* If you get confused while switching modes, turn the
power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
Move ON-TIME Switch
to 1, 5 or 10 minutes
Flip switch off for
one second then
back on
INSTALLATION
.
❒ Turn power off at the fuse or circuit breaker.
This model Instant Motion Sensor Light Control can be
used with many indoor or outdoor light fixtures where
the motion sensing feature is desired.
Keep the lamp at least 1"
(25mm) from the sensor
and cord.
Mounting Sensor
Wall MountCeiling Mount
❒ Mount the sensor 5 to 9 feet (1.5 to 2.7 meters) above
the ground. Place the sensor below or beside the
lighting fixture so that the light from the fixture
will not hit the sensor. Secure the sensor to the
wall with the screws provided. It will be necessary
to tilt the sensor head to the side when mounting.
NOTE: Do not stretch the coils too tight when installing
the remote sensor. The coils are needed to create a
drip loop to prevent water from running into the fixture
or the sensor.
❒ Open the light fixture if it
is necessary. Remove the
light bulb. Screw in the lamp
module and replace the
bulb.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
NOTE: Mounting the sensor directly above the lamps
may increase false triggering.
❒ Plug the adapter
cord(s) into the
sensor module. The
adapter cord's plug
is polarized for proper
installation.
❒ The sensor/control is capable of controlling two lamp
adapters. This illustration shows a typical installation
with two lamp adapters controlling PAR-38 lamps.
Note the sensor is below the lamps and there is
sufficient cord from the adapters to form a drip
loop to prevent water from
running down the cords
and into the
sensor. Also,
th e la mps
mu st st ay
at least 1"
(25mm) from
the sensor.
2
595-5734-04
TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
The detector is less sensitive to motion directly towards
it and more sensitive to cross motion.
NOTE: Sensor has a 1 1/2 minute warm up period
before it will detect motion. When first turned
on or when switching from Manual to Auto
mode wait 1 1/2 minutes.
❒ Turn the SENSITIVITY (SENS) control to the mid
position and the ON-TIME control to the TEST
position.
ON-TIME
10 5 1 TEST
SENS
MIN MAX
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
may trigger the shut-off feature. Do not point other
lights at the sensor.
5 to 9'
(1.5-2.7 m)
60 ft.
(18m)
110°
Motion
Sensor
Motion
Least Sensitive Most Sensitive
❒ Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the coverage area.
❒ Adjust the SENSITIVITY as
needed. Too much sensitivity
may increase false triggering.
❒ Set the amount of TIME you
want the lights to stay on after
motion is detected (1, 5, or 10
minutes).
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 60' (18m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . Up to 110°
Electrical Load . . . . . . . Up to 150 Watts Maximum (per
adapter) Incandescent.
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 1 , 5, 10 minutes
Sensitivity . . . . . . . . . . Adjustable
DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any
time without incurring any obligation to incorporate new
features in products previously sold.
Maximum Range Maximum
Coverage Angle
595-5734-04
3
TROUBLESHOOTING GUIDE
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Lamp is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect (recheck after
dark)
5. Re-aim the sensor to cover desired area.
6. Cable not fully plugged in.
1. Light Control may be installed in a relatively
2. Light Control is in Test (Set control switch
1. Light Control may be sensing small animals
2. Sensitivity is set too high (Reduce sensitiv-
.
dark location.
to an ON-TIME position).
or automobile traffic
ity).
(re-aim sensor).
SYMPTOM
Light stays on
continuously.
Light flashes on
and off.
POSSIBLE CAUSE
1. A sensor is positioned too close to the lamp
or pointed at nearby objects that cause heat
to trigger the sensor (Reposition the lamp away from the sensor or nearby objects).
2. Light Control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface
(Reposition sensor).
3. Sensor is in Manual Mode (Set to Auto Mode).
1. Heat or light from the lamp may be turning
the Light Control on and off (Reposition the
sensor away from the light)
2. Heat being reflected from other objects may be
affecting the sensor (Reposition sensor).
3. Light Control is in the Test mode and warm
ing up (Flashing is normal under these conditions).
.
-
TECHNICAL SERVICE
(Do Not Send Products)
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the
problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
DESA Specialty Products™
P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service Specialty Products
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
This is a "Limited Warranty" which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.
For a period of five years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no
charge to you. Light bulbs are not covered. To obtain a refund or a replacement, return the product to the place of purchase.Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs and other expendable items are not
covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety.
This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, or unauthorized service.
This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a
customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE,
AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF
DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT
LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Retain receipt for warranty claims.
FIVE YEAR LIMITED WARRANTY
4
595-5734-04
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.