Heath Zenith 52-4041-4, 52-4042-2 User Manual

MANUAL MODE
AUTO
TEST
Motion-Activated Sensor
Models 52-4042-2 / 52-4041-4
Features
• Turns on lighting when motion is detected.
• On-Time control allows length of time light stays on to be adjusted.
• Photocell keeps light off during daylight hours.
• LED flashes day or night to indicate motion has been detected.
This package includes:
Lamp
Holders
Rubber Plug
OPERATION
Mode: On-Time Works: Day Night
Test Auto Manual
Note: When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or 10 minute position.
Manual mode only works at night because daylight returns the sensor to AUTO.
5 Seconds x x
1, 5, or 10 Minutes x
To Dawn* x
* resets to Auto Mode at dawn.
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
MANUAL MODE
Cover
Plate
Mounting Bolt
(3 sizes included)
Sensor
Light Control
Mounting Strap
6 Screws
Plastic Hanger
2 Wire
Connectors
Gasket
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
Some codes requi r e in s tallation by a
qualified electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
1 Second OFF
then...
... back on.
Mode Switching Summary
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
© 2008 HeathCo LLC 598-1198-01
INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
❒ Route the light control’s wires through the large
gasket holes.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Wall Mount
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
Swing the sensor head towards the clamp screw
joint.
Clamp Screw
Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
Eave Mount
Controls
Mounting
Strap
Junction box ground wire to green ground screw on fixture.
Black to Black
White to White
Rubber
Plug
Mounting
Bolt
Gasket
Mount the Light ControL
Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
Push the rubber plug firmly into place. If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone weather sealant.
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
Wire the Light ControL
WARNING: Turn power off at the fuse or circuit
breaker.
❒ Remove the existing light fixture. Install the mounting strap as shown using two screws
that fit your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
To avoid water damage and electrical shock, keep lamp holders 30° below horizontal.
Keep lamps at least 1" (2.5 cm) from the
Lock Nut
❒ Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.
sensor. Do not allow the lamps to block the lens.Lens
2
598-1198-01
on, wait 1 1/2 minutes.
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on, wait 1 1/2 minutes.
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range Maximum Coverage Angle
The detector is most sensitive to motion across its field of view.
RANGE
MIN MAX
150°
Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor.
Walk through the coverage
area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected). Move the sensor head up, down, or sideways to change the cover­age area. Keep the sensor at
least 1" (2.5 cm) away from the lamps.
Adjust the RANGE as needed.
RANGE set too high may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
Down for Short
Higher for Long
Clamp Screw
Ball Joint
Aim Sensor
Coverage
Aim Sensor
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . Up to 150°
Electrical Load . . . . . . Up to 300 Watt Maximum In-
candescent [Up to 150 Watt
maximum each lamp holder.] Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
Operating temperature
range . . . . . . . . . . . . . -22 to 120°F (-30 to 49°C)
HeathCo LLC reserves the right to discontinue prod­ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
Motion
Motion
Sensor
Least Sensitive Most Sensitive
598-1198-01
3
Loading...
+ 5 hidden pages