U.S. Patents 4,793,322; 4,875,464; 5,000,162 and Patents Pending
Canadian Patent 1,297,746
A.G.A. Design Certified/CGA Certified and
Underwriters Laboratories Listed. See
Approvals Tabel on Page 1.
WARNING
IF THE INFORMATION IN
THESE INSTRUCTIONS IS
NOT FOLLOWED EXACTLY, A
FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY,
OR LOSS OF LIFE.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A.
Copyright 1997,
Heat-N-Glo Fireplace Products, Inc.
6665 West Highway 13, Savage, MN 55378
READ THIS MANUAL BEFORE INSTALLING
OR OPERATING THIS APPLIANCE. THIS
INSTALLERS GUIDE MUST BE LEFT WITH
APPLIANCE FOR FUTURE REFERENCE.
WARNING: IMPROPER
INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE.
REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL
INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENGY, OR THE GAS SUPPLIER.
1.This appliance may be installed in an
aftermarket, permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
2. This appliance is only for use with the
type of gas indicated on the rating
plate. This appliance is not convertible
for use with other gases, unless a
certified kit is used.
Please contact your Heat-N-Glo Fireplace
dealer for any questions or concerns. For the
number of your nearest Heat-N-Glo dealer,
please call 612-890-8367.
446-982-A 8/97
SAFETY AND WARNING INFORMATION
LIMITED 10 YEAR WARRANTY
HEAT-N-GLO GAS FIREPLACE PRODUCTS
In order to presumptively establish the dates to which your HEAT-N-GLO Limited 10 Year Warranty runs, you
must mail the completed warranty card to HEAT-N-GLO FIREPLACE PRODUCTS, INC., 6665 West
Highway 13, Savage, MN 55378, within 60 days of the date of fireplace installation. If you fail to do so, you
may be required to prove the date of installation before warranty work can be performed.
The warranty exclusions and limitations of liability are effective upon installation of the fireplace.
Subject to the conditions set forth herein, HEAT-N-GLO FIREPLACE PRODUCTS, INC. ("HEAT-N-GLO")
extends the following warranty with respect to HEAT-N-GLO Gas Fireplace Products.
If HEAT-N-GLO is reasonably satisfied that any part or portion of the fireplace covered by this Limited Warranty
is defective in material or workmanship under normal use and service as described in the Owners Guide,
HEAT-N-GLO will take the following actions:
1.If the defect is reported during the first year from the date of installation (stainless steel burners and fiber logs
are covered for 3 years), HEAT-N-GLO will replace or repair the defective components at its sole expense. The
decision whether to replace a component shall be made at HEAT-N-GLO's sole discretion. This Limited
Warranty does
not cover components broken during shipping, misuse or careless handling. HEAT-N-GLO
READ and UNDERSTAND all instructions carefully before starting the installation.
shall be not responsible for any indirect, incidental, or consequential damages or for any costs other than those
incurred by HEAT-N-GLO to repair or replace the defective component. If components (including venting)
other than factory approved components are used, all warranty and liability on the fireplace is voided. Defects
reported after the first year will not be covered by warranty unless they fall within the purview of
paragraph 2 or 3 below.
2.If the following defects are reported during the second year after the date of installation, HEAT-N-GLO will
supply replacement parts at the current wholesale price: defective electrical or manual components, optional
components or accessories, and glass panels (not including glass panels broken during misuse or careless
handling). HEAT-N-GLO shall not be responsible for any labor, transportation or other costs. Furthermore,
HEAT-N-GLO shall not be liable for any indirect, incidental or consequential damages.
3.HEAT-N-GLO will replace or repair a defective firebox or heat exchanger, at any time during the 10 years from
the date of installation. The decision whether to replace the defective component shall be made at
HEAT-N-GLO's sole discretion. HEAT-N-GLO shall not be responsible for any indirect, incidental or
consequential damages or for any costs other than those incurred by HEAT-N-GLO to repair or replace the
defective component.
This Limited Warranty is the exclusive remedy available to you. If HEAT-N-GLO cannot effectively resolve a
warranty problem in an expedient and cost-effective manner, it can discharge its entire warranty liability by
refunding the price of the product to you.
Products made by other manufacturers, whether sold with the fireplace or added thereafter, are NOT covered by
this Limited Warranty. The use of other unauthorized components will make this warranty null and void. This
Limited Warranty will also be void if the appliance is not installed by a qualified installer in accordance with the
Installers Guide. Furthermore, the Limited Warranty will be void if the fireplace is not operated, at all times,
according to the Owners Guide furnished with the fireplace. Any service work
must be performed by authorized
service representatives.
EXCEPT TO THE EXTENT PROVIDED BY LAW, NO OTHER EXPRESS OR IMPLIED WARRANTIES,
FAILURE TO FOLLOW these installation instructions may result in a possible fire
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL
APPLY TO THE FIREPLACE PRODUCT. In States that do not allow limitations on how long an implied warranty
lasts, or do not allow exclusion of indirect damages, those limitations or exclusions may not apply to you. You may
also have additional rights not covered in this Limited Warranty.
HEAT-N-GLO reserves the right to make changes at any time, without notice, in design, material, specifications
and prices. It also reserves the right to discontinue styles and products.
hazard and will void the warranty.
Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the
Owners Guide.
DO NOT USE this appliance if any part has been under water. Immediately CALL a
qualified service technician to inspect the unit and to replace any part of the control
system and any gas control which has been underwater.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
Installation and repair should be PERFORMED by a qualified service person. The
appliance and venting system should be INSPECTED before initial use and at least
annually by a professional service person. More frequent cleaning may be required due
to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the units
control compartment, burners, and circulating air passageways BE KEPT CLEAN to
provide for adequate combustion and ventilation air.
Always KEEP the appliance clear and free from combustible materials, gasoline, and
other flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the
appliance CLEAR of all obstacles and materials for sevicing and proper operations.
Due to the high temperature, the appliance should be LOCATED out of traffic areas and
away from furniture and draperies. Clothing or flammable material SHOULD NOT BEPLACED on or near the appliance.
Children and adults should be ALERTED to the hazards of high surface temperature and
should STAY AWAY to avoid burns or clothing ignition. Young children should be
CAREFULLY SUPERVISED when they are in the same room as the appliance.
These units MUST use one of the vent systems described in the Installing the Fireplace
section of the Installers Guide. NO OTHER vent systems or components MAY BE USED.
This gas fireplace and vent assembly MUST be vented directly to the outside and MUSTNEVER be attached to a chimney serving a separate solid fuel burning appliance. Each
gas appliance MUST USE a separate vent system. Common vent systems are
PROHIBITED.
INSPECT the external vent cap on a regular basis to make sure that no debris is
interfering with the air flow.
The glass door assembly MUST be in place and sealed, and the trim door assembly
MUST be in place on the fireplace before the unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass door removed, cracked, or broken.
Replacement of the glass door should be performed by a licensed or qualified service
person. DO NOT strike or slam the glass door.
The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by
the gas fireplace manufacturer. NO SUBSTITUTE material may be used.
DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to
clean the glass door when it is hot.
Turn off the gas before servicing this appliance. It is recommended that a qualified
service technician perform an appliance check-up at the beginning of each heating
season.
Any safety screen or guard removed for servicing must be replaced before operating
this appliance.
i
Safety and Warning Information ...................... i
Section 1: Approvals and Codes ..................... 1
Approval Listings and Codes................................ 1
The fireplace installation must conform to local codes. Before installing the
fireplace, consult the local building code agency to ensure that you are in
compliance with all applicable codes, including permits and inspections.
Appliance Certification
The Heat-N-Glo fireplace models discussed in this
Installers Guide have been tested to certification
standards and listed by the applicable laboratories.
CERTIFICATION
In the absence of local codes, the fireplace installation must conform to the
National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGAB149 Installation Codes (in Canada). The appliance must be electrically
grounded in accordance with local codes or, in the absence of local codes with
the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the
CSA C22.1Canadian Electric Code (in Canada).
These models may be installed in a bedroom or bed-sitting room in the U.S.A.
and Canada.
High Altitude Installations
A.G.A./CGA Design Certified and U.L. Listed gas fireplaces are tested and
approved for elevations from 0 to 2,000 feet in the U.S.A. and from 0 to 4,500
feet in Canada.
When installing this fireplace at an elevation above 2,000 feet (in the United
States), it may be necessary to decrease the input rating by changing the
existing burner orifice to a smaller size. Input should be reduced four percent
(4%) for each 1,000 feet above sea level, unless the heating value of the gas has
been reduced, in which case this general rule will not apply. To identify the proper
orifice size, check with the local gas utility.
When installing this fireplace at an elevation between 2,000 and 4,500 feet (in
Canada), the input rating must be reduced by ten percent (10%).
When installing this fireplace at an elevation above 4,500 feet (in Canada), check
with local authorities.
Consult your local gas utility for assistance in determining the proper orifice for
your location.
1
Introducing the
Heat-N-Glo
Gas Fireplaces
Pre-installation
Preparation
Heat-N-Glo direct vent gas fireplaces are designed to
operate with all combustion air siphoned from outside
of the building and all exhaust gases expelled to the
outside.
The information contained in this Installers Guide,
unless noted otherwise, applies to all models and gas
control systems.
Gas fireplace diagrams, including the dimensions, are
shown in this section.
This gas fireplace and its components are tested and
safe when installed in accordance with this InstallersGuide. Report to your dealer any parts damaged in
shipment, particularly the condition of the glass. Do
not install any unit with damaged, incomplete, or
substitute parts.
The vent system components and trim doors are
shipped in separate packages. The gas logs are
factory installed (Model 6000GDVFL) and are
packaged separately and must be field installed
(Model 6000XLS). Read all of the instructions
before starting the installation. Follow these
instructions carefully during the installation to
ensure maximum safety and benefit. Failure to
follow these instructions will void the owners
warranty and may present a fire hazard.
2
Getting
Started
The Heat-N-Glo Fireplace Products, Inc. Warranty will
be voided by, and Heat-N-Glo Fireplace Products, Inc.
disclaims any responsibility for, the following actions:
Installation of any damaged fireplace or vent system
component.
Modification of the fireplace or direct vent system.
Installation other than as instructed by Heat-N-Glo
Fireplace Products, Inc.
Improper positioning of the gas logs or the glass
door.
Installation and/or use of any component part not
manufactured and approved by Heat-N-Glo Fireplace Products, Inc., not withstanding any independent testing laboratory or other party approval of
such component part or accessory.
ANY SUCH ACTION MAY POSSIBLY CAUSE A
FIRE HAZARD.
2
When planning a fireplace installation, its necessary to determine:
Where the unit is to be installed.
The vent system configuration to be used.
Gas supply piping.
Electrical wiring.
Framing and finishing details.
Whether optional accessoriesdevices such as a fan, wall switch, or remote
controlare desired.
If the fireplace is to be installed on carpeting or tile, or on any combustible
material other than wood flooring, the fireplace should be installed on a metal or
wood panel that extends the full width and depth of the fireplace.
3
Figure 1. Diagram of the6000 Series
Step 1
Locating the
Fireplace
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
3
Installing the
Fireplace
Figure 2. Fireplace Dimensions, Locations, and
Space Requirements
Clearance Requirements
The top, back, and sides of the fireplace are defined
by stand-offs.
For minimum clearances, see the direct vent
termination clearance diagrams on pages 19 and 21 in
this section.
Step 2
Framing the
Fireplace
CAUTION
The framing
headers may rest
on the fireplace
stand-offs.
Fireplace framing can be built before or after the
fireplace is set in place. Framing should be positioned
to accommodate wall coverings and fireplace facing
material. The diagram below shows framing reference
dimensions.
MEASURE FIREPLACE DIMENSIONS, AND
VERIFY FRAMING METHODS AND WALL
COVERING DETAILS, BEFORE FRAMING
CONSTRUCTION BEGINS.
B
C
A
Framing should be
constructed of 2 X 4
lumber or heavier.
ModelABCD
6000 Models4 238-1/42226-1/4
NOTE: DIMENSIONS SHOWN IN INCHES
Figure 3. Framing Dimensions
5
Step 3
Installing the
Vent System
A. Vent System Approvals
These appliances are approved to use D-series direct
vent pipe components and terminations. Approved
vent system components are labeled for identification.
NO OTHER VENTING SYSTEMS OR
COMPONENTS MAY BE USED. Detailed
installation instructions are included with each vent
termination kit and should be used in conjunction with
this Installers Guide. The drawing below shows vent
system components and terminations.
Identifying Vent Components
The vent systems installed on this gas fireplace may
include one, two, or three 90°
relationships of vertical rise to horizontal run in vent
configurations using 90° elbows MUST BE strictly
adhered to. The rise to run relationships are shown in
the venting drawings and tables. Refer to the
diagrams on the next several pages.
elbow assemblies. The
Vent system
termination kits
Figure 4. Vent Components and Terminations
Vent system components
6
6-5/32"
65/32
(156 mm)
7-3/8" 5-7/8"
57/873/8
(187 mm) (149 mm)
DV-90D
8-5/8"
85/8
(220 mm)
11-15/16"
1115/16
(303 mm)
DV-48D
8-1/2"
8/12
(216 mm)
47-3/4"
47 3/4
(1.2 m)
11-5/8"
115/8
(295 mm)
11-1/16"
111/16
(281 mm)
DV-36D
6-7/16"
67/16
(164 mm)
6-1/2"
61/2
(165 mm)
35-3/4"
35 3/4
(908 mm)
DV-45D
8-5/8"
85/8
(220 mm)
8-1/2"
81/2
(216 mm)
5-1/16"
51/16
(129 mm)
DV-12D
11-3/4"
11 3/4
(298 mm)
NOTE:PIPES OVERLAP 1 3/8 INCHES (34.93 mm) AT EACH JOINT.
NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93 mm) AT EACH JOINT.
DV-09D
8-3/4"
8 3/4
(222 mm)
Figure 5. D-Series Direct Vent Component Specifications
(5-inch inner pipe/8 5/8-inch outer pipe)
DV-06D
5-3/4"
5 3/4
(146 mm)
7
HORIZONTAL VENTING
Kit No.Max. Run
DVK-01D
DVK-01TRD24" (610 mm)
H
Figure 6. Corner Installation
Models 6000XLS, and 6000GDVFL are tested and
approved to use 45° elbows in corner installations.
However, 90° elbows will result in better performance.
8
VENTING WITH ONE (1) 90° ELBOW
1´ MIN. (305 mm)2´ MAX. (610 mm)
2´ MIN. (610 mm)4´ MAX. (1.22 m)
3´ MIN. (914 mm)6´ MAX. (1.86 m)
4´ MIN. (1.22 m)8´ MAX. (2.48 m)
40´ MAX. (12.4 m)8´ MAX. (2.48 m)
Figure 7. Venting with One 90° Elbow
9