Heat & Glo LifeStyle 6000 DVTFL, 8000 DVTFL, 6000 ARCH, SL-42 DVT, 6000 XLT User Manual

Heat-N-Glo Fireplace
Models:
8000 DVTFL 6000 DVTFL 6000 XLT 6000 ARCH SL-42 DVT
WARNING
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY , OR LOSS OF LIFE.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
Installers Guide
U.S. Patents 4,793,322; 4,875,464; 5,000,162 and Patents Pending Canadian Patent 1,297,746
Underwriters Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SER VICE OR MAINTENANCE CAN CAUSE INJUR Y OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENGY, OR THE GAS SUPPLIER.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by a qualified installer, service agency , or the gas supplier .
Printed in U.S.A. Copyright 1997,
Heat-N-Glo Fireplace Products, Inc. 6665 West Highway 13, Savage, MN 55378
1.This appliance may be installed in an
aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.
2. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Please contact your Heat-N-Glo Fireplace dealer for any questions or concerns. For the number of your nearest Heat-N-Glo dealer, please call 612-890-8367.
484-980-B 7/97
SAFETY AND WARNING INFORMATION
LIMITED 10 YEAR WARRANTY
HEAT-N-GLO GAS FIREPLACE PRODUCTS
In order to presumptively establish the dates to which your HEAT-N-GLO Limited 10 Year Warranty runs, you
must mail the completed warranty card to HEAT-N-GLO FIREPLACE PRODUCTS, INC., 6665 West
Highway 13, Savage, MN 55378, within 60 days of the date of fireplace installation. If you fail to do so, you
may be required to prove the date of installation before warranty work can be performed.
The warranty exclusions and limitations of liability are effective upon installation of the fireplace. Subject to the conditions set forth herein, HEAT-N-GLO FIREPLACE PRODUCTS, INC. ("HEAT-N-GLO") extends the following warranty with respect to HEAT-N-GLO Gas Fireplace Products. If HEAT-N-GLO is reasonably satisfied that any part or portion of the fireplace covered by this Limited Warranty is defective in material or workmanship under normal use and service as described in the Owners Guide, HEAT-N-GLO will take the following actions:
1.If the defect is reported during the first year from the date of installation (stainless steel burners and fiber logs are covered for 3 years), HEAT-N-GLO will replace or repair the defective components at its sole expense. The decision whether to replace a component shall be made at HEAT-N-GLO's sole discretion. This Limited Warranty does
not cover components broken during shipping, misuse or careless handling. HEAT-N-GLO
READ and UNDERSTAND all instructions carefully before starting the installation.
shall be not responsible for any indirect, incidental, or consequential damages or for any costs other than those incurred by HEAT-N-GLO to repair or replace the defective component. If components (including venting) other than factory approved components are used, all warranty and liability on the fireplace is voided. Defects
reported after the first year will not be covered by warranty unless they fall within the purview of paragraph 2 or 3 below.
2.If the following defects are reported during the second year after the date of installation, HEAT-N-GLO will supply replacement parts at the current wholesale price: defective electrical or manual components, optional components or accessories, and glass panels (not including glass panels broken during misuse or careless handling). HEAT-N-GLO shall not be responsible for any labor, transportation or other costs. Furthermore, HEAT-N-GLO shall not be liable for any indirect, incidental or consequential damages.
3.HEAT-N-GLO will replace or repair a defective firebox or heat exchanger, at any time during the 10 years from the date of installation. The decision whether to replace the defective component shall be made at HEAT-N-GLO's sole discretion. HEAT-N-GLO shall not be responsible for any indirect, incidental or consequential damages or for any costs other than those incurred by HEAT-N-GLO to repair or replace the defective component. This Limited Warranty is the exclusive remedy available to you. If HEAT-N-GLO cannot effectively resolve a warranty problem in an expedient and cost-effective manner, it can discharge its entire warranty liability by refunding the price of the product to you. Products made by other manufacturers, whether sold with the fireplace or added thereafter, are NOT covered by this Limited Warranty. The use of other unauthorized components will make this warranty null and void. This Limited Warranty will also be void if the appliance is not installed by a qualified installer in accordance with the Installers Guide. Furthermore, the Limited Warranty will be void if the fireplace is not operated, at all times, according to the Owners Guide furnished with the fireplace. Any service work
must be performed by authorized service representatives. EXCEPT TO THE EXTENT PROVIDED BY LAW, NO OTHER EXPRESS OR IMPLIED WARRANTIES,
FAILURE TO FOLLOW these installation instructions may result in a possible fire
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, SHALL APPLY TO THE FIREPLACE PRODUCT. In States that do not allow limitations on how long an implied warranty lasts, or do not allow exclusion of indirect damages, those limitations or exclusions may not apply to you. You may also have additional rights not covered in this Limited Warranty. HEAT-N-GLO reserves the right to make changes at any time, without notice, in design, material, specifications and prices. It also reserves the right to discontinue styles and products.
hazard and will void the warranty.
Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide.
DO NOT USE this appliance if any part has been under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been underwater.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
Installation and repair should be PERFORMED by a qualified service person. The appliance and venting system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the units control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.
Always KEEP the appliance clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for sevicing and proper operations.
Due to the high temperature, the appliance should be LOCATED out of traffic areas and away from furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.
Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.
These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide. NO OTHER vent systems or components MAY BE USED.
This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are
PROHIBITED.
INSPECT the external vent cap on a regular basis to make sure that no debris is
interfering with the air flow.
The glass door assembly MUST be in place and sealed, and the trim door assembly
MUST be in place on the fireplace before the unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass door removed, cracked, or broken.
Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.
The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.
DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.
Turn off the gas before servicing this appliance. It is recommended that a qualified service technician perform an appliance check-up at the beginning of each heating season.
Any safety screen or guard removed for servicing must be replaced before operating this appliance.
i
Safety and Warning Information................... i
Section 1: Approvals and Codes................... 1
Approval Listings and Codes ............................ 1
Appliance Certification .................................. 1
Installation Codes .......................................... 1
High Altitude Installations ............................ 1
Section 2: Getting Started............................. 2
Introducing the Heat-N-Glo Gas Fireplaces ...... 2
Pre-installation Preparation ............................... 2
Section 3: Installing the Fireplace ................ 6
Step 1 Locating the Fireplace .......................... 6
Step 2 Framing the Fireplace .......................... 7
Step 3 Installing the Vent System.................... 8
A . Vent System Approvals............................. 8
B. Installing Vent Components .................... 17
C. Vent Termination ..................................... 23
Step 4 Positioning, Leveling, and
Securing the Fireplace........................ 2 8
Step 5 The Gas Control Systems ................... 2 8
Step 6 The Gas Supply Line.......................... 29
Step 7 Gas Pressure Requirements................ 3 0
Step 8 Wiring the Fireplace ........................... 31
Step 9 Finishing ............................................ 33
Step 10 Installing Trim, Logs, and
Ember Material .................................. 34
Installing the Trim ........................................ 34
Positioning the Logs .................................... 35
Placing the Ember Material.......................... 35
Step 1 1 Before Lighting the Fireplace ............ 37
Step 12 Lighting the Fireplace ....................... 37
After the Installation ........................................ 37

T able of Contents

Section 4: Maintenance and Servicing ....... 3 8
Section 5: Replacement Parts
and Accessories .......................... 4 0
Replacement Parts ........................................... 4 0
Accessories ...................................................... 43
ii
1
Approvals and Codes
Approval Listings and Codes
MODEL LABORA TOR Y TYPE STANDARD
8000DVTFL Underwriters Direct Vent ANSI Z21.50•CGA2.22
Laboratories Decorative
6000DVTFL Underwriters Direct Vent ANSI Z21.50•CGA2.22
Laboratories Decorative
6000ARCH Underwriters Direct Vent ANSI Z21.50•CGA2.22
Laboratories Decorative
6000XL T Underwriters Direct Vent
Laboratories Decorative ANSI
SL-42DVT Underwriters Direct Vent ANSI Z21.50•CGA2.22
Laboratories Decorative
Installation Codes
Appliance Certification
The Heat-N-Glo fireplace models discussed in this
Installers Guide
standards and listed by the applicable laboratories.
Wall Furnace Z21.44/IR#41/CANI-2.19
have been tested to certification
CERTIFICA TION
Z21.50•CGA2.22
The fireplace installation must conform to local codes. Before installing the fireplace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections.
In the absence of local codes, the fireplace installation must conform to the National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA­B149 Installation Codes (in Canada). The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes with the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the CSA C22.1Canadian Electric Code (in Canada).
These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.
High Altitude Installations
U.L. Listed gas fireplaces are tested and approved for elevations from 0 to 2,000 feet in the U. S. A. and from 0 to 4,500 feet in Canada.
When installing this fireplace at an elevation above 2,000 feet (in the United States), it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input should be reduced four percent (4%) for each 1,000 feet above sea level, unless the heating value of the gas has been reduced, in which case this general rule will not apply . To identify the proper orifice size, check with the local gas utility .
When installing this fireplace at an elevation between 2,000 and 4,500 feet (in Canada), the input rating must be reduced by ten percent (10%).
When installing this fireplace at an elevation above 4,500 feet (in Canada), check with local authorities.
Consult your local gas utility for assistance in determining the proper orifice for
1
your location.
Introducing the Heat-N-Glo Gas Fireplaces
Heat-N-Glo direct vent gas fireplaces are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Pre-installation Preparation
The information contained in this unless noted otherwise, applies to all models and gas control systems.
Gas fireplace diagrams, including the dimensions, are shown in this section.
This gas fireplace and its components are tested and safe when installed in accordance with this
Guide
. Report to your dealer any parts damaged in
shipment, particularly the condition of the glass. Do
not install any unit with damaged, incomplete, or substitute parts.
The vent system components and trim doors are shipped in separate packages. The gas logs are factory installed (Model 8000DVTFL) and are packaged separately and must be field installed (Models 6000DVTFL, 6000ARCH, 6000XL T , SL­42DVT). Read all of the instructions before
starting the installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. Failure to follow these instructions will void the owner’s warranty and may present a fire hazard.
Installers Guide
,
Installers
2
Getting Started
The Heat-N-Glo Fireplace Products, Inc. Warranty will be voided by , and Heat-N-Glo Fireplace Products, Inc. disclaims any responsibility for, the following actions:
• Installation of any damaged fireplace or vent system component.
• Modification of the fireplace or direct vent system.
• Installation other than as instructed by Heat-N-Glo Fireplace Products, Inc.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not manufactured and approved by Heat-N-Glo Fire­place Products, Inc., not withstanding any indepen­dent testing laboratory or other party approval of such component part or accessory.
ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD.
2
When planning a fireplace installation, it’s necessary to determine:
Where the unit is to be installed.
The vent system configuration to be used.
Gas supply piping.
Electrical wiring.
Framing and finishing details.
Whether optional accessories—devices such as a fan, wall switch, or remote
control—are desired.
If the fireplace is to be installed on carpeting or tile, or on any combustible material other than wood flooring, the fireplace should be installed on a metal or wood panel that extends the full width and depth of the fireplace.
3
Figure 1. Diagram of 8000DVTFL
Figure 2. Diagram of 6000DVTFL, 6000XLT and 6000ARCH
4
Figure 3. Diagram of SL-42DVT
5
Step 1 Locating the Fireplace
The diagram below shows space and clearance requirements for locating a fireplace within a room.
3
Installing the Fireplace
Figure 4. Fireplace Dimensions, Locations, and
Space Requirements
Clearance Requirements
The top, back, and sides of the fireplace are defined by stand-offs.
Minimum Clearances from the Fireplace to
Combustible Materials
Glass Back of Sides of Top of
Front Floor Fireplace Fireplace Fireplace Ceiling
36 inches 0 1/2 inch 1/2 inch 3-1/2 inches 31 inches (914 mm) (13 mm) (13 mm) (89 mm) (787 mm)
The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25 mm).
For 6000 Series Models, the back of the fireplace may be recessed 21-1/2 inches (546 mm) into combustible construction.
For the 8000 DVTFL, the back of the fireplace may be recessed 24-7/8 inches (641 mm) into combustible construction.
For the SL-42DVT, the back of the fireplace may be recessed 16 1/2-inches (419mm) into combustible construction.
6
Minimum Clearances from the V ent Pipe to
Combustible Materials
For Vertical
For Horizontal Sections Sections At Wall Firestops
Top Bottom Sides Top Bottom Sides
3 inches 1 inch 1 inch 1 inch 2-1/2 inches 1/2 inch 1 inch (75 mm) (25 mm) (25 mm) (25 mm) (63.7 mm) (13 mm) (25 mm)
For minimum clearances, see the direct vent termination clearance diagrams on pages 25 and 27 in this section.
Step 2 Framing the Fireplace
CAUTION
The framing headers may rest on the fireplace stand-offs.
Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall coverings and fireplace facing material. The diagram below shows framing reference dimensions.
MEASURE FIREPLACE DIMENSIONS, AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS, BEFORE FRAMING CONSTRUCTION BEGINS.
B
C
A
Framing should be constructed of 2 X 4 lumber or heavier.
Model A B C D
8000DVTFL 49 42-3/8 25-3/8 47 6000DVTFL & 6000XLT 42 38-1/4 22 43-1/4 6000ARCH 42* 42-3/8 22 53-5/8
48-1/4**
SL-42DVT 49 42-7/8 17 45-3/4
NOTE: DIMENSIONS SHOWN IN INCHES
*SURROUND IN FRONT OF FINISHED WALL
**SURROUND FLUSH WITH FINISHED WALL
Figure 5. Framing Dimensions
7
Step 3
TERMINATION KITS
SLK-01D
SLK-TVCD SLK-991D
SLK-TVCD SLK-991D
SLK-01TRD
Installing the V ent System
Vent system termination kits
A. Vent System Approvals
Models 8000DVTFL, 6000DVTFL, 6000XL T , and 6000ARCH are approved to use D-series direct vent pipe components and terminations. Model SL­42DVT is approved to us SL-D-series components and terminations. Approved vent system components are labeled for identification. NO OTHER VENTING SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this below shows vent system components and terminations.
Identifying Vent Components
The vent systems installed on this gas fireplace may include one, two, or three 90° elbow assemblies. The relationships of vertical rise to horizontal run in vent configurations using 90° elbows MUST BE strictly adhered to. The rise to run relationships are shown in the venting drawings and tables. Refer to the diagrams on the next several pages.
VERTICAL
VERTICAL
TERMINATION
TERMINATION
Installers Guide
COMPONENT IDENTIFICATION
Vent system components
. The drawing
STORM COLLAR
D-SERIES
TERMINATION KITS
DVK-01D
DVK-01D
DVK-02D
DVK-02D
DVK-01SD
DVK-01SD
DVK-02SD
DVK-02SD
DVK-TVCD
DVK-01TRD
DVK-01TRD
DVK-02TRD
DVK-02TRD
HORIZONTAL
HORIZONTAL
TERMINATION
TERMINATION
WALL FIRESTOP
90 DEGREE
90 DEGREE
ELBOW
ELBOW
SL-D-SERIES
Figure 6. Vent Components and Terminations
CEILING
CEILING
FIRESTOP
FIRESTOP
ROOF FLASHING
HORIZONTAL PIPE
HORIZONTAL PIPE
SUPPORT
SUPPORT
PIPE LENGTH
WALL BRACKET
8
6-5/32"
65/32
(156 mm)
7-3/8" 5-7/8"
57/873/8
(187 mm) (149 mm)
DV-90D
8-5/8"
85/8
(220 mm) 11-15/16"
11 15/16
(303 mm)
DV-48D
8-1/2"
8/12
(216 mm)
47-3/4"
47 3/4
(1.2 m)
11-5/8"
11 5/8
(295 mm)
11-1/16"
11 1/16
(281 mm)
DV-36D
6-7/16"
67/16
(164 mm)
6-1/2"
61/2
(165 mm)
35-3/4"
35 3/4
(908 mm)
DV-45D
8-5/8"
85/8
(220 mm)
8-1/2"
81/2
(216 mm)
5-1/16"
51/16
(129 mm)
DV-12D
11-3/4"
11 3/4
(298 mm)
NOTE: PIPES OVERLAP 1 3/8 INCHES (34.93 mm) AT EACH JOINT.
NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93 mm) A T EACH JOINT .
DV-09D
8-3/4"
8 3/4
(222 mm)
Figure 7. D-Series Direct V ent Component Specifications (5-inch inner pipe/8 5/8-inch outer pipe)
DV-06D
5-3/4"
5 3/4
(146 mm)
9
Figure 8. SL-D-Series Direct Vent Component Specifications (4-inch inner pipe/6 5/8-inch outer pipe)
10
VERTICAL VENTING
V (FT.)
40' MAX. (12.4 M)
NOTE: MODEL 6000 ARCH
A 12-inch length of straight vent pipe MUST be the first vent component attached to the unit.
CAP
V
11
Figure 9. Vertical Venting