Security Light with
Motion-activated Sensor
This product is ENERGY STAR® compliant
when used with 120 Watt bulbs.
Models 52-4075 / 52-4076
Installation and Operating
Instructions
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
This package includes:
Lamp Holders
Cover
Plate
4 Mounting
Screws (2 sizes)
OPERATION
Mode: On-Time: Works: Day Night
Test
Normal
Manual
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put the ON-TIME switch on the bottom
of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
5 Sec x x
1, 5, 10 min. x
Until Dawn* x
* resets to Auto Mode at dawn.
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
MANUAL MODE
1 Second OFF
then...
Sensor
Gasket
Light Control
2 Wire
Connectors
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
• Some codes require installation by a qualified elec-
trician. Please check the codes in your area.
• This product is intended for use with a junction box
marked for use in wet locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at home centers
and electrical supply stores.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
... back on.
Mode Switching Summary
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
598-1284-00
INSTALLATION
Wire the Light ControL
For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about
8 feet (2.4 m) above the ground.
❒ Drill the holes needed
to mount the backplate
to the junction box.
Wall MountEave Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
❒ Rotate the sensor head towards the clamp screw
joint.
Control Switch
❒ Turn power off at the fuse or circuit breaker.
❒ Remove the existing light fixture.
❒ Route the Light Control's wires through the large
gasket hole.
❒ Connect the junction box wires to the Light Control
wires. Twist together and secure with a wire
connector.
Black to
White to
White
Black
Gasket
Mount the Light ControL
❒ Align the Light Control cover plate and the junction
box holes. Secure with the mounting screws.
❒ If not installed on a weatherproof box or if an adaptor
plate (not included) was used, caulk the wall plate
and mounting surface with silicone.
Avoid water damage and
electrical shock - keep lamp
holders below horizontal.
Joint Clamp
❒ Then rotate the sensor head clockwise 180° so the
controls face down.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Lock nuts
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the floodlamps, do not overtighten.
2
Keep lamps at
least 1" (25 mm)
from the sensor.
598-1284-00
TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on, wait 1 1/2 minutes.
❒
Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
60 ft.
(18.3 m)
SENS
MIN MAX
110°
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the coverage area. Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒ Adjust the SENSITIVITY
as n eed ed. Too mu ch
sensitivity may increase false
triggering.
❒ Secure the sensor head
by tightening the clamp
screw. Do not overtighten the
screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Clamp
Screw
Ball
Joint
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 110°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
Maximum Range Maximum
Coverage Angle
The detector is most sensitive to motion across its field
of view.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
598-1284-00