Heath Zenith 5213, 5212 User Manual

Instant Motion Sensor
MANUAL MODE
AUTO
TEST
Light Control
Models 5212 and 5213
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
Requirements
• The Light Control requires a properly installed and working light fixture, operating on 120 volts AC.
• If you want to use Manual Mode, the fixture must be wired through a switch.
Parts
Package includes:
• Motion Sensor
• Lamp Adapter (5213)
• Two mounting screws
Typical Installation
The lamp module should only be used with Listed lamp fixtures. Never use a light bulb with a higher wattage rating than the rating of your fixture.
OPERATION
Mode: On-Time: Works: Day Night
Test 5 Sec x x Auto 1, 5, 10 min. x Manual Until Dawn* x
* resets to Auto Mode at dawn.
TEST
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
AUTO
Put the ON-TIME switch in the 1, 5 or 10 minute position.
MANUAL OVERRIDE
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.
Manual mode works with the ON-TIME switch in the 1, 5, or 10 position.
ON-TIME
10 5 1 TEST
ON-TIME
10 5 1 TEST
1 Second OFF
then...
Existing Light Fixture
... back on.
Mode Switching Summary
Lamp Adapter
Sensor Module
© 2005 DESA Specialty Products™ 595-5734-04
Sensor
Cord
Floodlamp
(not included)
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
Move ON-TIME Switch
to 1, 5 or 10 minutes
Flip switch off for
one second then
back on
INSTALLATION
.
Turn power off at the fuse or circuit breaker.
This model Instant Motion Sensor Light Control can be used with many indoor or outdoor light fixtures where the motion sensing feature is desired.
Keep the lamp at least 1"
(25mm) from the sensor
and cord.
Mounting Sensor
Wall Mount Ceiling Mount
Mount the sensor 5 to 9 feet (1.5 to 2.7 meters) above
the ground. Place the sensor below or beside the
lighting fixture so that the light from the fixture will not hit the sensor. Secure the sensor to the
wall with the screws provided. It will be necessary to tilt the sensor head to the side when mounting.
NOTE: Do not stretch the coils too tight when installing the remote sensor. The coils are needed to create a drip loop to prevent water from running into the fixture or the sensor.
Open the light fixture if it
is necessary. Remove the light bulb. Screw in the lamp module and replace the bulb.
Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
NOTE: Mounting the sensor directly above the lamps
may increase false triggering.
Plug the adapter
cord(s) into the sensor module. The adapter cord's plug is polarized for proper installation.
The sensor/control is capable of controlling two lamp
adapters. This illustration shows a typical installation with two lamp adapters controlling PAR-38 lamps. Note the sensor is below the lamps and there is sufficient cord from the adapters to form a drip loop to prevent water from running down the cords and into the sensor. Also,
th e la mps mu st st ay at least 1" (25mm) from the sensor.
2
595-5734-04
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
The detector is less sensitive to motion directly towards it and more sensitive to cross motion.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned on or when switching from Manual to Auto mode wait 1 1/2 minutes.
Turn the SENSITIVITY (SENS) control to the mid
position and the ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
SENS
MIN MAX
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
5 to 9'
(1.5-2.7 m)
60 ft.
(18m)
110°
Motion
Sensor
Motion
Least Sensitive Most Sensitive
Walk through the coverage
area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover­age area.
Adjust the SENSITIVITY as
needed. Too much sensitivity may increase false triggering.
Set the amount of TIME you
want the lights to stay on after motion is detected (1, 5, or 10 minutes).
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 60' (18m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up to 150 Watts Maximum (per
adapter) Incandescent. Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 1 , 5, 10 minutes
Sensitivity . . . . . . . . . . Adjustable
DESA Specialty Products™ reserves the right to dis­continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
Maximum Range Maximum Coverage Angle
595-5734-04
3
TROUBLESHOOTING GUIDE
SYMPTOM Light will not
come on.
Light comes on in daylight.
Light comes on for no apparent reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect (recheck after
dark)
5. Re-aim the sensor to cover desired area.
6. Cable not fully plugged in.
1. Light Control may be installed in a relatively
2. Light Control is in Test (Set control switch
1. Light Control may be sensing small animals
2. Sensitivity is set too high (Reduce sensitiv-
.
dark location.
to an ON-TIME position).
or automobile traffic
ity).
(re-aim sensor).
SYMPTOM Light stays on
continuously.
Light flashes on and off.
POSSIBLE CAUSE
1. A sensor is positioned too close to the lamp or pointed at nearby objects that cause heat to trigger the sensor (Reposition the lamp away from the sensor or nearby objects).
2. Light Control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface (Reposition sensor).
3. Sensor is in Manual Mode (Set to Auto Mode).
1. Heat or light from the lamp may be turning the Light Control on and off (Reposition the
sensor away from the light)
2. Heat being reflected from other objects may be affecting the sensor (Reposition sensor).
3. Light Control is in the Test mode and warm ing up (Flashing is normal under these conditions).
.
-
TECHNICAL SERVICE
(Do Not Send Products)
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™ P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service Specialty Products
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur­chase, and Place of Purchase.
No Service Parts Available for this Product
This is a "Limited Warranty" which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of five years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Light bulbs are not covered. To obtain a refund or a replacement, return the product to the place of purchase. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, or unauthorized service. This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRE­SENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Retain receipt for warranty claims.
FIVE YEAR LIMITED WARRANTY