WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Installers Guide
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERSGUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1. This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Printed in U.S.A. Copyright 2000,
Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Please contact your Heat-N-Glo dealer with any
questions or concerns. For the number of your nearest
Heat-N-Glo dealer, please call 952-985-6000.
530-985B 11/00
1
SAFETY AND WARNING INFORMATION
READ and UNDERSTAND all instructions carefully
!
before starting the installation. FAILURE TO
FOLLOW these installation instructions may result
in a possible fire hazard and will void the warranty.
Prior to the first firing of the fireplace, READ the
!
Using Your Fireplace section of the Owners Guide.
DO NOT USE this appliance if any part has been
!
under water. Immediately CALL a qualified service
technician to inspect the unit and to replace any part
of the control system and any gas control which has
been under water.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
!
Installation and repair should be PERFORMED by a
qualified service person. The appliance and venting
!
system should be INSPECTED before initial use
and at least annually by a professional service
person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding
material, etc. It is IMPERATIVE that the units
control compartment, burners, and circulating air
passageways BE KEPT CLEAN to provide for
adequate combustion and ventilation air.
These units MUST use one of the vent systems
described in the Installing the Fireplace section of
!
the Installers Guide. NO OTHER vent systems or
components MAY BE USED.
This gas fireplace and vent assembly MUST be
!
vented directly to the outside and MUST NEVER be
attached to a chimney serving a separate solid fuel
burning appliance. Each gas appliance MUST USE
a separate vent system. Common vent systems are
PROHIBITED.
INSPECT the external vent cap on a regular basis to
!
make sure that no debris is interfering with the air
flow.
The glass door assembly MUST be in place and
!
sealed, and the trim door assembly MUST be in
place on the fireplace before the unit can be placed
into safe operation.
DO NOT OPERATE this appliance with the glass
!
door removed, cracked, or broken. Replacement of
the glass door should be performed by a licensed
or qualified service person. DO NOT strike or slam
the glass door.
Always KEEP the appliance clear and free from
!
combustible materials, gasoline, and other
flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and
!
ventilation air. Keep the front of the appliance
CLEAR of all obstacles and materials for servicing
and proper operations.
Due to the high temperature, the appliance should
be LOCATED out of traffic areas and away from
!
furniture and draperies. Clothing or flammable
material SHOULD NOT BE PLACED on or near the
appliance.
Children and adults should be ALERTED to the
!
hazards of high surface temperature and should
STAY AWAY to avoid burns or clothing ignition.
Young children should be CAREFULLY SUPERVISED
when they are in the same room as the appliance.
The glass door assembly SHALL ONLY be
!
replaced as a complete unit, as supplied by the gas
fireplace manufacturer. NO SUBSTITUTE material
may be used.
DO NOT USE abrasive cleaners on the glass door
!
assembly. DO NOT ATTEMPT to clean the glass
door when it is hot.
Turn off the gas before servicing this appliance. It is
recommended that a qualified service technician
!
perform an appliance check-up at the beginning of
each heating season.
Any safety screen or guard removed for servicing
!
must be replaced before operating this appliance.
2
TABLE OF CONTENTS
Safety and Warning Information ......................................................... 2
u
Service Parts Lists ................................................................................. 4
Section 1: Approvals and Codes ........................................................ 16
Approval Listings and Codes .................................................................. 16
Step 10Installing Trim, Logs, and Ember Material ............................. 50
Installing the Trim .................................................................. 50
Removing Grate Shipping Support ........................................... 50
u
Positioning the Logs ............................................................. 50
u
Placing the Ember Material ................................................... 50
Step 11Before Lighting the Fireplace................................................. 51
u
Step 12Lighting the Fireplace ............................................................ 51
After the Installation ............................................................................... 51
Section 4: Maintaining and Servicing Your Fireplace .................... 52
u = Contains updated information.
3
Service Parts
SL-550TR and SL-550TR-DSI (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces
7
11
6
10
9
12
8
13
14
1
5
4
3
2
15
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
4
SL-550TR and SL-550TR-DSI (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure
n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents.
Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITE M /
PIÈCE
STANDING PILOT AND DSI IGNITION COMMON PARTS
/ UNE VEILLEUSE ET ALLUMAGE DSI PIÉCES COMMUNES
SERIAL # / N° DE
SÉRIE
PART NUMBER
/ N° DE PIÈCE
ON/OFF Rocker Switch / Interr upteur à bascule marche/arrêt060-511
Burner Tube / Tube de brûleur477-301A
1Burner Orifice NG (#44A) / Orifice de brûleur GN (#44A )041-800
1Burner Orifi ce LP (#54A) / Orifice de brûleur PL (#54A)061-801
2Burner NG, LP / B rûleur GN, PL530-131A
3Glass Door Assembly / Porte en verreGLA-550
4Log Grate / Grille de Bûche550-360A
5Base Refractory NG / Réfr a ctai r e Base G N
5Base Refractory LP / Réfr a ctaire Bas e PL
PRE 19658
POST 19658
PRE 1432
POST 1432
SRV550-337
SRV550-339
SRV550-337
SRV550-339
6Hood / HotteSRV550-175
7Log Set Assembly / Module de Jeu de B ûchesLOGS-550S
8Log 1 / Bûche 1SRV530-701
9Log 2 / Bûche 2SRV530-704
10Log 3 / Bûche 3SRV530-702
11Log 4 / Bûche 4SRV530-703
12Log 5 / B ûc he 5SRV530-705
13Log 6 / B ûc he 6SRV569-707
STANDING PILOT IGNITION ONLY / D’ALLUMAGE PAR VEIL LEUSE SEULEMENT
14Junction Box / Boîtier de raccordement100-250A
Piezo Ignitor / Allumage Piézo418-513
Valve N G / Va lve G N060-522
Valve LP / Valve P L060-521
Pilot Assembly NG / Module de veilleuse GN485-510A
Pilot Assembly LP / Module de veilleuse PL485-511A
DSI IGNITION ONLY / ALLUMAGE DSI SEULEMENT
14Junction Box / Boîtier de raccordement100-254A
15Valve Assembly -DSI NG / Module de Valve-DSI GN550-007A
15Valve Assembly -DSI LP / Module de Valve-DSI PL550-008A
Fan Kit / Module de ventilateurGFK-160A
Extended Verti cal Baffle K it / Module de verticale étendu le déflecteurBAF-VERT
Wall Switch Kit, Off-white / Module d'interrupteur mural, Blanc CasséWSK-21
Wall Switch Kit, White / Module d'interrupteur mural, BlancWSK-21-W
Conversion Kit NG (Standing Pilot only)
/ Module de conversion GN (A llumage une veilleuse seulement)
Conversion Kit LP (Standing Pilot only)
/ Module de conversion PL (Allumage une vei lleuse seulement)
NGK-55TR
LPK-55TR
5
Service Parts
SL-550TRS-B (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces
3
2
4
6
5
15
11
7
8
10
9
14
13
12
1
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
6
SL-550TRS-B (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors
d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
STANDING PILOT IGNITION / D’ALLUMAGE PAR VEILLEUSE
Piezo Ignitor / Allumage Piézo418-513
Burner Tube / Tube de brûleur477-301A
1Burner Orifice NG (#38A ) / Orifice de brûleur GN (#38A )057-800
1Burner Orifice LP (#52A) / Orifice de brûleur PL (#52A)057-801
2Bur ne r NG / Brûleur GN547-231A
2Burner LP / Brûleur PL547-233A
3Glass Door Assembly / Porte en verreGLA-550S
4Log Grate / Grille de Bûche550-360A
5B ase Refractory NG / Réf rac taire Bas e N G
5B ase Refractory LP / Réf rac tai r e Bas e PL
6Hoo d / HotteSRV550-175
7Log S et Assembly / Module de Jeu de BûchesLOGS-550S
11Log 4 / Bûche 4SRV530-703
12Log 5 / B ûche 5SRV530-705
13Log 6 / B ûche 6SRV569-707
14
Va lve Ass e m bly NG / M o dule d e va lve G N
14
Valve Assembly LP / Module de valve PL
534-015A
534-016A
15Junction Box / Boîtier de raccordement100-250A
Valve NG / Va lve GN060-522
Valve L P / Va lve PL060-523
Pilot A ssembly NG / Module de veilleuse GN485-510A
Pilot A ssembly LP / Module de veilleuse PL485-511A
Pilot Orifice NG / Orifice de veilleuse GN446-505
Pilot Orifice LP / Orifice de veilleuse PL446-517
Fan Kit / Module de ventilateurGFK-160A
Extended Vertical B affle Kit / Module de verticale étendu le déflecteurBAF-VERT
Wall Switch Kit, Off-white / Module d'interrupteur mural, Blanc CasséWSK-21
Wall Switch Kit, White / Module d'interrupteur mural, B lancWSK-21-W
Conversion Kit NG / Module de conversion GN
Conversion Kit LP / Module de conversion PL
PRE 2172
POST 2172
PRE 1234
POST 1234
7
NGK-55TR
NGK-55TRS
LPK-55TR
LPK-55TRS
Service Parts
SL-750TR and SL-750TR-DSI (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
6
2
1
14
1
13
12
10
9
4
5
3
7
8
11
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
8
SL-750TR and SL-750TR-DSI (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure
n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents.
Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITE M /
PIÈCE
STANDING PILOT AND DSI IGNITION/
UNE VEILLEUSE ET ALLUMAGE DSI
ON/OFF Rocker Switch / Interrupteur à bascule marche/arrêt060-511
Burner Tube / Tube de brûleur477-301A
1Burner Orifice NG (#42A) / Ori fice de brûleur GN (#42A)060 -800
1Burner Orifice LP (#53A) / Ori fice de brûleur PL (#53A)060-801
2Bur ner N G / Br ûleur G N560-231A
2Bur ner LP / Br ûleur PL530-233A
3Glass Door Assembly / Porte en verreGLA-750
4Log Grate / Grille de Bûche530-360A
5Base Refractory NG / Ré fr a c tai r e Ba s e G N
5Base Refractory LP / Réfra c taire Ba s e PL
6Hood / HotteSRV530-175
7Log Set Assembly / Module de Jeu de BûchesLOGS-750
8Log 1 / Bûche 1S RV530-711
9Log 2 / Bûche 2S RV402-701
10Log 3 / Bûche 3S RV560-703
11Log 4 / Bûche 4SRV560-702
12Log 5 / Bûche 5SRV560-704
STANDING PILOT IGNITION ONLY / D’ALLUMAGE PAR VEILLEUSE SEULEMENT
Piezo Ignitor / Allumage Piézo418-513
13Junction B ox / Boîtier de raccordement100-250A
Va lve N G / Va lve G N060-522
Valve LP / Valve PL060-521
Pilot Assembly NG / Module de vei lleuse GN485-510A
Pilot Assembly LP / Module de veilleuse PL485-511A
Pilot Orifice NG / Orifice de ve illeuse GN446-505
Pilot Orifice LP / Orifice de veilleuse PL446-517
Thermocouple / Thermocouple446-511
Thermopile / Thermopile060-512
Pilot Tube / Tube de veilleuseSRV485-301
DSI IGN ITION ONLY / ALL UM AGE DSI S E UL EMENT
13Junction B ox / Boîtier de raccordement100-254A
14Valve Assembly -DSI NG / Module de Valve-DSI GN550-007A
14Valve Assembly -DSI LP / Module de Valve-DSI PL550-008A
DSI Valve NG / DSI Valve GN492-500
DSI Valve LP / D S I Valve PL492-501
Ignitor / A llumag e501-591
Module / Module501-592
ACCE S SOR IES / AC C ES S OIR ES
Fan Kit / Module de ventilateurGFK-160A
Exte nded Vertical B affle Kit / Module de verti cale étendu le déflecteurBAF-VE RT
Wall Switch Ki t, White / Module d'interrupteur mura l, BlancWSK-21-W
Conversion Kit NG (Standing Pilot only)
/ Module de conversio n GN (Allumage une veilleuse seulement)
Conversion Kits LP (Standing P ilot only)
/ Modules de conversio n PL (Allumage une veilleuse seulement)
SERIA L # / N° D E
SÉRIE
PRE 37686
POST 37686
PRE 2694
POST 2694
PART NUMBER
/ N° DE PIÈCE
SRV530-337
SRV530-339
SRV530-337
SRV530-339
NGK-7 5TR
LPK-75TR
9
Service Parts
SL-750TRS-B (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
6
2
3
1
7
13
8
9
10
11
5
4
12
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
10
SL-750TRS-B (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure
n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents.
Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITE M /
PIÈCE
STANDING PILOT IGNITION / ALLUMAGE UNE VEILLEUSE
SERIAL # / N° DE
SÉRIE
PART NUMBER
/ N° DE PIÈCE
Piezo Ignitor / Allumage Piézo418-513
Burner Tube / Tube de brûleur477-301A
1Burner Orifice NG (#36A ) / Orifice de brûleur GN (#36A)079-831
1Burner Orifice LP (#52A) / Orifice de brûleur PL (#52A)057-801
2Burner NG / Brûleur GN534-231A
2Burner LP / Brûleur PL534-233A
3Glass Door Assembly / Porte en verreGLA-750S
4Log Grate / Grille de Bûche530-360A
5Base Refractory NG / Réfracta ir e Ba se GN
5Base Refractory LP / Réfractair e Ba se P L
PRE 4241
POST 4241
PRE 1515
POST 1515
SRV530-337
SRV530-339
SRV530-337
SRV530-339
6Hoo d / HotteSRV530-175
7Log Set Assembly / Module de Jeu de BûchesLOGS -750
8Log 1 / Bûche 1SRV530-711
9Log 2 / Bûche 2SRV402-701
Valve NG / Valve GN060-522
Valve L P / Valve PL060-523
Pilot Assembly NG / Module de veilleuse GN485-510A
Pilot Assembly LP / Module de veilleuse PL485-511A
ACCESSORIES / ACC ESSOIRES
Fan Kit / Module de ventilateurGFK-160A
Extended Vertical B affle Kit / Module de verticale étendu le déflecteurBAF-VERT
Wall Switc h Kit, Off-white / Mo d ule d 'i nterrupte ur mural, Bla nc CasséWSK-21
Wall Switch Kit, Whi te / Module d'interrupteur mural, BlancWSK-21-W
Conversion Kit NG / Module de conversion GN
Conversion Kit LP / Module de conversion PL
PRE 2344
POST 2344
PRE 1288
POST 1288
11
NGK-75TR
NGK-75TRS
LPK-75TR
LPK-75TRS
Service Parts
SL-750TRFL (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
6
2
1
4
5
3
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
8
7
12
SL-750TRFL (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors
d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
STANDING PILOT IGNITION / ALLUMAGE UNE VEILLEUSE
SERIAL # /
N° DE SÉRI E
PART NUMBER
/ N° DE P IÈCE
ON/OFF Rocke r S wi tch / Interrupteur à bascule marche /arrêt060-511
Piezo Ignitor / Allumage P iézo418-513
Burner Tube / Tube de brûleur477-301A
1Burner Orifice NG (#42A) / Orifice de brûleur GN (#42A)060-800
1Burner Orifice LP (#53A) / Orifice de brûleur PL (#53A)060-801
2B ur ne r N G / Brûle ur G N560-231A
2Bur ne r L P / Brûleur PL530-233A
3Glass Door Assembly / Porte en verreGLA-750
4Log Grate / Grille de Bûche538-361A
5Base Refractory / Réfrac ta i r e Bas eSRV530-339
6Hood / HotteSRV530-175
7Log Set Assembly / Module de Jeu de BûchesLOGS-750ALT
8Junction Box / Boîtier de raccordement100-250A
Valve NG / Va lve GN060-520
Valve LP / Valve PL060-521
Pilot Assembly NG / Module de veilleuse GN485-510A
Pilot Assembly LP / Module de veilleuse PL485-511A
Pilot Orifice NG / Orifice de veilleuse GN446-505
Pilot Orifice LP / Orifice de veilleuse PL446-517
Thermocouple / Thermocouple446-511
Thermopile / Thermopile060-512
Pilot Tube / Tube de veilleuseSRV485-301
AC CE S SOR IES / ACCESS OIRE S
Fan Kit / Module de ventilateurGFK-160A
Extended Vertical Baffle Kit / Module de verticale étendu le déflecteurBA F-VERT
Wall Switch Kit, White / Module d'interrupteur mural, BlancWSK-21-W
Conversion K it NG / Module de conversion GNNGK-75TR
Conversion K it LP / Module de conversion PLLP K-75TR
13
Service Parts
SL-950TR and SL-950TR-DSI (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
4
6
5
3
13
10
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
14
2
15
1
12
7
8
9
11
14
SL-950TR and SL-950TR-DSI (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors
d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
STANDING PILOT AND DSI IGNITION/
UNE VEILLEUSE ET ALLUMAGE DSI
SERIAL # / N° DE
SÉRIE
PART NUMBER
/ N° DE PIÈCE
ON/OFF Rocker Switch / Interrupteur à bascule marche/arrêt060-511
Burner Tube / Tub e de brûle ur4 77-301A
1Burner Orifice NG (#36A) / Orifice de brûleur GN (#36A)079-831
1Burner Orifice LP (#51A) / Orifice de brûleur PL (#51A)079-803
2B ur ner N G / Brûle ur G N560-231A
2B ur ner LP / Br ûleur PL560-233A
3Glass Door Assembly / Po rte en verreGLA-950
4Log Grate / Grille de B ûche56 0-360A
5Base Refractory NG / Réfr ac t a ir e Base G N
5Base Refractory LP / Réfr ac t ai r e Bas e PL
PRE 4196
POST 4196
PRE 1119
POST 1119
SRV560-337
SRV560-339
SRV560-337
SRV560-339
6Hood / HotteSRV560-175
7Log S et Assembly / Module de Jeu de BûchesLOGS-950
8Log 1 / Bûche 1SRV530-711
9Log 2 / Bûche 2SRV402-701
STANDING PILOT IGNITION ONLY / D’ALLUMAGE PAR VEILLEUSE SEULEMENT
Piezo Ignitor / Allumage Piézo418 -513
14Junction Box / Boîtier de raccordement100-250A
Valve NG / Valve GN060-520
Valve LP / Valve PL06 0-521
Pilot Assembly NG / Module de veilleuse GN485-510A
Pilot Assembly L P / Module d e veilleuse PL485-511A
Pilot Orifice NG / Orifice de veilleuse GN446-505
Pilot Orifice LP / Orifice de veilleuse PL446-517
Fan Kit / Module de ventilateurGFK-160A
Extended Vertical Baffle K it / Module de verticale étendu le déflecteurBAF-VE RT
Wall Switch Ki t, Off-white / Module d'interrupte ur mural, B lanc CasséWSK -21
Wall Switch Ki t, White / Module d'interrup teur mural, BlancWSK -21-W
C onvers ion K it NG ( Sta nd ing Pilo t O nly)
/ Modules de conversion GN (allumage une veilleuse seulement)
Conversion K it LP (Standing P ilot Only)
/ Modules de conversion PL (allumage une veilleuse seulement)
NGK-95TR
LPK-95TR
15
1
Approvals and
Codes
Appliance Certification
The Heat-N-Glo fireplace models discussed in this Installers
Guide have been tested to certification standards and listed
by the applicable laboratories.
Certification
MODELS: SL-950TR, SL-750TR, SL-750TRFL,
SL-750TRS, SL-550TR, SL-550TRS
LABORATORY: Underwriters Laboratories
TYPE: Direct Vent Gas Fireplace Heater
STANDARD: ANSI Z21.88CSA2.33
NOTE: THESE MODELS ARE UL LISTED TO UL307B,
THE STANDARD FOR GAS-BURNING HEATING APPLIANCES FOR MANUFACTURED HOMES AND RECRE-
ATIONAL VEHICLES.
Installation Codes
The fireplace installation must conform to local codes. Before
installing the fireplace, consult the local building code
agency to ensure that you are in compliance with all
applicable codes, including permits and inspections.
High Altitude Installations
U.L. Listed gas fireplaces are tested and approved for
elevations from 0 to 2,000 feet in the U.S.A. and from 0 to
4,500 feet in Canada.
When installing this fireplace at an elevation above 2,000
feet (in the United States), it may be necessary to decrease
the input rating by changing the existing burner orifice to a
smaller size. Input should be reduced four percent (4%) for
each 1,000 feet above sea level, unless the heating value of
the gas has been reduced, in which case this general rule
will not apply. To identify the proper orifice size, check with
the local gas utility.
When installing this fireplace at an elevation between 2,000
and 4,500 feet (in Canada), the input rating must be reduced
by ten percent (10%).
When installing this fireplace at an elevation above 4,500
feet (in Canada), check with local authorities.
Consult your local gas utility for assistance in determining
the proper orifice for your location.
In the absence of local codes, the fireplace installation must
conform to the National Fuel Gas Code ANSI Z223.1 (in
the United States) or the CAN/CGA-B149 Installation Codes
(in Canada). The appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes with the National Electric Code ANSI/NFPA No. 70
(in the United States), or to the CSA C22.1 Canadian Electric
Code (in Canada).
These models may be installed in a bedroom or bed-sitting
room in the U.S.A. and Canada.
Heat-N-Glo Quality
Systems registered
by SGS ICS
16
Loading...
+ 36 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.