Heat & Glo SL-950TR, SL-750TR, SL-750TRS, SL-750TRFL, SL-550TR Installers Guide

...
Models:
SL-950TR SL-750TR SL-750TRS SL-750TRFL SL-550TR SL-550TRS
WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUS­ING PROPERTY DAMAGE, PER­SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam­mable vapors and liquids in the vicinity of this or any other appliance.
- What to do if you smell gas  Do not try to light any appliance.  Do not touch any electrical switch.  Do not use any phone in your building.  Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's instructions.
 If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
Installers Guide
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA­TION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAM­AGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFOR­MATION CONSULT A QUALIFIED IN­STALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.
1. This appliance may be installed in an af­termarket, permanently located, manufac­tured (mobile) home, where not prohibited by local codes.
2. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Printed in U.S.A. Copyright 2000, Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Please contact your Heat-N-Glo dealer with any questions or concerns. For the number of your nearest Heat-N-Glo dealer, please call 952-985-6000.
530-985B 11/00
1
SAFETY AND WARNING INFORMATION
READ and UNDERSTAND all instructions carefully
!
before starting the installation. FAILURE TO FOLLOW these installation instructions may result
in a possible fire hazard and will void the warranty.
Prior to the first firing of the fireplace, READ the
!
Using Your Fireplace section of the Owners Guide.
DO NOT USE this appliance if any part has been
!
under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.
THIS UNIT IS NOT FOR USE WITH SOLID FUEL.
!
Installation and repair should be PERFORMED by a qualified service person. The appliance and venting
!
system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the units control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.
These units MUST use one of the vent systems described in the Installing the Fireplace section of
!
the Installers Guide. NO OTHER vent systems or components MAY BE USED.
This gas fireplace and vent assembly MUST be
!
vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are
PROHIBITED.
INSPECT the external vent cap on a regular basis to
!
make sure that no debris is interfering with the air flow.
The glass door assembly MUST be in place and
!
sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation.
DO NOT OPERATE this appliance with the glass
!
door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.
Always KEEP the appliance clear and free from
!
combustible materials, gasoline, and other flammable vapors and liquids.
NEVER OBSTRUCT the flow of combustion and
!
ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations.
Due to the high temperature, the appliance should be LOCATED out of traffic areas and away from
!
furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.
Children and adults should be ALERTED to the
!
hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.
The glass door assembly SHALL ONLY be
!
replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.
DO NOT USE abrasive cleaners on the glass door
!
assembly. DO NOT ATTEMPT to clean the glass door when it is hot.
Turn off the gas before servicing this appliance. It is recommended that a qualified service technician
!
perform an appliance check-up at the beginning of each heating season.
Any safety screen or guard removed for servicing
!
must be replaced before operating this appliance.
2

TABLE OF CONTENTS

Safety and Warning Information ......................................................... 2
u
Service Parts Lists ................................................................................. 4
Section 1: Approvals and Codes ........................................................ 16
Approval Listings and Codes .................................................................. 16
u
Appliance Certification ........................................................................... 16
Installation Codes .................................................................................. 16
High Altitude Installations ...................................................................... 16
Section 2: Getting Started .................................................................. 17
Introducing the Heat-N-Glo Gas Fireplaces ............................................ 17
Pre-installation Preparation .................................................................... 17
Section 3: Installing the Fireplace..................................................... 21
u
Step 1 Locating the Fireplace ........................................................... 21
Step 2 Framing the Fireplace ........................................................... 21
u
Step 3 Installing the Vent System .................................................... 24
A. Vent System Approvals ................................................... 24
B. Installing Vent Components ............................................. 22
C. Vent Termination.............................................................. 42
Step 4 Positioning, Leveling, and
Securing the Fireplace .......................................................... 45
Step 5 The Gas Control Systems ..................................................... 45
Step 6 The Gas Supply Line............................................................. 46
Step 7 Gas Pressure Requirements ................................................. 46
Step 8 Wiring the Fireplace .............................................................. 47
Step 9 Finishing ............................................................................... 49
Step 10 Installing Trim, Logs, and Ember Material ............................. 50
Installing the Trim .................................................................. 50
Removing Grate Shipping Support ........................................... 50
u
Positioning the Logs ............................................................. 50
u
Placing the Ember Material ................................................... 50
Step 11 Before Lighting the Fireplace................................................. 51
u
Step 12 Lighting the Fireplace ............................................................ 51
After the Installation ............................................................................... 51
Section 4: Maintaining and Servicing Your Fireplace .................... 52
u = Contains updated information.
3
Service Parts
SL-550TR and SL-550TR-DSI (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces
7
11
6
10
9
12
8
13
14
1
5
4
3
2
15
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
4
SL-550TR and SL-550TR-DSI (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order­ing, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITE M /
PIÈCE
STANDING PILOT AND DSI IGNITION COMMON PARTS
/ UNE VEILLEUSE ET ALLUMAGE DSI PIÉCES COMMUNES
SERIAL # / N° DE
SÉRIE
PART NUMBER
/ N° DE PIÈCE
ON/OFF Rocker Switch / Interr upteur à bascule marche/arrêt 060-511 Burner Tube / Tube de brûleur 477-301A
1 Burner Orifice NG (#44A) / Orifice de brûleur GN (#44A ) 041-800
1 Burner Orifi ce LP (#54A) / Orifice de brûleur PL (#54A) 061-801 2 Burner NG, LP / B rûleur GN, PL 530-131A 3 Glass Door Assembly / Porte en verre GLA-550 4 Log Grate / Grille de Bûche 550-360A
5 Base Refractory NG / Réfr a ctai r e Base G N 5 Base Refractory LP / Réfr a ctaire Bas e PL
PRE 19658 POST 19658 PRE 1432 POST 1432
SRV550-337 SRV550-339 SRV550-337 SRV550-339
6 Hood / Hotte SRV550-175 7 Log Set Assembly / Module de Jeu de B ûches LOGS-550S 8 Log 1 / Bûche 1 SRV530-701 9 Log 2 / Bûche 2 SRV530-704
10 Log 3 / Bûche 3 SRV530-702
11 Log 4 / Bûche 4 SRV530-703 12 Log 5 / B ûc he 5 SRV530-705 13 Log 6 / B ûc he 6 SRV569-707
STANDING PILOT IGNITION ONLY / D’ALLUMAGE PAR VEIL LEUSE SEULEMENT
14 Junction Box / Boîtier de raccordement 100-250A
Piezo Ignitor / Allumage Piézo 418-513 Valve N G / Va lve G N 060-522 Valve LP / Valve P L 060-521 Pilot Assembly NG / Module de veilleuse GN 485-510A Pilot Assembly LP / Module de veilleuse PL 485-511A
DSI IGNITION ONLY / ALLUMAGE DSI SEULEMENT
14 Junction Box / Boîtier de raccordement 100-254A
15 Valve Assembly -DSI NG / Module de Valve-DSI GN 550-007A
15 Valve Assembly -DSI LP / Module de Valve-DSI PL 550-008A
DSI Valve NG / DSI Valve GN 492-500 DSI Valve LP / DSI Valve PL 492-501 Ignitor / Alluma ge 501-591 Module / Module 501-592
ACCESSORIES / ACCESSOIRES
Fan Kit / Module de ventilateur GFK-160A Extended Verti cal Baffle K it / Module de verticale étendu le déflecteur BAF-VERT Wall Switch Kit, Off-white / Module d'interrupteur mural, Blanc Cassé WSK-21 Wall Switch Kit, White / Module d'interrupteur mural, Blanc WSK-21-W
Conversion Kit NG (Standing Pilot only) / Module de conversion GN (A llumage une veilleuse seulement) Conversion Kit LP (Standing Pilot only) / Module de conversion PL (Allumage une vei lleuse seulement)
NGK-55TR LPK-55TR
5
Service Parts
SL-550TRS-B (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces
3
2
4
6
5
15
11
7
8
10
9
14
13
12
1
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
6
SL-550TRS-B (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
STANDING PILOT IGNITION / D’ALLUMAGE PAR VEILLEUSE
Piezo Ignitor / Allumage Piézo 418-513
Burner Tube / Tube de brûleur 477-301A 1 Burner Orifice NG (#38A ) / Orifice de brûleur GN (#38A ) 057-800 1 Burner Orifice LP (#52A) / Orifice de brûleur PL (#52A) 057-801
2 Bur ne r NG / Brûleur GN 547-231A 2 Burner LP / Brûleur PL 547-233A 3 Glass Door Assembly / Porte en verre GLA-550S 4 Log Grate / Grille de Bûche 550-360A
5 B ase Refractory NG / Réf rac taire Bas e N G 5 B ase Refractory LP / Réf rac tai r e Bas e PL
6 Hoo d / Hotte SRV550-175 7 Log S et Assembly / Module de Jeu de Bûches LOGS-550S
SERIAL # / N° DE
SÉRIE
PRE 3585 POST 3585 PRE 3235 POST 3235
PART NU M BE R
/ N° DE PIÈCE
SRV550-337 SRV550-339 SRV550-337 SRV550-339
8 Log 1 / Bûche 1 SRV530-701 9 Log 2 / Bûche 2 SRV530-704
10 Log 3 / Bûche 3 SRV530-702
11 Log 4 / Bûche 4 SRV530-703 12 Log 5 / B ûche 5 SRV530-705 13 Log 6 / B ûche 6 SRV569-707 14
Va lve Ass e m bly NG / M o dule d e va lve G N
14
Valve Assembly LP / Module de valve PL
534-015A 534-016A
15 Junction Box / Boîtier de raccordement 100-250A
Valve NG / Va lve GN 060-522 Valve L P / Va lve PL 060-523 Pilot A ssembly NG / Module de veilleuse GN 485-510A Pilot A ssembly LP / Module de veilleuse PL 485-511A Pilot Orifice NG / Orifice de veilleuse GN 446-505 Pilot Orifice LP / Orifice de veilleuse PL 446-517
Thermocouple / Thermocouple 446-511 Thermopile / Thermopile 060-512
ACCESSORIES / ACCESSOIRES
Fan Kit / Module de ventilateur GFK-160A Extended Vertical B affle Kit / Module de verticale étendu le déflecteur BAF-VERT
Wall Switch Kit, Off-white / Module d'interrupteur mural, Blanc Cassé WSK-21 Wall Switch Kit, White / Module d'interrupteur mural, B lanc WSK-21-W
Conversion Kit NG / Module de conversion GN Conversion Kit LP / Module de conversion PL
PRE 2172 POST 2172 PRE 1234 POST 1234
7
NGK-55TR NGK-55TRS LPK-55TR LPK-55TRS
Service Parts
SL-750TR and SL-750TR-DSI (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
6
2
1
14
1
13
12
10
9
4
5
3
7
8
11
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
8
SL-750TR and SL-750TR-DSI (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order­ing, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITE M /
PIÈCE
STANDING PILOT AND DSI IGNITION/
UNE VEILLEUSE ET ALLUMAGE DSI
ON/OFF Rocker Switch / Interrupteur à bascule marche/arrêt 060-511
Burner Tube / Tube de brûleur 477-301A 1 Burner Orifice NG (#42A) / Ori fice de brûleur GN (#42A) 060 -800 1 Burner Orifice LP (#53A) / Ori fice de brûleur PL (#53A) 060-801
2 Bur ner N G / Br ûleur G N 560-231A 2 Bur ner LP / Br ûleur PL 530-233A 3 Glass Door Assembly / Porte en verre GLA-750 4 Log Grate / Grille de Bûche 530-360A
5 Base Refractory NG / Ré fr a c tai r e Ba s e G N 5 Base Refractory LP / Réfra c taire Ba s e PL
6 Hood / Hotte SRV530-175 7 Log Set Assembly / Module de Jeu de Bûches LOGS-750 8 Log 1 / Bûche 1 S RV530-711 9 Log 2 / Bûche 2 S RV402-701
10 Log 3 / Bûche 3 S RV560-703
11 Log 4 / Bûche 4 SRV560-702
12 Log 5 / Bûche 5 SRV560-704
STANDING PILOT IGNITION ONLY / D’ALLUMAGE PAR VEILLEUSE SEULEMENT
Piezo Ignitor / Allumage Piézo 418-513
13 Junction B ox / Boîtier de raccordement 100-250A
Va lve N G / Va lve G N 060-522
Valve LP / Valve PL 060-521
Pilot Assembly NG / Module de vei lleuse GN 485-510A
Pilot Assembly LP / Module de veilleuse PL 485-511A
Pilot Orifice NG / Orifice de ve illeuse GN 446-505
Pilot Orifice LP / Orifice de veilleuse PL 446-517
Thermocouple / Thermocouple 446-511
Thermopile / Thermopile 060-512
Pilot Tube / Tube de veilleuse SRV485-301
DSI IGN ITION ONLY / ALL UM AGE DSI S E UL EMENT
13 Junction B ox / Boîtier de raccordement 100-254A
14 Valve Assembly -DSI NG / Module de Valve-DSI GN 550-007A
14 Valve Assembly -DSI LP / Module de Valve-DSI PL 550-008A
DSI Valve NG / DSI Valve GN 492-500
DSI Valve LP / D S I Valve PL 492-501
Ignitor / A llumag e 501-591
Module / Module 501-592
ACCE S SOR IES / AC C ES S OIR ES
Fan Kit / Module de ventilateur GFK-160A
Exte nded Vertical B affle Kit / Module de verti cale étendu le déflecteur BAF-VE RT
Wall Switch Ki t, Off-white / Module d'interrupteur mural, Blanc Cassé WSK-21
Wall Switch Ki t, White / Module d'interrupteur mura l, Blanc WSK-21-W
Conversion Kit NG (Standing Pilot only)
/ Module de conversio n GN (Allumage une veilleuse seulement)
Conversion Kits LP (Standing P ilot only)
/ Modules de conversio n PL (Allumage une veilleuse seulement)
SERIA L # / N° D E
SÉRIE
PRE 37686 POST 37686
PRE 2694 POST 2694
PART NUMBER
/ N° DE PIÈCE
SRV530-337 SRV530-339
SRV530-337 SRV530-339
NGK-7 5TR LPK-75TR
9
Service Parts
SL-750TRS-B (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
6
2
3
1
7
13
8
9
10
11
5
4
12
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
10
SL-750TRS-B (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order­ing, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITE M /
PIÈCE
STANDING PILOT IGNITION / ALLUMAGE UNE VEILLEUSE
SERIAL # / N° DE
SÉRIE
PART NUMBER
/ N° DE PIÈCE
Piezo Ignitor / Allumage Piézo 418-513
Burner Tube / Tube de brûleur 477-301A 1 Burner Orifice NG (#36A ) / Orifice de brûleur GN (#36A) 079-831 1 Burner Orifice LP (#52A) / Orifice de brûleur PL (#52A) 057-801
2 Burner NG / Brûleur GN 534-231A 2 Burner LP / Brûleur PL 534-233A 3 Glass Door Assembly / Porte en verre GLA-750S 4 Log Grate / Grille de Bûche 530-360A 5 Base Refractory NG / Réfracta ir e Ba se GN
5 Base Refractory LP / Réfractair e Ba se P L
PRE 4241 POST 4241 PRE 1515 POST 1515
SRV530-337 SRV530-339 SRV530-337 SRV530-339
6 Hoo d / Hotte SRV530-175 7 Log Set Assembly / Module de Jeu de Bûches LOGS -750 8 Log 1 / Bûche 1 SRV530-711 9 Log 2 / Bûche 2 SRV402-701
10 Log 3 / Bûche 3 SRV560-703
11 Log 4 / Bûche 4 SRV560-702 12 Log 5 / Bûche 5 SRV560-704 13 Junction Box / Boîtier de raccordement 100-250A
Valve NG / Valve GN 060-522 Valve L P / Valve PL 060-523 Pilot Assembly NG / Module de veilleuse GN 485-510A Pilot Assembly LP / Module de veilleuse PL 485-511A
ACCESSORIES / ACC ESSOIRES
Fan Kit / Module de ventilateur GFK-160A Extended Vertical B affle Kit / Module de verticale étendu le déflecteur BAF-VERT Wall Switc h Kit, Off-white / Mo d ule d 'i nterrupte ur mural, Bla nc Cassé WSK-21 Wall Switch Kit, Whi te / Module d'interrupteur mural, Blanc WSK-21-W
Conversion Kit NG / Module de conversion GN Conversion Kit LP / Module de conversion PL
PRE 2344 POST 2344 PRE 1288 POST 1288
11
NGK-75TR NGK-75TRS LPK-75TR LPK-75TRS
Service Parts
SL-750TRFL (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
6
2
1
4
5
3
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
8
7
12
SL-750TRFL (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
STANDING PILOT IGNITION / ALLUMAGE UNE VEILLEUSE
SERIAL # /
N° DE SÉRI E
PART NUMBER
/ N° DE P IÈCE
ON/OFF Rocke r S wi tch / Interrupteur à bascule marche /arrêt 060-511 Piezo Ignitor / Allumage P iézo 418-513
Burner Tube / Tube de brûleur 477-301A 1 Burner Orifice NG (#42A) / Orifice de brûleur GN (#42A) 060-800 1 Burner Orifice LP (#53A) / Orifice de brûleur PL (#53A) 060-801
2 B ur ne r N G / Brûle ur G N 560-231A 2 Bur ne r L P / Brûleur PL 530-233A 3 Glass Door Assembly / Porte en verre GLA-750 4 Log Grate / Grille de Bûche 538-361A 5 Base Refractory / Réfrac ta i r e Bas e SRV530-339 6 Hood / Hotte SRV530-175 7 Log Set Assembly / Module de Jeu de Bûches LOGS-750ALT 8 Junction Box / Boîtier de raccordement 100-250A
Valve NG / Va lve GN 060-520
Valve LP / Valve PL 060-521
Pilot Assembly NG / Module de veilleuse GN 485-510A
Pilot Assembly LP / Module de veilleuse PL 485-511A
Pilot Orifice NG / Orifice de veilleuse GN 446-505
Pilot Orifice LP / Orifice de veilleuse PL 446-517
Thermocouple / Thermocouple 446-511
Thermopile / Thermopile 060-512
Pilot Tube / Tube de veilleuse SRV485-301
AC CE S SOR IES / ACCESS OIRE S
Fan Kit / Module de ventilateur GFK-160A
Extended Vertical Baffle Kit / Module de verticale étendu le déflecteur BA F-VERT
Wall Switch Kit, Off-white / Module d'interrupteur mural, Blanc Cassé WSK-21
Wall Switch Kit, White / Module d'interrupteur mural, Blanc WSK-21-W
Conversion K it NG / Module de conversion GN NGK-75TR
Conversion K it LP / Module de conversion PL LP K-75TR
13
Service Parts
SL-950TR and SL-950TR-DSI (NG, LP) Exploded Parts Diagram / (GN, PL) Vue éclatée des pièces
4
6
5
3
13
10
Part number list on following page.
*
La liste des numéros de pièce se trouve à la page suivante.
*
14
2
15
1
12
7
8
9
11
14
SL-950TR and SL-950TR-DSI (NG, LP) Service Parts List / Liste des pièces de rechange
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
STANDING PILOT AND DSI IGNITION/
UNE VEILLEUSE ET ALLUMAGE DSI
SERIAL # / N° DE
SÉRIE
PART NUMBER
/ N° DE PIÈCE
ON/OFF Rocker Switch / Interrupteur à bascule marche/arrêt 060-511
Burner Tube / Tub e de brûle ur 4 77-301A
1 Burner Orifice NG (#36A) / Orifice de brûleur GN (#36A) 079-831
1 Burner Orifice LP (#51A) / Orifice de brûleur PL (#51A) 079-803 2 B ur ner N G / Brûle ur G N 560-231A 2 B ur ner LP / Br ûleur PL 560-233A 3 Glass Door Assembly / Po rte en verre GLA-950
4 Log Grate / Grille de B ûche 56 0-360A
5 Base Refractory NG / Réfr ac t a ir e Base G N 5 Base Refractory LP / Réfr ac t ai r e Bas e PL
PRE 4196 POST 4196
PRE 1119 POST 1119
SRV560-337 SRV560-339
SRV560-337 SRV560-339
6 Hood / Hotte SRV560-175 7 Log S et Assembly / Module de Jeu de Bûches LOGS-950 8 Log 1 / Bûche 1 SRV530-711 9 Log 2 / Bûche 2 SRV402-701
10 Log 3 / Bûche 3 SRV560-703 11 Log 4 / Bûche 4 SRV560-702 12 Log 5 / Bûche 5 SRV560-704 13 Log 6 / Bûche 6 SRV569-707
STANDING PILOT IGNITION ONLY / D’ALLUMAGE PAR VEILLEUSE SEULEMENT
Piezo Ignitor / Allumage Piézo 418 -513
14 Junction Box / Boîtier de raccordement 100-250A
Valve NG / Valve GN 060-520 Valve LP / Valve PL 06 0-521 Pilot Assembly NG / Module de veilleuse GN 485-510A Pilot Assembly L P / Module d e veilleuse PL 485-511A Pilot Orifice NG / Orifice de veilleuse GN 446-505 Pilot Orifice LP / Orifice de veilleuse PL 446-517
Thermocouple / Thermocouple 4 46-511 Thermopile / Thermopile 060-512
Pilot Tube / Tube de veilleuse 485-301
DSI IGNITION ONLY / ALLUMAGE DSI SEULEMENT
14 Junction Box / Boîtier de raccordement 100-254A
15 Valve A ssembly -DS I NG / Module de Valve-DS I GN 550-007A
15 Valve Assembly -DSI LP / Module de Valve-DS I PL 55 0-008A
DSI Valve NG / DSI Valve GN 492-500 DSI Valve LP / DSI Valve PL 492-501 Ignito r / Allumag e 501-591 Module / Module 50 1-592
ACCESSOR IES / ACCESSOIRES
Fan Kit / Module de ventilateur GFK-160A Extended Vertical Baffle K it / Module de verticale étendu le déflecteur BAF-VE RT
Wall Switch Ki t, Off-white / Module d'interrupte ur mural, B lanc Cassé WSK -21 Wall Switch Ki t, White / Module d'interrup teur mural, Blanc WSK -21-W
C onvers ion K it NG ( Sta nd ing Pilo t O nly)
/ Modules de conversion GN (allumage une veilleuse seulement)
Conversion K it LP (Standing P ilot Only)
/ Modules de conversion PL (allumage une veilleuse seulement)
NGK-95TR LPK-95TR
15
1
Approvals and Codes
Appliance Certification
The Heat-N-Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed
by the applicable laboratories.
Certification
MODELS: SL-950TR, SL-750TR, SL-750TRFL,
SL-750TRS, SL-550TR, SL-550TRS
LABORATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace Heater STANDARD: ANSI Z21.88CSA2.33
NOTE: THESE MODELS ARE UL LISTED TO UL307B, THE STANDARD FOR GAS-BURNING HEATING APPLI­ANCES FOR MANUFACTURED HOMES AND RECRE-
ATIONAL VEHICLES.
Installation Codes
The fireplace installation must conform to local codes. Before installing the fireplace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections.
High Altitude Installations
U.L. Listed gas fireplaces are tested and approved for elevations from 0 to 2,000 feet in the U.S.A. and from 0 to 4,500 feet in Canada.
When installing this fireplace at an elevation above 2,000 feet (in the United States), it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input should be reduced four percent (4%) for each 1,000 feet above sea level, unless the heating value of the gas has been reduced, in which case this general rule will not apply. To identify the proper orifice size, check with the local gas utility.
When installing this fireplace at an elevation between 2,000 and 4,500 feet (in Canada), the input rating must be reduced by ten percent (10%).
When installing this fireplace at an elevation above 4,500 feet (in Canada), check with local authorities.
Consult your local gas utility for assistance in determining the proper orifice for your location.
In the absence of local codes, the fireplace installation must conform to the National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA-B149 Installation Codes (in Canada). The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes with the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the CSA C22.1 Canadian Electric Code (in Canada).
These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.
Heat-N-Glo Quality Systems registered by SGS ICS
16
Loading...
+ 36 hidden pages