
5 Seconds x x
10 Min x
Until Dawn* x
* resets to Auto Mode at dawn.
TEST
ON-TIME
10 TEST
AUTO
ON-TIME
10 TEST
MANUAL MODE
Plate
Halogen
Bulb
Sensor
Light Fixture
Requirements
• The light control requires 120-volts AC. Do not con-
nect through a dimmer or other electronic switch.
• If you want to use Manual Mode, the control must be wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
• The backplate has knockouts so the sensor can be mounted on most junction boxes.
• In some applications a universal adaptor plate may be needed. Adaptors are available at Home Centers and Electrical Supply Stores.
Cover Plate
Gasket
4 Screws
(2 sizes)
3 Wire
Connectors
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON­TIME switch in the 10 position.
1 Second OFF
then...
... back on.
Mode Switching Summary
Move ON-TIME Switch
to 10 minutes
Flip switch off for
one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time (11/2 min.) the control will be in the AUTO mode.
© 2007 HeathCo LLC 598-1324-01
INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
For best performance, locate the fixture about 8 ft. (2.4 m) above the ground.
CAUTION: The sensor must be mounted below the lamp housing for wall installations.
To insert the new bulb, push the bulb into the right
socket so the bulb fits completely into the left socket.
Check that the bulb is seated properly. ❒ Close the glass cover. Replace screw.
Wire the Light ControL
WARNING: Turn power off at the fuse or circuit
breaker.
❒ Drill out the holes if needed
to mount the backplate to the junction box.
CAUTION to avoid fire or burn hazards:
• Allow fixture to cool before touching. The bulb and fixture operate at high temperatures.
• Keep fixture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).
• Re-lamp with type T 150W (or less) halogen 120 VAC lamp only.
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
Rotate the sensor head to-
wards the clamp screw joint.
Clamp Screw
Controls
Remove the existing light fixture. Strip about 5/8" insulation from the existing junction
box wiring.
Route the light control’s wires through the large
hole in the gasket.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Black to Black
Junction box ground wire to green ground wire on fixture.
White to White
Cover Plate
Gasket
Then rotate the sensor
head counterclockwise 180° so the controls face down.
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
BuLB instaLLation and reLaMping
When relamping, turn power off and let the fixture
cool.
Remove the screw that holds the glass cover shut.
Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.
Mount the Light ControL
Align the light control cover plate and cover plate
gasket and the junction box. Insert and tighten the mounting screws.
If not installed on a weatherproof box or if an adaptor
plate is used, caulk the wall plate and mounting surface with silicone weather sealant.
RIGHT WRONG
The halogen light must be mounted horizontally (+/- 4°).
2
598-1324-01
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor requires about 1 1/2 minutes to calibrate
before it will detect motion. When first turned on, wait about 1 1/2 minutes.
Set the ON-TIME control to the TEST position.
ON-TIME
10 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
110°
8 ft.
(2.4 m)
Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor to aim.
Walk through the coverage
area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover­age area. Keep the sensor at
least 1" (25 mm) away from the lamps.
Secure the sensor head into
position by tightening the clamp screw. Do not over-
tighten the screw.
Set the ON-TIME control to 10 minutes.
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Clamp
Ball Joint
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 50 ft. (15.2 m); [varies with
surrounding temperature]
Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up to 150 Watts Maximum
tungsten Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 10 minutes
Sensitivity . . . . . . . . . . Adjustable
Replacement lamp . . . . T 150W (or less) halogen 120
VAC
50 ft.
Maximum
Range
The control is most sensitive to motion across it.
Motion
(15.2 m)
Maximum
Coverage Angle
Motion
Sensor
Least Sensitive Most Sensitive
598-1324-01
HeathCo LLC reserves the right to discontinue prod­ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
3
TROUBLESHOOTING GUIDE
SYMPTOM Light will not
come on.
Light comes on in daylight.
Light comes on for no apparent reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Halogen lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect (Recheck after dark).
5. Incorrect circuit wiring, if this is a new installation.
6. Not aimed correctly (Re-aim the sensor to cover desired area).
1. Light control may be installed in a relatively dark location.
2. Light control is in TEST (Select 1, 5 or 10 minutes for AUTO time).
1. Light control’s sensor may be detect ing small animals, swaying trees, or automobile traffic (Re-aim sensor).
2. Sensitivity is set too high (Reduce sensitivity).
SYMPTOM Light stays on
continuously.
Light flashes on and off.
-
POSSIBLE CAUSE
1. The halogen lamp is positioned too close to the light control’s sensor or pointed at nearby objects that cause heat to trigger the sensor (Reposition
the lamp away from the sensor or nearby objects).
2. Light control’s sensor is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface (Reposition sensor).
3. On-time set too high (Reduce Time setting).
1. Heat or light from the halogen lamp may be turning the light control on and off (Reposition the lamp away from the sensor).
2. Heat being reflected from other objects may be affecting the light control (Re-aim sensor).
3. Light control is in the TEST mode and warming up (Flashing is normal under these conditions).
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to: HeathCo LLC, P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service * If contacting Technical Service, please have the following information available: Model Number, Date of Pur­chase, and Place of Purchase.
No Service Parts Available for this Product
TWO YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for incon­venience, installation, setup time, loss of use, unauthorized service, or return shipping charges. This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HEATHCO LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential dam­ages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
4
598-1324-01
Loading...
+ 8 hidden pages